Detection of glycosaminoglycans as a copper(II) complex in high-performance liquid chromatography

被引:20
|
作者
Toida, T
Shima, M
Azumaya, S
Maruyama, T
Toyoda, H
Imanari, T
Linhardt, RJ
机构
[1] CHIBA UNIV,FAC PHARMACEUT SCI,INAGE KU,CHIBA 263,JAPAN
[2] UNIV IOWA,PHAR S328,DIV MED & NAT PROD CHEM,IOWA CITY,IA 52242
[3] UNIV IOWA,PHAR S328,DEPT CHEM & BIOCHEM ENGN,IOWA CITY,IA 52242
关键词
detection; LC; derivatization; glycosaminoglycans; glycans; metal complexes; copper complexes;
D O I
10.1016/S0021-9673(97)00658-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Glycosaminoglycans including heparin, heparan sulfate, chondroitin sulfate, dermatan sulfate and hyaluronan were analyzed by high-performance gel filtration chromatography. Detection was achieved at 240 nm based on the formation of copper(II) complex in copper sulfate solution at low pH. Detection of the copper(II)-heparin complex is sensitive, permitting the analysis of as little as 10(-7) g. This method was also successfully applied to the analysis of the chemically derivatized glycosaminoglycans (de-N-acetylated and/or oversulfated chondroitin sulfate) that cannot be depolymerized by enzymes such as heparin and chondroitin lyases. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:266 / 270
页数:5
相关论文
共 50 条
  • [1] ANALYSIS OF GLYCOSAMINOGLYCANS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    TAKAGAKI, K
    TAKEDA, Y
    NAKAMURA, T
    DAIDOUJI, K
    NARITA, H
    ENDO, M
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1994, 28 (04): : 313 - 320
  • [2] FRACTIONATION OF AORTA GLYCOSAMINOGLYCANS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LEE, YJ
    RADHAKRISHNAMURTHY, B
    DALFERES, ER
    BERENSON, GS
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 419 : 275 - 279
  • [3] Analysis of glycosaminoglycans in human prostate by high-performance liquid chromatography
    Iida, S
    Suzuki, K
    Matsuoka, K
    Takazono, I
    Shimada, A
    Inoue, M
    Yahara, J
    Noda, S
    BRITISH JOURNAL OF UROLOGY, 1997, 79 (05): : 763 - 769
  • [4] ANALYSIS OF DENTIN GLYCOSAMINOGLYCANS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HJERPE, A
    ANTONOPOULOS, CA
    ENGFELDT, B
    WIKSTROM, B
    CALCIFIED TISSUE INTERNATIONAL, 1983, 35 (4-5) : 496 - 501
  • [5] Copper electrodes for stable subpicomole detection of carbohydrates in high-performance liquid chromatography
    Kano, K
    Takagi, K
    Inoue, K
    Ikeda, T
    Ueda, T
    JOURNAL OF CHROMATOGRAPHY A, 1996, 721 (01) : 53 - 57
  • [6] High-performance liquid chromatography of amino acids in copper(II) complex form: Application to valine fermentation samples
    Polanuer, BM
    Ivanov, SV
    JOURNAL OF CHROMATOGRAPHY A, 1996, 722 (1-2) : 311 - 315
  • [7] SIMULTANEOUS DETERMINATION OF COPPER(II) AND NICKEL(II) WITH POTASSIUM ETHYL XANTHATE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    NAGAOSA, Y
    DENKI KAGAKU, 1991, 59 (06): : 504 - 507
  • [8] IDENTIFICATION OF GLYCOSAMINOGLYCANS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON A HYDROXYAPATITE COLUMN
    NARITA, H
    TAKEDA, Y
    TAKAGAKI, K
    NAKAMURA, T
    HARATA, S
    ENDO, M
    ANALYTICAL BIOCHEMISTRY, 1995, 232 (01) : 133 - 136
  • [9] A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR THE DETERMINATION OF GLYCOSAMINOGLYCANS IN HUMAN BLOOD
    GASSLER, N
    REISSNER, C
    JANZEN, N
    KAHNERT, H
    KLEESIEK, K
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1993, 31 (08): : 503 - 511
  • [10] ANALYSIS OF UNSATURATED DISACCHARIDES FROM GLYCOSAMINOGLYCANS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    NOMURA, Y
    TADE, H
    TAKAHASHI, K
    WADA, K
    AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1989, 53 (12): : 3313 - 3315