Performance evaluation of a cool roof model in composite climate

被引:12
|
作者
Rawat, Mohan [1 ]
Singh, R. N. [1 ]
机构
[1] Devi AhilyaVishwavidyalaya, Sch Energy & Environm Studies, Indore 452001, Madhya Pradesh, India
关键词
Building Envelope; Composite Climate; Cool Roof; Reinforced Cement Concrete; Thermal Comfort; BUILDINGS; EFFICIENCY; REDUCTION;
D O I
10.1016/j.matpr.2020.12.858
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
India is the seventh-largest country in the world and ranked second with more than a billion populations after China. The annual electricity consumption demand increased to 8% in the buildings for residential and commercial sectors. The requirement of thermal comfort is a primary need in residential buildings located in composite and hot-dry climates. The thermal performance of cool roof model was analyzed in terms of indoor temperature compared to Reinforced Cement Concrete (RCC) roof for composite climate, Indore, Madhya Pradesh, India. The study aims to assess the impact of the cool roof on the indoor temperature of buildings. The experimental study indicates that a cool roof performed better for indoor temperature profile and maintains a thermal comfort in buildings. The cool roof technology is more economical and easy to implement in all residential and commercial buildings. The study revealed that the roof?s interior and exterior surface temperature reduced about 4.1 ?C and 9.2 ?C, respectively, while indoor room temperature reduced about 2.4 ?C. ? 2020 Elsevier Ltd. All rights reserved. Selection and peer-review under responsibility of the scientific committee of the International Conference on Advances in Materials Processing & Manufacturing Applications.
引用
收藏
页码:4956 / 4960
页数:5
相关论文
共 50 条
  • [1] Thermal performance of building prototype with different cool roof structures in composite climate
    Rawat, Mohan
    Singh, R. N.
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2022, 41 (10) : 1434 - 1465
  • [2] Performance evaluation of a metamaterial-based new cool roof using improved Roof Thermal Transfer Value model
    Fang, Hong
    Zhao, Dongliang
    Yuan, Jinchao
    Aili, Ablimit
    Yin, Xiaobo
    Yang, Ronggui
    Tan, Gang
    APPLIED ENERGY, 2019, 248 : 589 - 599
  • [3] Modelling of cool roof performance for double-skin roofs in tropical climate
    Zingre, Kishor T.
    Wan, Man Pun
    Wong, Swee Khian
    Toh, Winston Boo Thian
    Lee, Irene Yen Leng
    ENERGY, 2015, 82 : 813 - 826
  • [4] Modeling of cool roof heat transfer in tropical climate
    Zingre, Kishor T.
    Wan, Man Pun
    Tong, Shanshan
    Li, Hua
    Chang, Victor W. -C.
    Wong, Swee Khian
    Toh, Winston Boo Thian
    Lee, Irene Yen Leng
    RENEWABLE ENERGY, 2015, 75 : 210 - 223
  • [5] Above -roof air temperature effects on HVAC and cool roof performance: Experiments and development of a predictive model
    Green, Alan
    Gomis, Laia Ledo
    Paolini, Riccardo
    Haddad, Shamila
    Kokogiannakis, Georgios
    Cooper, Paul
    Ma, Zhenjun
    Kosasih, Buyung
    Santamouris, Mattheos
    ENERGY AND BUILDINGS, 2020, 222
  • [6] Evaluation of clay tile roofing as a cool roof
    Rachi, Rintaro
    Miyazaki, Hiroshi
    Technology Reports of Kansai University, 2015, (57): : 75 - 80
  • [7] Experimental comparison of summer thermal performance of green roof (GR), double skin roof (DSR) and cool roof (CR) in lightweight rooms in subtropical climate
    Meng, Erlin
    Yang, Jiawang
    Cai, Ruonan
    Zhou, Bo
    Wang, Junqi
    JOURNAL OF BUILDING PHYSICS, 2022, 45 (06) : 809 - 832
  • [8] A detailed investigation on thermal performance and energy savings of cool roof systems for composite climates of India
    Kulkarni, Kishor S.
    Singh, Garima
    Premi, Renu
    ADVANCES IN BUILDING ENERGY RESEARCH, 2024, 18 (05) : 453 - 474
  • [9] Integrated Evaluation of the Performance of Composite Cool Thermal Insulation Materials
    Antoniadou, P.
    Giama, E.
    Boemi, S. -N.
    Karlessi, Th.
    Santamouris, M.
    Papadopoulos, A. M.
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 1581 - 1586
  • [10] Evaluation of the pull-out strength of connections with roof cladding using honeycomb panels with cool roof performance capacity
    Sang-Woo Park
    In-Ho Lee
    Kwang-Il Ko
    E. T. Lee