Exploiting automatic on-line renewable molecularly imprinted solid-phase extraction in lab-on-valve format as front end to liquid chromatography: application to the determination of riboflavin in foodstuffs

被引:29
|
作者
Oliveira, Hugo M. [1 ]
Segundo, Marcela A. [1 ]
Lima, Jose L. F. C. [1 ]
Miro, Manuel [2 ]
Cerda, Victor [2 ]
机构
[1] Univ Porto, REQUIMTE, Serv Quim Fis, Fac Farm, P-4099030 Oporto, Portugal
[2] Univ Balearic Isl, Dept Chem, Fac Sci, Palma De Mallorca 07122, Illes Balears, Spain
关键词
Solid-phase extraction; Molecularly imprinted polymer; Flow analysis; Lab-on-valve; Riboflavin; Foodstuff; WATER-SOLUBLE VITAMINS; BEAD-INJECTION; TRACE LEVELS; CAPILLARY-ELECTROPHORESIS; FLUORESCENCE DETECTION; MASS-SPECTROMETRY; SAMPLE TREATMENT; POLYMERS; MILK; PRECONCENTRATION;
D O I
10.1007/s00216-010-3522-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present work, it is proposed, for the first time, an on-line automatic renewable molecularly imprinted solid-phase extraction (MISPE) protocol for sample preparation prior to liquid chromatographic analysis. The automatic microscale procedure was based on the bead injection (BI) concept under the lab-on-valve (LOV) format, using a multisyringe burette as propulsion unit for handling solutions and suspensions. A high precision on handling the suspensions containing irregularly shaped molecularly imprinted polymer (MIP) particles was attained, enabling the use of commercial MIP as renewable sorbent. The features of the proposed BI-LOV manifold also allowed a strict control of the different steps within the extraction protocol, which are essential for promoting selective interactions in the cavities of the MIP. By using this on-line method, it was possible to extract and quantify riboflavin from different foodstuff samples in the range between 0.450 and 5.00 mg L-1 after processing 1,000 mu L of sample (infant milk, pig liver extract, and energy drink) without any prior treatment. For milk samples, LOD and LOQ values were 0.05 and 0.17 mg L-1, respectively. The method was successfully applied to the analysis of two certified reference materials (NIST 1846 and BCR 487) with high precision (RSD<5.5%). Considering the downscale and simplification of the sample preparation protocol and the simultaneous performance of extraction and chromatographic assays, a cost-effective and enhanced throughput (six determinations per hour) methodology for determination of riboflavin in foodstuff samples is deployed here.
引用
收藏
页码:77 / 86
页数:10
相关论文
共 50 条
  • [1] Exploiting automatic on-line renewable molecularly imprinted solid-phase extraction in lab-on-valve format as front end to liquid chromatography: application to the determination of riboflavin in foodstuffs
    Hugo M. Oliveira
    Marcela A. Segundo
    José L. F. C. Lima
    Manuel Miró
    Victor Cerdà
    Analytical and Bioanalytical Chemistry, 2010, 397 : 77 - 86
  • [2] Automated on-line renewable solid-phase extraction-liquid chromatography exploiting multisyringe flow injection-bead injection lab-on-valve analysis
    Quintana, JB
    Miró, M
    Estela, JM
    Cerdà, V
    ANALYTICAL CHEMISTRY, 2006, 78 (08) : 2832 - 2840
  • [3] Development of an on-line lab-on-valve micro-solid phase extraction system coupled to liquid chromatography for the determination of flavonoids in citrus juices
    Subhi Sammani, Mohamad
    Clavijo, Sabrina
    Gonzalez, Alba
    Cerda, Victor
    ANALYTICA CHIMICA ACTA, 2019, 1082 (56-65) : 56 - 65
  • [4] Determination of tetracycline residues in lake water by on-line coupling of molecularly imprinted solid-phase extraction with high performance liquid chromatography
    Liu, Meijiao
    Li, Yongna
    Lin, Shen
    Dong, Xiangchao
    ANALYTICAL METHODS, 2014, 6 (23) : 9446 - 9452
  • [5] Critical comparison of the on-line and off-line molecularly imprinted solid-phase extraction of patulin coupled with liquid chromatography
    Lhotska, Ivona
    Holznerova, Anezka
    Solich, Petr
    Satinsky, Dalibor
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (23) : 4599 - 4609
  • [6] On-line renewable solid-phase extraction hyphenated to liquid chromatography for the determination of UV filters using bead injection and multisyringe-lab-on-valve approach
    Oliveira, Hugo M.
    Segundo, Marcela A.
    Lima, Jose L. F. C.
    Miro, Manuel
    Cerda, Victor
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (22) : 3575 - 3582
  • [7] Molecularly imprinted on-line solid-phase extraction combined with chemiluminescence for the determination of pazufloxacin mesilate
    Yang, Chunyan
    Zhang, Zhujun
    Chen, Suming
    Yang, Feng
    MICROCHIMICA ACTA, 2007, 159 (3-4) : 299 - 304
  • [8] Molecularly imprinted on-line solid-phase extraction combined with chemiluminescence for the determination of pazufloxacin mesilate
    Chunyan Yang
    Zhujun Zhang
    Suming Chen
    Feng Yang
    Microchimica Acta, 2007, 159 : 299 - 304
  • [9] On-line molecularly imprinted solid-phase extraction for the selective spectrophotometric determination of nicotine in the urine of smokers
    Figueiredo, Eduardo Costa
    de Oliveira, Daniela Mayra
    Pereira Bastos de Siqueira, Maria Elisa
    Zezzi Arruda, Marco Aurelio
    ANALYTICA CHIMICA ACTA, 2009, 635 (01) : 102 - 107
  • [10] Study on an on-line molecularly imprinted solid-phase extraction coupled to high-performance liquid chromatography for separation and determination of trace estrone in environment
    Xu, Zhixiang
    Chen, Shuang
    Huang, Wei
    Fang, Guozhen
    Hua Pingzhu
    Wang, Shuo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (04) : 1273 - 1279