Critical implementation issues of excitation signals for embedded wearable bioimpedance spectroscopy systems with limited resources

被引:24
|
作者
Kallel, A. Y. [1 ]
Bouchaala, D. [2 ]
Kanoun, O. [1 ]
机构
[1] Tech Univ Chemnitz, Chair Measurement & Sensor Technol, Chemnitz, Germany
[2] Natl Engn Sch Sfax, Digital Res Ctr Sfax, Sfax, Tunisia
关键词
bioimpedance spectroscopy; excitation signal; spectral energy efficiency; crest factor; embedded systems; real implementation; timer; FACTOR MINIMIZATION; TIME;
D O I
10.1088/1361-6501/abf78e
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Wideband excitation signals are essential in bioimpedance spectroscopy for measurements in a time ensuring a quasi-stable measurement condition. In particular, for wearable biomedical systems, due to limited system resources, several aspects regarding measurement time, crest factor, slew rate requirements, frequency distribution, amplitude spectrum, and energy efficiency need to be thoroughly investigated. In this paper, we present an investigation of excitation signals, which includes not only the theoretical aspects but also aspects of real implementation on microcontroller-based systems. At a fixed number of samples and sampling rate, we investigate the implementability of signal frequencies and the resulting spectral efficiency. We focus on sources of signal distortion due to timer and amplitude deviations. The results show that for 4096 samples and a sampling frequency of 1 MHz, wideband signals are 2.76 times faster than a stepped frequency sweep. The multisine signal provides a better energy efficiency and has a lower slew rate requirement on hardware (around 0.3 V mu s(-1)), but has a relatively high crest factor, even after optimization. An exemplary investigation of the distortion of the time/frequency and amplitudes following implementation on a standard industrial advanced RISC machines microcontroller has shown that a sampling rate compensation is required to overcome timer inaccuracies. Furthermore, non-return-to-zero binary signals are more sensitive to distortion due to hardware-related issues and have a lower signal-to-distortion-and-noise (SINAD) ratio than 24 dB, which is lower than the multisine signal, having a SINAD of 31 dB.
引用
收藏
页数:14
相关论文
共 17 条
  • [1] Design of tri-level excitation signals for broadband bioimpedance spectroscopy
    Yang, Yuxiang
    Wang, Lianhuan
    Wang, Peipei
    Yang, Xiufang
    Zhang, Fu
    Wen, He
    Teng, Zhaosheng
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (09) : 1995 - 2007
  • [2] Comparative Study of Measurement Methods for Embedded Bioimpedance Spectroscopy Systems
    Ben Atitallah, Bilel
    Kallel, Ahmed Yahia
    Bouchaala, Dhouha
    Derbel, Nabil
    Kanoun, Olfa
    SENSORS, 2022, 22 (15)
  • [3] Hardware implementation of language resources for embedded systems
    Rojc, M
    Kacic, Z
    Kramberger, L
    INFORMACIJE MIDEM-JOURNAL OF MICROELECTRONICS ELECTRONIC COMPONENTS AND MATERIALS, 2002, 32 (03): : 199 - 203
  • [4] Development of coroutines usage model for cooperative multitasking implementation on the systems with limited resources
    Mohammed, Amin Salih
    Filippenko, Inna
    Balaji, B. Saravana
    Barkovska, Olesia
    Semenenko, Ivan
    Korniienko, Valentyn
    ANNALS OF OPERATIONS RESEARCH, 2023, 326 (SUPPL 1) : 107 - 107
  • [5] Development, implementation, and experimental outdoor evaluation of quadcopter controllers for computationally limited embedded systems
    Paredes, Juan
    Sharma, Prashin
    Ha, Brian
    Lanchares, Manuel
    Atkins, Ella
    Gaskell, Peter
    Kolmanovsky, Ilya
    ANNUAL REVIEWS IN CONTROL, 2021, 52 (52) : 372 - 389
  • [6] Design and Implementation of an Escape Analysis in the Context of Safety-Critical Embedded Systems
    Lang, Clemens
    Stilkerich, Isabella
    ACM TRANSACTIONS ON EMBEDDED COMPUTING SYSTEMS, 2020, 19 (01)
  • [7] RETRACTED ARTICLE: Development of coroutines usage model for cooperative multitasking implementation on the systems with limited resources
    Amin Salih Mohammed
    Inna Filippenko
    B. Saravana Balaji
    Olesia Barkovska
    Ivan Semenenko
    Valentyn Korniienko
    Annals of Operations Research, 2023, 326 : 107 - 107
  • [8] Comparative Study of AC Signal Analysis Methods for Impedance Spectroscopy Implementation in Embedded Systems
    Kallel, Ahmed Yahia
    Hu, Zheng
    Kanoun, Olfa
    APPLIED SCIENCES-BASEL, 2022, 12 (02):
  • [9] Detection of Electrocardiographic and Respiratory Signals from Transthoracic Bioimpedance Spectroscopy Measurements with a Wearable Monitor for Improved Home-Based Disease Management in Congestive Heart Failure
    Dovancescu, Silviu
    Para, Attila
    Riistama, Jamo
    2014 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 41, 2014, 41 : 985 - 988
  • [10] A Low-Cost Implementation of Sample Entropy in Wearable Embedded Systems: An Example of Online Analysis for Sleep EEG
    Wang, Yung-Hung
    Chen, I-Yu
    Chiueh, Herming
    Liang, Sheng-Fu
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70