Diagnostic value of D-dimer in patients with suspected pulmonary embolism:: Results from a multicentre outcome study

被引:30
|
作者
Parent, Florence
Maitre, Sophie
Meyer, Guy
Raherison, Chantal
Mal, Herve
Lancar, Remi
Couturaud, Francis
Mottier, Dominique
Girard, Philippe
Simonneau, Gerald
Leroyer, Christophe [1 ]
机构
[1] Hop Antoine Beclere, Assistance Publ Hop Paris, Clamart, France
[2] Inst Mutual Montsouris, Paris, France
[3] Univ Paris 05, Hop Europeen Georges Pompidou, Fac Med, Assitance Publ Hop Paris, Paris, France
[4] Hop Haut Leveque, Bordeaux, France
[5] Hop Univ Beaujon, Clichy, France
[6] INSERM, EMI 0214, Paris, France
[7] Hop Cavale Blanche, EA 3878, Brest, France
关键词
pulmonary embolism; pre-test clinical; probability; plasma D-dimers; sensitivity; negative predictive value; number needed to test;
D O I
10.1016/j.thromres.2006.09.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: D-dimer tests are used in various diagnostic strategies to exclude pulmonary embolism (PE). However, their rote as an exclusionary first-line test is still uncertain, mainly because accuracy of the test varies according to the assay and the studied population. Methods: The aim of this multicentre study was to evaluate the accuracy of D-dimer testing in patients with suspected PE. Diagnosis of PE was based on pre-test clinical probability (PCP) evaluation and both single-detector spiral CT (CT) and lower limbs compression ultrasonography (CUS). Lung scanning and/or pulmonary angiography was mandatory when CT or CUS was inconclusive and when both CT and CUS were normal in a patient with a high PCR All patients were followed-up for 3 months, looking for VTE recurrence. D-dimers were collected within 24 h of inclusion and stored in each local hematology unit, to be analyzed at the end of all inclusions; physicians in charge of the patient were blinded to D-dimer results. Results: Three hundred and fifty two patients were included in 4 centres. Prevalence of PE was 38.6%. PCP was low in 82 (23.3%), intermediate in 176 (50%) and high in 94 (26.7%) patients. Sensitivity of D-dimer was 96.3% (95% CI: 93-99) and negative predictive value reached 94.4% (95% CI: 90-99). Five patients with a confirmed PE had a D-dimer level below 500 ng/ml (two patients with a high PCP). Among 258 patients with low or intermediate PCP, 80 (31%) had a negative D-dimer test result; three of them had a false negative result and the number needed to test was 3.3. Among 94 patients with a high PCP, 9 had a negative D-dimer test result; two of them had a false negative result and the number needed to test was 13.5. Conclusion: These results confirm that rapid assays used in this study can safety exclude PE in first-line testing only in non-high CP patients. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [1] Diagnostic accuracy of D-dimer assay in suspected pulmonary embolism patients
    Youssf, Abdel Rahem I.
    Ismail, Mohammed F. M.
    ElGhamry, Reda
    Reyad, Mahmoud R.
    EGYPTIAN JOURNAL OF CHEST DISEASES AND TUBERCULOSIS, 2014, 63 (02): : 411 - 417
  • [2] DIAGNOSTIC-VALUE OF PLASMA D-DIMER IN SUSPECTED PULMONARY-EMBOLISM
    BOUNAMEAUX, H
    SLOSMAN, D
    DEMOERLOOSE, P
    REBER, G
    LANCET, 1988, 2 (8611): : 628 - 629
  • [3] D-dimer in the diagnostic workup of suspected pulmonary embolism - Additional clinical value of pretest probability
    Cacciola, RR
    Cacciola, E
    Polosa, R
    CHEST, 2005, 127 (04) : 1467 - 1468
  • [4] Diagnostic value of d-dimer in the diagnosis of pulmonary embolism in pregnancy
    Sadeghi, Somayeh
    Safaian, Bahareh
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [5] D-dimer testing for suspected pulmonary embolism
    Perrier, A
    Desmarais, S
    Goehring, C
    deMoerloose, P
    Morabia, A
    Unger, PF
    Slosman, D
    Junod, A
    Boundameaux, H
    THROMBOSIS AND HAEMOSTASIS, 1997, : PD646 - PD646
  • [6] D-dimer tests for assessment of patients with suspected pulmonary embolism
    Caine, GJ
    Lip, GYH
    ARCHIVES OF INTERNAL MEDICINE, 2003, 163 (02) : 243 - 243
  • [7] D-DIMER IN PATIENTS WITH CLINICALLY SUSPECTED PULMONARY-EMBOLISM
    GINSBERG, JS
    BRILLEDWARDS, PA
    DEMERS, C
    DONOVAN, D
    PANJU, A
    CHEST, 1993, 104 (06) : 1679 - 1684
  • [8] Prognostic value of D-dimer in patients with pulmonary embolism
    Aujesky, Drahomir
    Roy, Pierre-Marie
    Guy, Meyer
    Cornuz, Jacques
    Sanchez, Olivier
    Perrier, Arnaud
    THROMBOSIS AND HAEMOSTASIS, 2006, 96 (04) : 478 - 482
  • [9] Pulmonary embolism in patients with COVID-19 and D-dimer diagnostic value: A retrospective study
    Vivan, Manoela Astolfi
    Rigatti, Brenda
    da Cunha, Sainan Voss
    Frison, Guilherme Cristianetti
    Antoniazzi, Lucas Quadros
    de Oliveira, Paulo Henrique Kranz
    Oliveira, Joao Pedro Souza
    Fontanari, Clara
    Seligman, Beatriz Graeff Santos
    Seligman, Renato
    BRAZILIAN JOURNAL OF INFECTIOUS DISEASES, 2022, 26 (06):
  • [10] The value of the SimpliRed(R) D-dimer in a prospective management study of patients with suspected pulmonary embolism (PE).
    Wells, P
    Ginsberg, J
    Anderson, D
    Hirsh, J
    Turpie, A
    Bormanis, J
    Kearon, C
    Weitz, J
    BLOOD, 1996, 88 (10) : 137 - 137