Efficacy and safety of 3D printing coplanar template-assisted iodine-125 seed implantation as palliative treatment for inoperable pancreatic cancer

被引:5
|
作者
Wang, Baohu [1 ]
Qiu, Bin [2 ]
Wu, Linlin [1 ]
Liu, Yu'e [3 ]
Zhang, Jingxian [3 ]
Wang, Ruoyu [4 ]
Zhang, Kaixian [1 ]
Wang, Junjie [2 ]
机构
[1] Tengzhou Cent Peoples Hosp, Dept Oncol, Zaozhuang 277599, Shandong, Peoples R China
[2] Peking Univ Third Hosp, Dept Radiat Oncol, Beijing, Peoples R China
[3] Shanxi Prov Peoples Hosp, Dept Intervent Therapy, Taiyuan, Peoples R China
[4] Dalian Med Univ, Dept Radiat Oncol, Affiliated Hosp, Dalian, Peoples R China
关键词
3D printing; coplanar template; iodine-125; seed implantation; pancreatic cancer; BRACHYTHERAPY; CARCINOMA; CHEMOTHERAPY; THERAPY; PAIN;
D O I
10.5114/jcb.2022.114990
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate clinical efficacy and safety of 3D printing coplanar template-assisted iodine-125 (I-125) seed implantation as a palliative treatment for inoperable pancreatic cancer. Material and methods: Consecutive 28 patients (16 males and 12 females, median age of 64 years) with histologically diagnosed pancreatic cancer who underwent 3D printing coplanar template-assisted I-125 seed implantation between June 2016 and May 2019 were analyzed. Among these 28 patients, 9 (32.1%) and 19 (67.9%) patients were presenting with tumor node metastasis (TNM) stage IIB and stage III cancer, respectively. Seed implantation was conducted for pain palliation intent in 25 patients and recurrent cancer after radiotherapy in 3 patients. Results: No significant differences were found between pre-planned and post-operative dosimetric parameters, involving D-90, D-100, V-90, V-100, V-150, conformity index, external index, and homogeneity index (all p > 0.05). Two months after implantation, pain relief rate was 76% (19/25) for pain patients. Overall tumor response rate (complete response + partial response) was 60.7% (complete response 0 patients, partial response 17 patients, stable disease 8 patients, and progressive disease 3 patients). Median survival was 10.5 months and estimated 1-year survival rate was 26.7%. Only one patient presented with a slightly upper gastro-intestinal hemorrhage, and another patient suffered from incomplete intestinal obstruction soon after implantation, both recovered after conservative medical treatment without a prolonged hospital stay. No major complication was observed. Conclusions: 3D printing coplanar template-assisted I-125 seed implantation appears to be safe and effective palliative treatment for inoperable pancreatic cancer with favorable clinical outcomes.
引用
收藏
页码:140 / 147
页数:8
相关论文
共 50 条
  • [1] Safety and efficacy of CT-guided radioactive iodine-125 seed implantation assisted by a 3D printing template for the treatment of thoracic malignancies
    Zhe Ji
    Yuliang Jiang
    Fuxin Guo
    Ran Peng
    Haitao Sun
    Jinghong Fan
    Fei Xu
    Junjie Wang
    Journal of Cancer Research and Clinical Oncology, 2020, 146 : 229 - 236
  • [2] Safety and efficacy of CT-guided radioactive iodine-125 seed implantation assisted by a 3D printing template for the treatment of thoracic malignancies
    Ji, Zhe
    Jiang, Yuliang
    Guo, Fuxin
    Peng, Ran
    Sun, Haitao
    Fan, Jinghong
    Xu, Fei
    Wang, Junjie
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2020, 146 (01) : 229 - 236
  • [3] The accuracy and dosimetric analysis of 3D-printing non-coplanar template-assisted iodine-125 seed implantation for recurrent chest wall cancer
    Jiang, Weijuan
    Chen, Yi
    Ji, Zhe
    Jiang, Yuliang
    Qiu, Bin
    Sun, Haitao
    Wang, Junjie
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2021, 13 (03) : 273 - 279
  • [4] Accuracy of 3D printing template-assisted CT-guided radioactive iodine-125 seed implantation for peripheral locally recurrent rectal cancer: A retrospective study
    Xuemin Li
    Hao Wang
    Yuliang Jiang
    Zhe Ji
    Haitao Sun
    Jinghong Fan
    Weiyan Li
    Junjie Wang
    Malignancy Spectrum, 2024, 1 (04) : 323 - 331
  • [5] The accuracy and safety of CT-guided iodine-125 seed implantation assisted by 3D non-coplanar template for retroperitoneal recurrent carcinoma
    Weijuan Jiang
    Ping Jiang
    Shuhua Wei
    Yuliang Jiang
    Zhe Ji
    Haitao Sun
    Jinghong Fan
    Weiyan Li
    Yuxia Shao
    Junjie Wang
    World Journal of Surgical Oncology, 18
  • [6] Preliminary application of 3D-printed coplanar template for iodine-125 seed implantation therapy in patients with advanced pancreatic cancer
    Huang, Wei
    Lu, Jian
    Chen, Ke-Min
    Wu, Zhi-Yuan
    Wang, Qing-Bin
    Liu, Jing-Jing
    Gong, Ju
    Chen, Zhi-Jin
    Ding, Xiao-Yi
    Wang, Zhong-Min
    WORLD JOURNAL OF GASTROENTEROLOGY, 2018, 24 (46) : 5280 - 5287
  • [7] The accuracy and safety of CT-guided iodine-125 seed implantation assisted by 3D non-coplanar template for retroperitoneal recurrent carcinoma
    Jiang, Weijuan
    Jiang, Ping
    Wei, Shuhua
    Jiang, Yuliang
    Ji, Zhe
    Sun, Haitao
    Fan, Jinghong
    Li, Weiyan
    Shao, Yuxia
    Wang, Junjie
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2020, 18 (01)
  • [8] Preliminary application of 3D-printed coplanar template for iodine-125 seed implantation therapy in patients with advanced pancreatic cancer
    Wei Huang
    Jian Lu
    Ke-Min Chen
    Zhi-Yuan Wu
    Qing-Bin Wang
    Jing-Jing Liu
    Ju Gong
    Zhi-Jin Chen
    Xiao-Yi Ding
    Zhong-Min Wang
    World Journal of Gastroenterology, 2018, 24 (46) : 5280 - 5287
  • [9] A review of the efficacy and safety of iodine-125 seed implantation for lung cancer treatment
    Li, Zhouzhou
    Hu, Zhigang
    Xiong, Xiaoqi
    Song, Xinyu
    CANCER TREATMENT AND RESEARCH COMMUNICATIONS, 2024, 41
  • [10] A review on the efficacy and safety of iodine-125 seed implantation in unresectable pancreatic cancers
    Jia, Sheng-Nan
    Wen, Fu-Xing
    Gong, Ting-Ting
    Li, Xin
    Wang, Hui-Jie
    Sun, Ya-Min
    Yang, Ze-Cheng
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2020, 96 (03) : 383 - 389