Screening parameters of pulmonary and cardiovascular integrated model with sensitivity analysis

被引:0
|
作者
Harada, Tatsuya [1 ]
Kubo, Hajime [1 ]
Mori, Taketoshi [1 ]
Sato, Tomomasa [1 ]
机构
[1] Univ Tokyo, Bunkyo Ku, Grad Sch Informat Sci & Technol, 7-3-1 Hongo, Tokyo 113, Japan
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Previously, we built a pulmonary and cardiovascular integrated model which is driven by 02 consumption. However this model is adjusted to average person and cannot correspond to individual difference. It needs parameter adjustment to be applied for simulation of a particular person. We used lumped parameter models, which have simple structures and are well suited to macro-model. However they have a drawback that the number of parameters becomes large if the model describes organs in detail. Since our model has more than 100 parameters, it is ineffective to estimate all parameters. For efficient parameter tuning, we selected important parameters which have significant influence on outputs with a kind of sensitivity analysis method. The model can be well approximated only by the important parameters.
引用
收藏
页码:4152 / +
页数:2
相关论文
共 50 条
  • [1] An efficient integrated approach for global sensitivity analysis of hydrological model parameters
    Zhan, Che-sheng
    Song, Xiao-meng
    Xia, Jun
    Tong, Charles
    ENVIRONMENTAL MODELLING & SOFTWARE, 2013, 41 : 39 - 52
  • [2] Local sensitivity analysis of cardiovascular system parameters
    Gul, R.
    Bernhard, S.
    MODELLING IN MEDICINE AND BIOLOGY X, 2013, 17 : 155 - 167
  • [3] Pulmonary and cardiovascular integrated model controlled with oxygen consumption
    Harada, Tatsuya
    Kubo, Hajime
    Mori, Taketoshi
    Sato, Tomornasa
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 304 - 307
  • [4] Sensitivity analysis of a model of the cardiovascular system
    Kappel, Franz
    Batzel, Jerry
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 6314 - +
  • [5] Sensitivity of the FAA integrated noise model to input parameters
    Clemente, J
    Gaja, E
    Clemente, G
    Reig, A
    APPLIED ACOUSTICS, 2005, 66 (03) : 263 - 276
  • [6] Sensitivity analysis of the photovoltaic model parameters
    Elshatter, TF
    Elhagry, MT
    42ND MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, PROCEEDINGS, VOLS 1 AND 2, 1999, : 914 - 917
  • [7] A Sensitivity Based Approach to Determine the Parameters Variation of a Cardiovascular Model
    Dan, A. M.
    Dragomir, T. L.
    2015 IEEE 10TH JUBILEE INTERNATIONAL SYMPOSIUM ON APPLIED COMPUTATIONAL INTELLIGENCE AND INFORMATICS (SACI), 2015, : 301 - 306
  • [8] SENSITIVITY AND SPECIFICITY OF HEMOSTATIC PARAMETERS IN THE DIAGNOSIS OF PULMONARY ARTERIAL THROMBOEMBOLISM IN CARDIOVASCULAR PATIENTS
    BELOUSOV, YB
    KUDAEV, MT
    RABOTNIKOVA, TV
    KARDIOLOGIYA, 1986, 26 (09) : 63 - 66
  • [9] Sensitivity Analysis and Parameter Estimation of Cardiovascular Model
    Jain, Karan
    Maka, Srinivasu
    2016 INTERNATIONAL CONFERENCE ON SYSTEMS IN MEDICINE AND BIOLOGY (ICSMB), 2016, : 9 - 12
  • [10] Sensitivity Analysis of an Integrated Urban Flood Model
    Nielsen, Rasmus
    Thorndahl, Soren
    NEW TRENDS IN URBAN DRAINAGE MODELLING, UDM 2018, 2019, : 723 - 728