Experimental and numerical investigations of S700 high strength steel tubular section stub columns after exposure to elevated temperatures

被引:28
|
作者
Zhong, Yukai [1 ]
Tan, Kang Hai [1 ]
Zhao, Ou [1 ]
机构
[1] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore, Singapore
关键词
Compression tests; Design standards; Initial local geometric imperfection measurements; Material testing; Numerical modelling; Post-fire; S700 high strength steel tubular sections; Stub columns; POSTFIRE MECHANICAL-PROPERTIES; STRUCTURAL-STEEL; PERFORMANCE; CORROSION; Q690; S690;
D O I
10.1016/j.tws.2021.107669
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper reports comprehensive experimental and numerical investigations into the cross-sectional behaviour and residual resistances of S700 high strength steel square and rectangular hollow section stub columns after exposure to elevated temperatures. The experimental investigation employed three cold-formed S700 high strength steel square and rectangular hollow sections, and for each cross-section, five geometrically identical stub column specimens were prepared and tested after exposure to different levels of elevated temperature, namely 30 degrees C, 400 degrees C, 600 degrees C, 800 degrees C and 1000 degrees C. This was followed by a numerical investigation, where finite element models were initially developed and validated against the experimental results and then adopted to conduct parametric studies to generate further numerical data over a wide range of cross-section dimensions. Owing to the absence of design standards for high strength steel structures after exposure to elevated temperatures, the corresponding ambient temperature design rules, as provided in the European code, American specification and Australian standard, were evaluated for their applicability to S700 high strength steel square and rectangular hollow section stub columns after exposure to elevated temperatures. The evaluation results indicated that the ambient temperature slenderness limits for internal plate elements in compression, as specified in the three considered design standards, are accurate and safe when used for cross-section classification of S700 high strength steel square and rectangular hollow section stub columns after exposure to elevated temperatures. In terms of the cross-section compression resistance predictions, the Australian standard was shown to provide accurate, consistent and safe predicted resistances for S700 high strength steel square and rectangular hollow section stub columns after exposure to different levels of elevated temperature. The European code and American specification were found to yield accurate, consistent and safe post-fire compression resistance predictions for S700 high strength steel non-slender square and rectangular hollow section stub columns but over-predict the post-fire compression resistances for those slender section stub columns, owing principally to the employment of unsafe effective width expressions.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Experimental and numerical investigations into S960 ultra-high strength steel welded I-section stub columns after exposure to elevated temperatures
    Su, Andi
    Jiang, Ke
    Wang, Yuyin
    Zhao, Ou
    THIN-WALLED STRUCTURES, 2023, 183
  • [2] Structural Response and Residual Capacity of S700 High-Strength Steel CHS Columns after Exposure to Elevated Temperatures
    Zhong, Yukai
    Sun, Yao
    Zhao, Ou
    Gardner, Leroy
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (06)
  • [3] Experimental and numerical investigation of S700 high strength steel CHS beam-columns after exposure to fire
    Zhong, Yukai
    Zhao, Ou
    Gardner, Leroy
    THIN-WALLED STRUCTURES, 2022, 175
  • [4] Post-fire behaviour and residual resistances of S700 high strength steel tubular section stub columns under combined loading
    Zhong, Yukai
    Sun, Yao
    Hai, Kang
    Tan, Hai
    Zhao, Ou
    THIN-WALLED STRUCTURES, 2021, 169
  • [5] Experimental investigation of square stainless steel tubular stub columns after elevated temperatures
    He, Kang
    Chen, Yu
    Han, Shaohua
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 159 : 397 - 414
  • [6] Experimental investigation of square concrete filled stainless steel tubular stub columns after exposure to elevated temperatures
    Chen, Yu
    He, Kang
    Han, Shaohua
    Wei, Jiangang
    THIN-WALLED STRUCTURES, 2018, 130 : 12 - 31
  • [7] The response of high strength S700 MC steel after fire exposure
    Zeybek, Ozer
    Polat, Veysel
    Ozkilic, Yasin Onuralp
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 219
  • [8] Experimental and numerical investigations of S890 and S960 ultra-high strength steel circular hollow section stub columns after fire exposure
    Zhang, Jiahao
    Yang, Hua
    Su, Andi
    Jiang, Ke
    THIN-WALLED STRUCTURES, 2025, 209
  • [9] Experimental and Numerical Investigations of Octagonal High-Strength Steel Tubular Stub Columns under Combined Compression and Bending
    Fang, Han
    Chan, Tak-Ming
    Young, Ben
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (01)
  • [10] Experimental studies on mechanical properties of S700 MC steel at elevated temperatures
    Shakil, Saani
    Lu, Wei
    Puttonen, Jari
    FIRE SAFETY JOURNAL, 2020, 116 (116)