Study on Electrical Properties and Field Solutions of Water Related Heating of Composite Insulators on 500kV AC Transmission Lines

被引:0
|
作者
Cheng, Li [1 ]
Zhang, Zhonghao [1 ]
Zhang, Fuzeng [2 ]
Wang, Liming [1 ]
Guan, Zhicheng [2 ]
机构
[1] Tsinghua Univ, Grad Sch Shenzhen, Shenzhen 518055, Peoples R China
[2] Elect Power Res Inst China Southern Power Grid, Guangzhou 510080, Guangdong, Peoples R China
关键词
composite insulators; water; IR results; FEM analysis;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In 2011, a composite insulator in Shenzhen suffered fracture. Through infrared thermal test along the same and neighbor lines, 517 out of 1327 insulators presented with up to or over 0.5 degrees C thermal increase. Early researches demonstrated that humidity was a factor to have effect on heating performance. In order to understand the potential mechanism of heating and provide precaution suggestions, we conducted FEM analysis on both thermal and electrical field; mechanical load test; electrical endurance test; mechanical, microscopic configurational as well as chemical analysis upon 9 problematic insulators and compared several ways to control end side field intensity. Defective interfaces were found. Polarization of insulation material after aging and water penetration was critical to heating. In order to reduce damage, decreasing the end side filed intensity was necessary to lessen heating loss as well as decelerate aging process.
引用
收藏
页码:672 / 675
页数:4
相关论文
共 33 条
  • [1] Investigation on bird damage to composite insulators of 500kV transmission lines
    Investigation on bird damage to composite insulators of 500kV transmission lines
    Liang, X.-M., 2005, Power System Technology Press (29)
  • [2] Electric Field Calculation and Grading Ring Optimization of Composite Insulator for 500kV AC Transmission Lines
    Li, Jing
    Peng, Zongren
    Feng, Yong
    Fu, Xiaoyong
    Xie, Tianxi
    PROCEEDINGS OF THE 2010 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS (ICSD 2010), 2010,
  • [3] Study on pollution flashover characteristic of insulators on 500kV AC transmission lines in high-altitude area
    Huang, Ruiping
    Zhou, Jun
    Xu, Yueneng
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 3306 - 3309
  • [4] Characteristic of Field-Aged 500KV Composite Insulators
    Zhou, You
    Wang, Fochi
    Li, Chengrong
    Jiang, Huai
    Cui, Hang
    2011 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 2011, : 377 - 380
  • [5] Electric Field Distribution Calculation and Analysis of Composite Insulators Operating on Double Circuit Transposition Tower in 500kV Transmission Lines
    Guo, Chenjun
    Liu, Lishuai
    Yu, Hong
    Ma, Yi
    Mei, Hongwei
    Wang, Liming
    2019 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE 2019), 2019, : 486 - 489
  • [6] Investigation on Natural Contamination Deposition of Insulators on ±500kV DC Transmission Lines in Different Environments
    Liu, Qin
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 347 - 349
  • [7] Research on DC Ice-melting Technologies for 500kV AC Transmission Lines
    Hao, Weiwei
    Peng, Shurong
    Lu, Jiazheng
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1663 - 1666
  • [8] Lightning performances for AC 500kV transmission lines with quadruple-circuit on single tower
    Chai, Yajing
    Zhou, Wenjun
    Xue, Li
    Liu, Xiaodong
    Su, Hongmei
    2007 COMPATIBILITY IN POWER ELECTRONICS, 2007, : 83 - 88
  • [9] Typical models of compact transmission lines and application prospect in 500KV AC system of China
    Zhang, B
    Cen, WH
    Huang, JY
    POWERCON '98: 1998 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - PROCEEDINGS, VOLS 1 AND 2, 1998, : 218 - 222
  • [10] Parallel Computation the Potential Distribution and Electric Field along the 500kV Line Composite Insulators
    Li Tianwei
    Ruan Jiangjun
    Xiao Yanling
    Wu Tian
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 501 - +