Effect of simulated refractive error on adult visual acuity for paediatric tests
被引:7
|
作者:
论文数: 引用数:
h-index:
机构:
Paudel, Nabin
[1
]
Jacobs, Robert J.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Auckland, Fac Med & Hlth Sci, Sch Optometry & Vis Sci, Auckland, New ZealandUniv Auckland, Fac Med & Hlth Sci, Sch Optometry & Vis Sci, Auckland, New Zealand
Jacobs, Robert J.
[1
]
Sloan, Rebecca
论文数: 0引用数: 0
h-index: 0
机构:
Univ Auckland, Fac Med & Hlth Sci, Sch Optometry & Vis Sci, Auckland, New ZealandUniv Auckland, Fac Med & Hlth Sci, Sch Optometry & Vis Sci, Auckland, New Zealand
Sloan, Rebecca
[1
]
Denny, Sarah
论文数: 0引用数: 0
h-index: 0
机构:
Univ Auckland, Fac Med & Hlth Sci, Sch Optometry & Vis Sci, Auckland, New ZealandUniv Auckland, Fac Med & Hlth Sci, Sch Optometry & Vis Sci, Auckland, New Zealand
Denny, Sarah
[1
]
Shea, Kimberley
论文数: 0引用数: 0
h-index: 0
机构:
Univ Auckland, Fac Med & Hlth Sci, Sch Optometry & Vis Sci, Auckland, New ZealandUniv Auckland, Fac Med & Hlth Sci, Sch Optometry & Vis Sci, Auckland, New Zealand
Shea, Kimberley
[1
]
Thompson, Benjamin
论文数: 0引用数: 0
h-index: 0
机构:
Univ Auckland, Fac Med & Hlth Sci, Sch Optometry & Vis Sci, Auckland, New Zealand
Univ Waterloo, Sch Optometry & Vis Sci, Waterloo, ON, CanadaUniv Auckland, Fac Med & Hlth Sci, Sch Optometry & Vis Sci, Auckland, New Zealand
Thompson, Benjamin
[1
,2
]
Anstice, Nicola
论文数: 0引用数: 0
h-index: 0
机构:
Univ Auckland, Fac Med & Hlth Sci, Sch Optometry & Vis Sci, Auckland, New ZealandUniv Auckland, Fac Med & Hlth Sci, Sch Optometry & Vis Sci, Auckland, New Zealand
Anstice, Nicola
[1
]
机构:
[1] Univ Auckland, Fac Med & Hlth Sci, Sch Optometry & Vis Sci, Auckland, New Zealand
[2] Univ Waterloo, Sch Optometry & Vis Sci, Waterloo, ON, Canada
PurposeAlthough vanishing optotype preferential-looking tasks are commonly used to measure visual acuity (VA), the relative sensitivity of these tests to refractive error is not well understood. To address this issue, we determined the effect of spherical and astigmatic simulated refractive errors on adult VA measures obtained using vanishing optotypes, picture optotypes and Sloan letters. MethodsVA was determined uniocularly for adults under conditions of spherical (0.0-3.0 DS; n=23) and astigmatic (0.0-3.0 DC at 90 degrees and 180 degrees; n=20) defocus using the Cardiff Acuity Test (vanishing optotypes), crowded linear Lea Symbols (picture-optotype recognition task) and the Early Treatment of Diabetic Retinopathy Study (ETDRS) letter chart. ResultsThe Cardiff Acuity Test over-estimated VA compared with the Lea Symbols and ETDRS charts in both focused and defocused conditions. The mean difference between the Cardiff Acuity Test and the ETDRS chart was 0.31 logMAR (95% limits of agreement (LOA) 0.10-0.52 logMAR) in focused conditions and 0.64 logMAR (95% LOA 0.25-1.05 logMAR) with 3D of spherical defocus. Defocus degraded VA on all charts, however there was a significant chart-by-defocus interaction whereby the Cardiff Acuity Test was more resistant to the effects of both spherical (P<0.0001) and cylindrical (P<0.001) optical defocus than the recognition acuity tasks at all defocus levels. ConclusionAlthough the Cardiff Acuity Test provides an easy method for VA measurement in infants and toddlers, there is a considerable overestimation of VA compared with recognition acuity tasks particularly in the presence of defocus. A simple correction factor (of for example three lines overestimate) cannot be applied to Cardiff acuity measures as there is increasing over-estimation of VA with increasing defocus. Infants with significant refractive error may fall within normal visual acuity ranges for the Cardiff Acuity Test.
机构:
Hong Kong Polytech Univ, Sch Optometry, Kowloon, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Sch Optometry, Kowloon, Hong Kong, Peoples R China
Cheung, Sin Wan
Cho, Pauline
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Polytech Univ, Sch Optometry, Kowloon, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Sch Optometry, Kowloon, Hong Kong, Peoples R China
Cho, Pauline
Chui, Wan Sang
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Polytech Univ, Sch Optometry, Kowloon, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Sch Optometry, Kowloon, Hong Kong, Peoples R China
Chui, Wan Sang
Woo, George C.
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Polytech Univ, Sch Optometry, Kowloon, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Sch Optometry, Kowloon, Hong Kong, Peoples R China