Hydrogen and D/H analysis of apatite by Elemental Analyzer-Chromium/High-Temperature Conversion-Isotope Ratio Mass Spectrometry (EA-Cr/HTC-IRMS)

被引:9
|
作者
Greenwood, James P. [1 ]
机构
[1] Wesleyan Univ, Dept Earth & Environm Sci, 265 Church St, Middletown, CT 06459 USA
基金
美国国家科学基金会;
关键词
Apatite; Hydrogen isotopes; SIMS; TC/EA; HTC; Adsorbed moisture; PHOSPHATE MINERALS; LUNAR APATITE; WATER; MOON; CHONDRITE; INSIGHTS; SAMPLES; FLUORAPATITE; METAMORPHISM; METEORITES;
D O I
10.1016/j.chemgeo.2018.09.029
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Hydrogen and delta D measurements of the mineral apatite have been used to measure volatile contents of planets and planetesimals and to infer the sources and evolution of water throughout the solar system. All of these studies use Secondary Ion Mass Spectrometry (SIMS) which necessitates the use of apatite mineral standards to correct for matrix effects, which have previously been measured by mass spectrometry for hydrogen isotopes. Here we present a new technique of Elemental Analyzer-Chromium/High Temperature Conversion-Isotope Ratio Mass Spectrometry (EA-Cr/HTC-IRMS) for the measurement of hydrogen and hydrogen isotopes of apatite. This technique presents greater technical advantages over TC/EA due to ability of chromium to bind with phosphorus in the high-temperature reactor, and prevent this elemental P from clogging the instrument components. We also show that removal of adsorbed moisture of nominally hydrous minerals and glasses becomes increasingly important with decreasing grain size of materials and present experiments on moisture removal from nominally anhydrous quartz. We report hydrogen and hydrogen isotope results of five fluorapatite and two hydroxylapatite samples, including Durango apatite. We show that our results of hydrogen content of Durango apatite are similar to published values using the TC/EA technique. Our recommended values for hydrogen using a Cr reactor for H2O and delta DVSMOW-SLAP for Durango apatite are 608 +/- 102 ppm H2O and delta DVSMOW-SLAP = - 86 +/- 4% (2 sigma).
引用
收藏
页码:175 / 181
页数:7
相关论文
共 16 条
  • [1] Optimization of on-line hydrogen stable isotope ratio measurements of halogen- and sulfur-bearing organic compounds using elemental analyzer-chromium/high-temperature conversion isotope ratio mass spectrometry (EA-Cr/HTC-IRMS)
    Gehre, Matthias
    Renpenning, Julian
    Geilmann, Heike
    Qi, Haiping
    Coplen, Tyler B.
    Kuemmel, Steffen
    Ivdra, Natalija
    Brand, Willi A.
    Schimmelmann, Arndt
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (06) : 475 - 484
  • [2] Stable isotope analysis of non-exchangeable hydrogen in carbohydrates derivatised with N-methyl-bis-trifluoroacetamide by gas chromatography - Chromium silver reduction/High temperature Conversion-isotope ratio mass spectrometry (GC-CrAg/HTC-IRMS)
    Abrahim, Aiman
    Cannavan, Andrew
    Kelly, Simon D.
    FOOD CHEMISTRY, 2020, 318
  • [3] Compound-Specific Hydrogen Isotope Analysis of Heteroatom-Bearing Compounds via Gas Chromatography-Chromium-Based High-Temperature Conversion (Cr/HTC)-Isotope Ratio Mass Spectrometry
    Renpenning, Julian
    Kuemmel, Steffen
    Hitzfeld, Kristina L.
    Schimmelmann, Arndt
    Gehre, Matthias
    ANALYTICAL CHEMISTRY, 2015, 87 (18) : 9443 - 9450
  • [4] Oxygen isotope studies of phosphite oxidation: Purification and analysis of reactants and products by high-temperature conversion elemental analyzer/isotope ratio mass spectrometry
    Chang, Sae Jung
    Blake, Ruth E.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (21) : 2039 - 2044
  • [5] Isotope ratio monitoring gas chromatography mass spectrometry of D H by high temperature conversion isotope ratio mass spectrometry
    Hilkert, AW
    Douthitt, CB
    Schlüter, HJ
    Brand, WA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (13) : 1226 - 1230
  • [6] Compound-specific hydrogen isotope analysis of fluorine-, chlorine-, bromine- and iodine-bearing organics using gas chromatography-chromium-based high-temperature conversion (Cr/HTC) isotope ratio mass spectrometry
    Renpenning, Julian
    Schimmelmann, Arndt
    Gehre, Matthias
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (13) : 1095 - 1102
  • [7] High-throughput simultaneous determination of plasma water deuterium and 18-oxygen enrichment using a high-temperature conversion elemental analyzer with isotope ratio mass spectrometry
    Richelle, M
    Darimont, C
    Piguet-Welsch, C
    Fay, LB
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (07) : 795 - 798
  • [8] Stable Nitrogen Isotope Analysis of Amino Acids by Using Gas Chromatography/Isotope Ratio Mass Spectrometry (GC/IRMS) System with High-temperature Combustion Interface
    Kamata, Kyoko
    Chikaraishi, Yoshito
    BUNSEKI KAGAKU, 2014, 63 (03) : 279 - 282
  • [9] High-Precision Oxygen-Isotope Analysis of Iron (Oxyhydr)oxides Using High-Temperature Conversion Isotope Ratio Mass Spectrometry
    Galili, Nir
    Somlyay, Anna
    Aquila, Giorgia
    Wijker, Reto
    Gautschi, Philip
    Wacker, Lukas
    Hemingway, Jordon D.
    ANALYTICAL CHEMISTRY, 2025, 97 (13) : 7002 - 7009
  • [10] [2H/H] isotope ratio analyses of [2H-H5]cholesterol using high-temperature conversion elemental analyser isotope-ratio mass spectrometry:: determination of cholesterol absorption in normocholesterolemic volunteers
    Godin, JP
    Richelle, M
    Metairon, S
    Fay, LB
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (03) : 325 - 330