Measurement of labile Cu in soil using stable isotope dilution and isotope ratio analysis by ICP-MS

被引:44
|
作者
Nolan, AL
Ma, YB
Lombi, E
McLaughlin, MJ
机构
[1] CSIRO Land & Water, Ctr Environm Contaminants Res, Glen Osmond, SA 5064, Australia
[2] Chinese Acad Agr Sci, Inst Soil & Fertilizers, Beijing, Peoples R China
[3] Univ Adelaide, Sch Earth & Environm Sci, Glen Osmond, SA 5064, Australia
关键词
soil; copper; labile pool; isotope dilution; isotope ratios; ICP-MS;
D O I
10.1007/s00216-004-2816-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Isotope dilution is a useful technique to measure the labile metal pool, which is the amount of metal in soil in rapid equilibrium (< 7 days) with the soil solution. This is normally performed by equilibrating soil with a metal isotope, and sampling the labile metal pool by using an extraction ( E value), or by growing plants ( L value). For Cu, this procedure is problematic for E values, and impossible for L values, due to the short half-life of the Cu-64 radioisotope (12.4 h), which makes access and handling very difficult. We therefore developed a technique using enriched Cu-65 stable isotope and measurement of Cu-63/Cu-65 ratios by quadrupole inductively coupled plasma mass spectrometry (ICP-MS) to measure labile pools of Cu in soils using E value techniques. Mass spectral interferences in detection of Cu-63/Cu-65 ratios in soil extracts were found to be minimal. Isotope ratios determined by quadrupole ICP-MS compared well to those determined by high-resolution ( magnetic sector) ICP-MS. E values determined using the stable isotope technique compared well to those determined using the radioisotope for both uncontaminated and Cu-contaminated soils.
引用
收藏
页码:789 / 797
页数:9
相关论文
共 50 条
  • [1] Measurement of labile Cu in soil using stable isotope dilution and isotope ratio analysis by ICP-MS
    Annette L. Nolan
    Yibing Ma
    Enzo Lombi
    Mike J. McLaughlin
    Analytical and Bioanalytical Chemistry, 2004, 380 : 789 - 797
  • [2] Isotope dilution ICP-MS for speciation studies
    Clough, R
    Truscatt, J
    Belt, ST
    Evans, EH
    Fairman, B
    Catterick, T
    APPLIED SPECTROSCOPY REVIEWS, 2003, 38 (01) : 101 - 132
  • [3] Multicollector ICP-MS for isotope ratio analysis of uranium
    Hart, Garret
    Pratt, Sandra
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [4] Measurement of calcium stable isotope tracers using cool plasma ICP-MS
    Patterson, KY
    Veillon, C
    Hill, AD
    Moser-Veillon, PB
    O'Haver, TC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (11) : 1673 - 1677
  • [5] Multi-element isotope dilution analyses using ICP-MS
    Volpe, A.M.
    Atomic Energy of Canada Limited, AECL (Report), 1996, (11342):
  • [6] Analysis of cadmium and lead in sediment by isotope-dilution ICP-MS
    Inagaki, K
    Takatsu, A
    Nakama, A
    Uchiumi, A
    Okamoto, K
    BUNSEKI KAGAKU, 2001, 50 (12) : 829 - 835
  • [7] Lead isotope ratio analysis of bullet samples by using quadrupole ICP-MS
    Tamura, Shu-ichi
    Hokura, Akiko
    Oishi, Masahiro
    Nakai, Izumi
    BUNSEKI KAGAKU, 2006, 55 (11) : 827 - 834
  • [8] Determination of molybdenum and enriched Mo stable isotope concentrations in human blood plasma by isotope dilution ICP-MS
    Keyes, WR
    Turnlund, JR
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) : 1153 - 1156
  • [9] Measurement of mercury isotope ratios using multicollector ICP-MS
    Hintelmann, H
    Foucher, D
    Evans, RD
    Dillon, P
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2003, 67 (18) : A147 - A147
  • [10] DETERMINATION OF STABLE ISOTOPE RATIO OF LEAD IN AIRBORNE PARTICULATE MATTER BY ICP-MS
    MUKAI, H
    AMBE, Y
    BUNSEKI KAGAKU, 1990, 39 (03) : 177 - 182