Improved sensitivity X-ray detectors for field applications

被引:8
|
作者
Redus, R [1 ]
Pantazis, J [1 ]
Huber, A [1 ]
Pantazis, T [1 ]
机构
[1] Amptek Inc, Bedford, MA 01730 USA
关键词
gamma-ray detectors; semiconductor radiation detectors; X-ray detectors; X-ray spectroscopy;
D O I
10.1109/TNS.2002.805526
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Thermoelectrically cooled X-ray detectors based on Si-PIN and Cd1-infinity Zn-infinity Te (CZT) devices are now widely used in field-portable X-ray fluorescence (XRF) instrumentation. A previous generation of detectors provided high-energy resolution comparable to that of cryogenic detectors, but at much reduced sensitivity. Recent research at Amptek, Inc., Bedford, MA, has explored several approaches to improving the sensitivity of the detectors for higher energy X-rays. First, larger volume Si-PIN detectors have been integrated with two-stage coolers and Amptek's low-noise electronics. Second, CdTe M-pi-n detectors have been successfully integrated with the thermoelectric cooler hybrid. These devices have many practical advantages for X-ray spectroscopy. Third, a "dual" detector has been developed, consisting of an Si-PIN for high resolution at the lowest energies stacked on a high-Z semiconductor detector for higher sensitivity at the higher energies. The design and performance of sensors utilizing these three approaches will be presented and the results compared with theoretical expectations. All of these detectors are now commercially available and used in commercial products.
引用
收藏
页码:3247 / 3253
页数:7
相关论文
共 50 条
  • [1] Improved sensitivity X-ray detectors for field applications
    Redus, R
    Pantazis, J
    Huber, A
    Pantazis, T
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 986 - 990
  • [2] Improved X-ray silicon detectors for medical applications
    Halmagean, E
    Tsoi, E
    Misiakos, K
    Ohanisian, M
    Veron, A
    Cimpoca, V
    Lazarovici, D
    CAS '96 PROCEEDINGS - 1996 INTERNATIONAL SEMICONDUCTOR CONFERENCE, 19TH EDITION, VOLS 1 AND 2, 1996, : 653 - 656
  • [3] IMPROVED DETECTORS FOR X-RAY ANALYSIS
    DOWLING, PH
    HENDEE, CF
    KOHLER, TR
    PARRISH, W
    ACTA CRYSTALLOGRAPHICA, 1954, 7 (10): : 626 - 626
  • [4] APPLICATIONS OF X-RAY AREA DETECTORS
    ARNDT, UW
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C405 - C405
  • [5] X-ray detectors for NDE applications
    Kroening, Michael
    Melkadze, Revaz G.
    Lezhneva, Tatiana M.
    Khvedelidze, Levan B.
    Kalandadze, Givi D.
    Baumbach, Tilo
    Berthold, Axel
    SENSOR SYSTEMS AND NETWORKS: PHENOMENA, TECHNOLOGY, AND APPLICATIONS FOR NDE AND HEALTH MONITORING 2007, 2007, 6530
  • [6] Determination of X-ray detection limit and applications in perovskite X-ray detectors
    Lei Pan
    Shreetu Shrestha
    Neil Taylor
    Wanyi Nie
    Lei R. Cao
    Nature Communications, 12
  • [7] Determination of X-ray detection limit and applications in perovskite X-ray detectors
    Pan, Lei
    Shrestha, Shreetu
    Taylor, Neil
    Nie, Wanyi
    Cao, Lei R.
    NATURE COMMUNICATIONS, 2021, 12 (01)
  • [8] Dependence of x-ray sensitivity of direct conversion x-ray detectors on x-ray exposure and exposure history
    Kabir, MZ
    Yunus, M
    Kasap, SO
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 170 - 176
  • [9] IQI sensitivity and applications of flat panel detectors and X-ray image intensifiers - a comparison
    Purschke, M
    MATERIALPRUFUNG, 2003, 45 (1-2): : 29 - 33
  • [10] IMPROVED ENERGY RESOLUTION WITH X-RAY GAS DETECTORS
    POLICARPO, AJ
    ALVES, MAF
    CARVALHO, MJ
    DAROCHA, MAG
    NUCLEAR INSTRUMENTS & METHODS, 1971, 96 (03): : 487 - +