Effects of Concrete Composition on Resistance to Microbially Induced Corrosion

被引:15
|
作者
Ding, Ling [1 ]
Weiss, W. Jason [2 ]
Blatchley, Ernest R., III [3 ]
机构
[1] Purdue Univ, Lyles Sch Civil Engn, 550 Stadium Mall Dr, W Lafayette, IN 47907 USA
[2] Oregon State Univ, Sch Civil & Construct Engn, Kearney Hall,1491 SW Campus Way, Corvallis, OR 97331 USA
[3] Purdue Univ, Lyles Sch Civil Engn, Div Environm & Ecol Engn, 550 Stadium Mall Dr, W Lafayette, IN 47907 USA
关键词
Microbially induced corrosion; Corrosion; Acidothiobacillus spp. bacteria; H2S(g); Sulfuric acid; Concrete; Cement; Calcium aluminate cement; Chamber; Surface pH; SULFATE ATTACK; BACTERIA; CAPACITY;
D O I
10.1061/(ASCE)EE.1943-7870.0001197
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Microbially induced corrosion (MIC) is a process that can take place in concrete sewers, septic tanks, and transfer stations and can result in concrete deterioration. MIC is attributable to the microbial oxidation of hydrogen sulfide (H2S) to sulfuric acid (H2SO4) by a biofilm community that is established on a concrete surface. The rate and extent of this process will be influenced by the environment in which it takes place (e.g., temperature, H2S concentration), as well as the composition of the concrete itself. Laboratory experiments were conducted to examine the effect of concrete composition and admixtures on MIC. The experiments were conducted in an isolated chamber where the climate was controlled, including the H2S concentration. Concrete specimens representing 13 mixtures were inoculated with an aqueous suspension containing a mixture of four Acidothiobacillus spp. that have been associated with MIC in sewer systems. Results indicated that calcium aluminate cement (CAC) mortar, blended cement, and incorporation of a silane quaternary amine (SQA) antimicrobial agent can improve resistance to MIC under moderate exposure conditions (i.e., surface pH > 2.0). The rapid deterioration of specimens exposed to more aggressive conditions in the chamber indicated that degradation of concrete under the most severe MIC conditions (i.e., concrete surface pH < 2.0) was not prevented by simply manipulating concrete mixture proportions. A second set of experiments was conducted to quantify the effectiveness of SQA for the inactivation of pure cultures of planktonic bacteria. Results indicated that the antimicrobial agent performed well for the inactivation of pure cultures of Acidothiobacillus spp., except A. thiooxidans, which represent bacteria that are likely to be active under the most severe conditions (i.e., surface pH < 2). (C) 2017 American Society of Civil Engineers.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Microbially Induced Corrosion of Concrete
    Lines, Samuel J.
    Rothstein, David A.
    Rollins, Brent
    Alt, Charles
    Concrete International, 2021, 43 (05) : 28 - 32
  • [2] Improvement in the microbially induced corrosion resistance of concrete sewers using electrodeposition
    Zhu, Zhengyu
    Chu, Hongqiang
    Jiang, Sheng
    Guo, Ming-Zhi
    Xu, Yi
    Liang, Yunchao
    Jiang, Linhua
    CEMENT & CONCRETE COMPOSITES, 2022, 134
  • [3] Increased Resistance of Nitrite-Admixed Concrete to Microbially Induced Corrosion in Real Sewers
    Li, Xuan
    Bond, Philip L.
    Moore, Liza
    Wilkie, Simeon
    Hanzic, Lucija
    Johnson, Ian
    Mueller, Kara
    Yuan, Zhiguo
    Jiang, Guangming
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2020, 54 (04) : 2323 - 2333
  • [4] Distinct microbially induced concrete corrosion at the tidal region of reinforced concrete sewers
    Song, Yarong
    Tian, Yimei
    Li, Xuan
    Wei, Jing
    Zhang, Haiya
    Bond, Philip L.
    Yuan, Zhiguo
    Jiang, Guangming
    WATER RESEARCH, 2019, 150 : 392 - 402
  • [5] Review on Microbially Influenced Concrete Corrosion
    Wang, Dongsheng
    Guan, Fang
    Feng, Chao
    Mathivanan, Krishnamurthy
    Zhang, Ruiyong
    Sand, Wolfgang
    MICROORGANISMS, 2023, 11 (08)
  • [6] Biomineralization To Prevent Microbially Induced Corrosion on Concrete for Sustainable Marine Infrastructure
    Sun, Xiaohao
    Wai, Onyx W. H.
    Xie, Jiawen
    Li, Xiangdong
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2023, 58 (01) : 522 - 533
  • [7] Qualitative Investigation of Microbially Induced Corrosion of Concrete in Sanitary Sewer Pipe and Manholes
    Kaushal, Vinayak
    Najafi, Mohammad
    Love, Johnny
    PIPELINES 2018: CONDITION ASSESSMENT, CONSTRUCTION, AND REHABILITATION, 2018, : 768 - 775
  • [8] Concrete Resistance to Sulfuric Acid Immersion: The Influence of Testing Details and Mixture Design on Performance as It Relates to Microbially Induced Corrosion
    House, Mitch
    Cheng, Liqiu
    Banks, Kathy
    Weiss, Jason
    ADVANCES IN CIVIL ENGINEERING MATERIALS, 2019, 8 (01): : 544 - 557
  • [9] Effect of Corrosion Inhibitors on Concrete Pore Solution Composition and Corrosion Resistance
    O'Reilly, M.
    Darwin, D.
    Browning, J.
    Xing, L.
    Locke, C. E., Jr.
    Virmani, Y. P.
    ACI MATERIALS JOURNAL, 2013, 110 (05) : 577 - 585
  • [10] Effect of corrosion inhibitors on concrete pore solution composition and corrosion resistance
    University of Kansas, ACI Technical Activities Committee, Lawrence, KS, United States
    不详
    不详
    不详
    ACI Mater J, 2013, 5 (577-585):