Smart water supply system: a quasi intelligent diagnostic method for a distribution network

被引:1
|
作者
Kowalski, Dariusz [1 ]
Kowalska, Beata [1 ]
Suchorab, Pawel [1 ]
机构
[1] Lublin Univ Technol, Fac Environm Engn, Dept Water Supply & Wastewater Disposal, Lublin, Poland
关键词
Water network; Diagnostic method; Water losses; Leakages;
D O I
10.1007/s13201-022-01656-w
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Constantly developing monitoring systems provide a large amount of raw data. In many cases, the operators of water supply systems (WSS) have already reached their perception limit for analysing information. Therefore, the managing process of the WSS requires quasi-intelligent informatics systems, the main purpose of which is to minimise the WSS operating costs in addition to maintaining the proper water delivery to customers. It can be achieved by the detection of abnormal functioning of WSS operations (leakages, water outages). The standard SCADA monitoring systems, in most cases, are not able to distinguish a significant water leakage and water tank filling process. Such cases occur relatively often in complex water supply systems with many water tanks. The aim of this paper is to present the quasi intelligent method of detecting abnormal WSS functioning, including its concepts and effects after a 3 month period operation. The essence of the detection method is the integration of numerical model (built-in Bentley WaterGEMS software) and SCADA monitoring system. The monitoring data are constantly compared to the simulation results and when accepted accordance limits are exceeded, the appropriate alerts are generated. Such solution cause the WSS operator does not need to analyse SCADA system indications constantly. The additional application of the method enables the detection of essential water leakages.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Smart water supply system: a quasi intelligent diagnostic method for a distribution network
    Dariusz Kowalski
    Beata Kowalska
    Paweł Suchorab
    Applied Water Science, 2022, 12
  • [2] THE DEVELOPMENT OF AN INTELLIGENT MONITORING SYSTEM OF A LOCAL WATER SUPPLY NETWORK
    Wyczolkowski, Ryszard
    Matysiak, Grzegorz
    EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY, 2009, (02): : 71 - 75
  • [3] The development of an intelligent monitoring system of a local water supply network
    WyczóLkowski, Ryszard
    Matysiak, Grzegorz
    Eksploatacja i Niezawodnosc, 2009, 42 (02) : 71 - 75
  • [4] Method of flow distribution in design of water supply network
    Yu, Guoping
    2000, Zhongguo Shizheng Gongcheng Huabei Shijiyuan, China (16):
  • [5] Method of flow distribution in design of water supply network
    Yu, Guoping
    Zhongguo Jishui Paishui/China Water & Wastewater, 2000, 16 (04): : 31 - 33
  • [6] The Concept of Intelligent Chlorine Dosing System in Water Supply Distribution Networks
    Wyczolkowski, Ryszard
    Piechowski, Mariusz
    Gladysiak, Violetta
    Jasiulewicz-Kaczmarek, Malgorzata
    INTELLIGENT SYSTEMS IN PRODUCTION ENGINEERING AND MAINTENANCE, 2019, 835 : 350 - 359
  • [7] Showcasing a smart water network based on an experimental water distribution system
    Guenther, M.
    Camhy, D.
    Steffelbauer, D.
    Neumayer, M.
    Fuchs-Hanusch, D.
    COMPUTING AND CONTROL FOR THE WATER INDUSTRY (CCWI2015): SHARING THE BEST PRACTICE IN WATER MANAGEMENT, 2015, 119 : 450 - 457
  • [8] Intelligent management system of water supply in cities based on neural network
    Zeng, Guang
    Liang, Huibing
    Jisuanji Gongcheng/Computer Engineering, 2000, 26 (09): : 143 - 145
  • [9] Virtual reality simulation system for water supply and distribution network
    Wu, Wenyan
    Gao, Jinliang
    Chang, Kui
    INTERNATIONAL JOURNAL OF COMPUTER APPLICATIONS IN TECHNOLOGY, 2012, 45 (04) : 205 - 213
  • [10] Future Distribution Generation in an Intelligent Smart Energy Network
    Matheri, A. N.
    Belaid, M.
    van Rensburg, N. Janse
    Mahlatsi, Thabo
    2019 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT (IEEM), 2019, : 298 - 303