Adopting a multipurpose inhibitor to control corrosion of ferrous alloys in cooling water systems

被引:56
|
作者
Mahgoub, F. M. [1 ]
Abdel-Nabey, B. A. [2 ]
El-Samadisy, Y. A. [1 ]
机构
[1] Univ Alexandria, Dept Mat Sci, Inst Grad Studies & Res, Alexandria 21526, Egypt
[2] Univ Alexandria, Fac Sci, Dept Chem, Alexandria 21526, Egypt
关键词
Corrosion; Carbon steel; Stainless steel; Organic inhibitors; Pitting corrosion; Potentiodynamic polarization; AUSTENITIC STAINLESS-STEELS; MILD-STEEL; MOLYBDENUM;
D O I
10.1016/j.matchemphys.2009.10.028
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The heterocyclic compounds; 2,5-diphenylpyrazolo[ 1,5-c]pyrimidine-7(6H)thione (Phenyl), 5-methoxyphenyl-2-phenylpyrazolo[1,5-c]pyrimidine-7(6H)thione (Methoxy), 5-tolyl-2-phenylpyrazolo[1,5-c] pyrimidine-7(6H)thione (Tolyl), 5-tolyl-2-phenylpyrazolo[1,5-c]pyrimidine-7(6H)one (Inon), 2,5-diphenyl-3-iodopyrazolo[1,5-c]pyrimidine-7(6H)thione (Iodo) and 2,5-diphenyl-3-bromopyrazolo[1,5c]pyrimidine-7(6H)thione (Bromo) were screened by Tafel Extrapolation and Linear Polarization Resistance techniques to detect the possibility of inhibition the uniform corrosion of carbon steel in stagnant cooling water containing 200ppm chloride at 25 degrees C. The inhibition efficiencies of the studied compounds were found to decrease in the following order: Tolyl > Methoxy > Phenyl > Iodo > Bromo > Inon. The Tolyl compound was proved to be the most efficient inhibitor on carbon steel and therefore trialed on stainless steels 304 and 316 to examine its applicability as a multipurpose inhibitor at the same operating conditions. It was revealed that the Tolyl doses inhibit the pitting corrosion of both the stainless alloys. The Tolyl compound; therefore, functions as true multipurpose corrosion inhibitor for different ferrous alloys in industrial cooling water systems. For example, the percentage inhibition of 10 mmole L-1 of the Tolyl compound is 93.42%, 82.91% and 85.40% for carbon steel, 304SS and 316SS, respectively. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 108
页数:5
相关论文
共 50 条
  • [1] Electromagnetic corrosion control in water cooling systems
    de Souza, Eduardo Alencar
    da Cunha Ponciano Gomes, Jose Antonio
    ANTI-CORROSION METHODS AND MATERIALS, 2014, 61 (03) : 153 - 157
  • [2] CORROSION AND FOULING CONTROL IN COOLING WATER SYSTEMS
    CHAKRABO.S
    ALLARD, B
    KEMISK TIDSKRIFT, 1974, 86 (10): : 52 - &
  • [3] CORROSION CONTROL OF INDUSTRIAL COOLING WATER-SYSTEMS
    BOFFARDI, BP
    MATERIALS PERFORMANCE, 1984, 23 (11) : 17 - 24
  • [4] Development and evaluation of a low chromate corrosion inhibitor for cooling water systems
    Bahadur, A
    CANADIAN METALLURGICAL QUARTERLY, 1998, 37 (05) : 459 - 468
  • [5] Corrosion inhibitor evaluation for materials used in closed cooling water systems
    Moccari, AA
    MATERIALS PERFORMANCE, 1999, 38 (09) : 54 - 59
  • [6] Corrosion inhibitor evaluation for materials used in closed cooling water systems
    Carolina Power and Light, Harris E+E Center, 3239 New Hill-Holleman Road, Newhill, NC 27562, United States
    Mater Perform, 9 (54-59):
  • [7] Improve corrosion and deposition control in alkaline cooling water systems
    Geiger, GE
    HYDROCARBON PROCESSING, 1996, 75 (01): : 93 - 98
  • [8] CONTROL OF CORROSION IN INDUSTRIAL COOLING WATER SYSTEMS - 1.
    Harris, A.
    Marshall, A.
    Corrosion Prevention and Control, 1980, 27 (03): : 18 - 21
  • [9] Plant extracts as green corrosion inhibitor for ferrous metal alloys: A review
    Salleh, Siti Zuliana
    Yusoff, Abdul Hafidz
    Zakaria, Siti Koriah
    Taib, Mustaffa Ali Azhar
    Abu Seman, Anasyida
    Masri, Mohamad Najmi
    Mohamad, Mardawani
    Mamat, Sarizam
    Sobri, Sharizal Ahmad
    Ali, Arlina
    Teo, Pao Ter
    JOURNAL OF CLEANER PRODUCTION, 2021, 304 (304)
  • [10] Corrosion control in cooling water systems: Recent experience using a new corrosion monitor
    Hale, ER
    Yang, B
    Enzien, MV
    CORROSION IN REFINERY PETROCHEMICAL AND POWER GENERATION PLANTS, PROCEEDINGS, 2000, : 367 - 376