Development of an in vivo tissue-engineered, autologous heart valve (the biovalve): Preparation of a prototype model

被引:60
|
作者
Hayashida, Kyoko
Kanda, Keiichi
Yaku, Hitoshi
Ando, Joji
Nakayama, Yasuhide
机构
[1] Natl Cardiovasc Ctr, Inst Res, Dept Bioengn, Adv Med Engn Ctr, Osaka 5658565, Japan
[2] Kyoto Prefectural Univ Med, Dept Cardiovasc Surg, Kyoto, Japan
[3] Univ Tokyo, Grad Sch Med, Dept Biomed Engn, Syst Physiol Lab, Tokyo 106, Japan
[4] Hokkaido Univ, Grad Sch Engn, Div Biotechnol & Macromol chem, Sapporo, Hokkaido 060, Japan
来源
关键词
D O I
10.1016/j.jtcvs.2007.01.087
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study aimed to develop an autologous heart valve without using traditional in vitro tissue-engineering methods, which necessitate complicated cell management protocols under exceptionally clean laboratory facilities. Methods: An autologous heart valve construct composed of trileaflets was prepared using a specially designed mold. The mold was prepared by covering a silicone rod with a crown-shaped tubular polyurethane scaffold containing 3 horns. The mold was implanted in the dorsal subcutaneous space in Japan White rabbits for 4 weeks. After harvesting, the implanted trileaflet valve-shaped structure with an internal diameter of either 5 or 20 mm was obtained by trimming the membranous tissue formed between the horns located around the silicone rod. The valve substitute was examined both macroscopically and histologically. The tensile strength of the leaflets was measured to rupture. The degree of regurgitation in valve function was evaluated using a flow circuit by calculating the ratio of the regurgitation volume to the forward flow volume. Results: After implantation, the mold was completely covered with connective tissue consisting mostly of collagen and fibroblasts. Harvesting of the mold was straightforward, because there was little adhesion between the formed tissue and the native skin tissue. The trileaflet heart valve construct was obtained after withdrawing the inserted rods and trimming the membranous tissues formed between the horns of the scaffold. It was firmly attached to the scaffold, the interstices and surface of which revealed connective tissues composed of components similar to those of the leaflet tissue. Although the mechanical properties of the leaflet tissue were less efficient than those of the native porcine aortic valve leaflets, satisfactory valvular functions were demonstrated under pulsatile conditions using a flow circuit. No regurgitation was observed under retrograde hydrostatic pressures of up to 60 mm Hg, the physiologic pressure acting on the aortic valves during retrograde aortic flow. Conclusions: The biovalve, an autologous, in vivo tissue-engineered, trileaflet, valve-shaped construct, was developed using our novel in-body tissue architecture technology. The biovalve has the potential to be an ideal prosthetic heart valve, with excellent biocompatibility to the growth of the recipient's heart.
引用
收藏
页码:152 / 159
页数:8
相关论文
共 50 条
  • [1] Development of in vivo tissue-engineered conduit valve as the next generation of "biovalve"
    Hayashida, K
    Kanda, K
    Yaku, H
    Nakayama, Y
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2006, 29 (05): : 509 - 509
  • [2] In vivo tissue-engineered, autologous, valved conduit "Biovalve" with robust wall tissues
    Funayama, M.
    Furukoshi, M.
    Moriwaki, T.
    Nakayama, Y.
    EUROPEAN HEART JOURNAL, 2015, 36 : 957 - 957
  • [3] In vivo evaluation of an in-body, tissue-engineered, completely autologous valved conduit (biovalve type VI) as an aortic valve in a goat model
    Yoshiaki Takewa
    Masashi Yamanami
    Yuichiro Kishimoto
    Mamoru Arakawa
    Keiichi Kanda
    Yuichi Matsui
    Tomonori Oie
    Hatsue Ishibashi-Ueda
    Tsutomu Tajikawa
    Kenkichi Ohba
    Hitoshi Yaku
    Yoshiyuki Taenaka
    Eisuke Tatsumi
    Yasuhide Nakayama
    Journal of Artificial Organs, 2013, 16 : 176 - 184
  • [4] In vivo evaluation of an in-body, tissue-engineered, completely autologous valved conduit (biovalve type VI) as an aortic valve in a goat model
    Takewa, Yoshiaki
    Yamanami, Masashi
    Kishimoto, Yuichiro
    Arakawa, Mamoru
    Kanda, Keiichi
    Matsui, Yuichi
    Oie, Tomonori
    Ishibashi-Ueda, Hatsue
    Tajikawa, Tsutomu
    Ohba, Kenkichi
    Yaku, Hitoshi
    Taenaka, Yoshiyuki
    Tatsumi, Eisuke
    Nakayama, Yasuhide
    JOURNAL OF ARTIFICIAL ORGANS, 2013, 16 (02) : 176 - 184
  • [5] Development of in vivo, Tissue-Engineered, Autologous, 3D Heart Valvular Tissue, Type SC Biovalve With Excellent Mechanical Properties, Valular Functions, and in vivo Performances
    Nakayama, Yasuhide
    Takewa, Yoshiaki
    Moriwaki, Takeshi
    Sumikura, Hirohito
    Miyamoto, Shinji
    Okamoto, Keitaro
    Funayama, Marina
    Furukoshi, Maya
    Tatsumi, Eisuke
    CIRCULATION, 2015, 132
  • [6] A NOVEL AUTOLOGOUS TISSUE-ENGINEERED HEART VALVE FOR TRANSCATHETER IMPLANTATION
    Takewa, Y.
    Nakayama, Y.
    Shimamura, J.
    Tatsumi, E.
    CARDIOLOGY, 2018, 140 : 171 - 171
  • [7] IN-BODY TISSUE-ENGINEERED AND COMPLETELY AUTOLOGOUS AORTIC VALVED CONDUIT (BIOVALVE) IN A GOAT MODEL
    Takewa, Y.
    Nakayama, Y.
    Yamanami, M.
    Hanada, S.
    Umeki, A.
    Matsui, Y.
    Kanda, K.
    Yaku, H.
    Tajikawa, T.
    Ohba, K.
    Taenaka, Y.
    Tatsumi, E.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (08): : 642 - 642
  • [8] Architecture of an in vivo-tissue engineered autologous conduit "Biovalve"
    Hayashida, Kyoko
    Kanda, Keiichi
    Oie, Tomonori
    Okamoto, Yoshihiro
    Ishibashi-Ueda, Hatsue
    Onoyama, Masaaki
    Tajikawa, Tsutomu
    Ohba, Kenkichi
    Yaku, Hitoshi
    Nakayama, Yasuhide
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 86B (01) : 1 - 8
  • [9] Preparation of in-vivo tissue-engineered valved conduit with the sinus of Valsalva (type IV biovalve)
    Masashi Yamanami
    Yuki Yahata
    Tsutomu Tajikawa
    Kenkichi Ohba
    Taiji Watanabe
    Keiichi Kanda
    Hitoshi Yaku
    Yasuhide Nakayama
    Journal of Artificial Organs, 2010, 13 : 106 - 112
  • [10] Successful Aortic Valve Implantation Using an In-Body Tissue-Engineered, Completely Autologous Valved Conduit (BIOVALVE) in a Goat Model
    Takewa, Yoshiaki
    Nakayama, Yasuhide
    Yamanami, Masashi
    Umeki, Akihide
    Matsui, Yuichi
    Kanda, Keiichi
    Yaku, Hitoshi
    Tajikawa, Tsutomu
    Ohba, Kenkichi
    Taenaka, Yoshiyuki
    Tatsumi, Eisuke
    CIRCULATION, 2011, 124 (21)