Simultaneous detection of Cd(II) and Pb(II) by differential pulse anodic stripping voltammetry at a nitrogen-doped microporous carbon/Nafion/bismuth-film electrode

被引:200
|
作者
Xiao, Lili [1 ,2 ]
Xu, Hongbo [1 ,2 ]
Zhou, Shenghai [1 ]
Song, Ting [1 ,2 ]
Wang, Huanhuan [1 ]
Li, Shouzhu [1 ]
Gan, Wei [1 ]
Yuan, Qunhui [1 ]
机构
[1] Chinese Acad Sci, Xinjiang Tech Inst Phys & Chem, Lab Environm Sci & Technol, Key Lab Funct Mat & Devices Special Environm, Urumqi 830011, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金; 对外科技合作项目(国际科技项目);
关键词
Nitrogen Doped Microporous Carbon (NMC); Differential Pulse Anodic Stripping; Voltammetry (DPASV); Simultaneous Detection; Bismuth film Electrode; Cd(II) and Pb(II); HEAVY-METAL IONS; SIMULTANEOUS ELECTROCHEMICAL DETECTION; ZEOLITIC IMIDAZOLATE FRAMEWORK; ORDERED MESOPOROUS CARBON; DIRECT CARBONIZATION; NANOPOROUS CARBONS; GRAPHENE OXIDE; POROUS CARBON; TRACE-METALS; SENSITIVE DETECTION;
D O I
10.1016/j.electacta.2014.08.021
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Recently, metal-organic frameworks (MOFs) and their carbon derivates have been demonstrated as new electrode modifying materials for electrochemical sensing. In this work, the first example of the detection of heavy metal ions with a MOF-derived sensing platform was presented. The platform was based on a glassy carbon electrode (GCE) modified by Nafion-bismuth/nitrogen doped microporous carbon (NMC) composite, in which the NMC was derived from a zeolitic imidazolate framework-8 (ZIF-8). The good dispersibility, large specific surface area (941 m(2) g(-1)), high nitrogen content (25.0 at.%) and good electrical conductivity of the NMC materials, as well as the synergistic effects of Nafion and bismuth-film contributed to the enhanced signals of the electrode during the differential pulse anodic stripping voltammetry (DPASV) measurements for simultaneous detection of trace Cd(II) and Pb(II) in aqueous solution. The calibration curves for Cd(II) covered two linear ranges varying from 2 to 10 mu g L-1 and 10 to 100 mu g L-1. As for Pb(II), the linear calibration curves ranged from 0.5 to 10 mu g L-1 and 10 to 100 mu g L-1. The detection limits were estimated to be 1.5 mu g L-1 (S/N =3) for Cd(II) and 0.05 mu g L-1 (S/N= 3) for Pb(II), which were 2 times and 200 times lower than the guideline values of drinking water given by the World Health Organization (WHO), for Cd(II) and Pb(II), respectively. In addition, the good reproducibility and stability of the modified electrode offered a promising perspective for the detection of trace metal ions in practice. Compared with other porous carbon modified electrodes that obtained by either drop-casting or screen-printing method, the proposed Nafion/Bi/NMC/GCE showed a much lower detection limit for Pb(II) and a lower or comparable detection limit for Cd(II). MoreoVer, the obtaining of uniformly ordered N-doped carbon polyhedron could shed light on the preparation of other heteroatom-doped electrode modifying materials for the detection of heavy metal ions. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:143 / 151
页数:9
相关论文
共 50 条
  • [1] Simultaneous detection of trace Cd(II) and Pb(II) by differential pulse anodic stripping voltammetry using a bismuth oxycarbide/nafion electrode
    Zhang, Yaxiao
    Li, Chao
    Su, Yingchun
    Mu, Wei
    Han, Xiaojun
    INORGANIC CHEMISTRY COMMUNICATIONS, 2020, 111
  • [2] Simultaneous determination of Cd(II) and Pb(II) by differential pulse anodic stripping voltammetry based on graphite nanofibers-Nafion composite modified bismuth film electrode
    Li, Dongyue
    Jia, Jianbo
    Wang, Jianguo
    TALANTA, 2010, 83 (02) : 332 - 336
  • [3] Simultaneous Determination of Zn(II), Cd(II), Pb(II), and Cu(II) Using Differential Pulse Anodic Stripping Voltammetry at a Bismuth Film-Modified Electrode
    Nguyen Mau Thanh
    Nguyen Van Hop
    Nguyen Dinh Luyen
    Nguyen Hai Phong
    Tran Thanh Tam Toan
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2019, 2019
  • [4] Sensitive and Selective Differential Pulse Voltammetry Detection of Cd(II) and Pb(II) Using Nitrogen-Doped Porous Carbon Nanofiber Film Electrode
    Gao, Sanshuang
    Xu, Chuyang
    Yalikun, Nuerbiya
    Mamat, Xamxikamar
    Li, Yongtao
    Wagberg, Thomas
    Hu, Xun
    Liu, Jing
    Luo, Jun
    Hu, Guangzhi
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (13) : H967 - H974
  • [5] Anodic stripping voltammetry determination of Pb(II) and Cd(II) at a bismuth/poly(aniline) film electrode
    Zhu, Wei Wei
    Li, Nian Bing
    Luo, Hong Qun
    ANALYTICAL LETTERS, 2006, 39 (11) : 2273 - 2284
  • [6] Inexpensive Bismuth-Film Electrode Supported on Pencil-Lead Graphite for Determination of Pb(II) an Cd(II) Ions by Anodic Stripping Voltammetry
    Bedin, Karen C.
    Mitsuyasu, Edson Y.
    Ronix, Amanda
    Cazetta, Andre L.
    Pezoti, Osvaldo
    Almeida, Vitor C.
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 2018
  • [7] Lithographically fabricated disposable bismuth-film electrodes for the trace determination of Pb(II) and Cd(II) by anodic stripping voltammetry
    Kokkinos, Christos
    Economou, Anastasios
    Raptis, Ioannis
    Efstathiou, Constantinos E.
    ELECTROCHIMICA ACTA, 2008, 53 (16) : 5294 - 5299
  • [8] Differential Pulse Anodic Stripping Voltammetry Detection of Cadmium with Nafion-Graphene Modified Bismuth Film Electrode
    Wu, Saiwei
    Huang, Xiaolei
    Wu, Yuhua
    Luo, Liping
    Jin, Yuancheng
    Li, Qun
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (10): : 8255 - 8262
  • [9] A Novel Tellurium Film Electrode for Simultaneous Determination of Cd(II) and Pb(II) Using Anodic Stripping Voltammetry
    Jiang, Jie
    Xu, Miao-Qing
    Liu, Jin-Feng
    Zhao, Guang-Chao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (11): : 6572 - 6579
  • [10] A study on the utility of bismuth-film electrodes for the determination of In(III) in the presence of Pb(II) and Cd(II) by square wave anodic stripping voltammetry
    Charalambous, A
    Economou, A
    ANALYTICA CHIMICA ACTA, 2005, 547 (01) : 53 - 58