Plastic scintillator-based fibre dosimeters for measurement of X-ray pulses in a clinical setting

被引:2
|
作者
Kam, W. [1 ,2 ]
Ioannou, A. [3 ]
Martyn, M. [4 ]
Sullivan, F. J. [4 ,5 ]
Pospori, A. [3 ]
Woulfe, P. [4 ]
Kalli, K. [3 ]
O'Keeffe, S. [1 ,2 ]
机构
[1] Univ Limerick, Opt Fibre Sensors Res Ctr OFSRC, Limerick V94 T9PX, Ireland
[2] Univ Limerick, Hlth Res Inst, Limerick V94 T9PX, Ireland
[3] Cyprus Univ Technol, Photon & Opt Sensors Res Lab PhOSLab, Saripolou 33, CY-3036 Limassol, Cyprus
[4] Galway Clin, Dept Radiotherapy, Galway, Ireland
[5] Galway Clin, Prostate Canc Inst, Galway, Ireland
基金
爱尔兰科学基金会; 欧盟地平线“2020”;
关键词
Optical fibres; BCF-10; X-ray; Radiation Sensor; Femtosecond laser micro-machining;
D O I
10.1117/12.2624516
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work presents the development of plastic scintillator (BCF-10) based optical fibre sensors for medical radiotherapy dosimetry. Two different designs of BCF10 joined to PMMA (Polymethyl methacrylate) fibre were considered, based on simple Plug and Play designs for the rapid and effective assembly of radiation sensors. The first design was a simple buttcoupling arrangement sheathed in tubing, with an outer diameter of < 2 mm. The second design explored the coupling joint of a cylindrical protrusion and hollow part of BCF10-PMMA that were achieved using femtosecond laser machining; the purpose of which was to maintain the original 1-mm fibre diameter for the sensor probe. The two fibres were pressed together and sealed with UV curing, hence the reference to a Plug and Play architecture. Both sensors exhibit higher output counts at the higher dose rate (due to the higher number of radiation pulses), although a discernible signal is observed at 50 MU/min for 6 MV, 15 MV energies and both sensors. When comparing both sensors with the different joint coupling designs, the flat surface connection of BCF-10 to PMMA demonstrates slightly higher photon counts compared with the micro- machined sensor (Plug n Play). However, the difference is small and the Plug n Play sensor benefits from the smaller sensor diameter (1 mm diameter), which is suitable for inserting into a small applicator or in-vivo monitoring. In the second section, micro-pulses of X- Ray radiation from Siemens Linear Accelerator (linac) were obtained and compared for two different energies and dose rates. Both of the sensors demonstrate the feasibility to be used for characterisation of X-ray pulses from a clinical linac.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Plastic scintillator-based dosimeters for FLASH radiotherapy
    Ciarrocchi, E.
    Morrocchi, M.
    Del Sarto, D.
    Di Martino, F.
    Linsalata, S.
    Pensavalle, J. H.
    Bisogni, M. G.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S779 - S780
  • [2] A scintillator-based hard X-ray imaging telescope - CASTER
    Cherry, M. L.
    Blose, P. F.
    Case, G. L.
    Cravens, J. P.
    Guzik, T. G.
    Hurley, K. C.
    Isbert, J. B.
    Kippen, R. M.
    Macri, J. M.
    McConnell, M. L.
    Miller, R. S.
    Paciesas, W. S.
    Ryan, J. M.
    Schaefer, B. E.
    Stacy, J. G.
    Vestrand, W. T.
    Wefel, J. P.
    Welch, C. E.
    Proceedings of the 29th International Cosmic Ray Conference, Vol 5: OG 2.5, 2.6 & 2.7, 2005, : 407 - 410
  • [3] 3-D modeling of scintillator-based X-ray detectors
    Vieira da Rocha, Jose Gerardo
    Lanceros-Mendez, Senentxu
    IEEE SENSORS JOURNAL, 2006, 6 (05) : 1236 - 1242
  • [4] Scintillator-based flat-panel x-ray imaging detectors
    Granfors, Paul R.
    Albagli, Douglas
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2009, 17 (06) : 535 - 542
  • [5] Scintillator-based diagnostics for x-ray measurements of ion-driven Hohlraums
    Barber, T.L.
    Derzon, M.S.
    IEEE International Conference on Plasma Science,
  • [6] X-ray Nanocrystal Scintillator-Based Aptasensor for Autofluorescence-Free Detection
    Ou, Xiangyu
    Chen, Yanyan
    Xie, Lili
    Chen, Jie
    Zan, Jie
    Chen, Xiaofeng
    Hong, Zhongzhu
    He, Yu
    Li, Juan
    Yang, Huanghao
    ANALYTICAL CHEMISTRY, 2019, 91 (15) : 10149 - 10155
  • [7] Plastic scintillator-based dosimeters for ultra-high dose rate (UHDR) electron radiotherapy
    Ciarrocchi, E.
    Ravera, E.
    Cavalieri, A.
    Celentano, M.
    Del Sarto, D.
    Di Martino, F.
    Linsalata, S.
    Massa, M.
    Masturzo, L.
    Moggi, A.
    Morrocchi, M.
    Pensavalle, J. H.
    Bisogni, M. G.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 121
  • [8] Ultrafast inorganic scintillator-based front imager for Gigahertz Hard X-ray imaging
    Hu, Chen
    Zhang, Liyuan
    Zhu, Ren-Yuan
    Demarteau, Marcel
    Wagner, Robert
    Xia, Lei
    Xie, Junqi
    Li, Xuan
    Wang, Zhehui
    Shih, Yanhua
    Smith, Thomas
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 940 : 223 - 229
  • [9] Ultra-Broad Emission Copper Halide Scintillator-Based X-Ray Imager
    Lv, Haocheng
    Shao, Wenyi
    Chen, Haifeng
    Zhu, Guoyang
    Wang, Yao
    Zhang, Zhenzhong
    Liang, Hongwei
    ADVANCED SCIENCE, 2025, 12 (04)
  • [10] The influence of electron multiplication and internal X-ray fluorescence on the performance of a scintillator-based gamma camera
    Hall, David J.
    Holland, Andrew
    Soman, Matthew
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 678 : 64 - 77