Influence of pore structure on the moisture transport property of external thermal insulation composite system as studied by NMR

被引:35
|
作者
Xiong, Houren [1 ,3 ]
Yuan, Kelong [2 ]
Wen, Minjie [3 ]
Yu, Anni [1 ]
Xu, Jinming [3 ]
机构
[1] Jiaxing Univ, Bldg Energy Efficiency Technol Lab, Jiaxing 314001, Peoples R China
[2] Jiaxing Univ, Nanhu Coll, Jiaxing 314001, Peoples R China
[3] Shanghai Univ, Dept Civil Engn, Shanghai 200444, Peoples R China
关键词
External thermal insulation composite system (ETICS); NMR technique; Pores structure; Structural layer; Moisture transport; CEMENT PASTE; WATER; RELAXATION; ETICS; PERMEABILITY; POROSITY; MORTARS; RENDERS; IMPACT; VAPOR;
D O I
10.1016/j.conbuildmat.2019.116815
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to study the pore structure characteristics of the deteriorated structural layer of an external thermal insulation composite system (ETICS), the overall and stratified T-2 spectrum signals of the system made of thin-layer inorganic insulation mortar are tested by nuclear magnetic resonance (NMR) technique under different moisture transport conditions. The variation in moisture transport with pore size in the structural layer of the ETICS is studied under three conditions, namely, vacuum-saturation, free water absorption and vapor adsorption process, and indices are proposed to evaluate the vapor adsorption and free water absorption capacity of ETICS. The results indicate that the total pore volume is predominated by the pores in the insulation layer as revealed by the peaks of T-2 spectrum, which exhibit a bi-modal distribution with some larger pores. The pores in the finishing coat, protective layer and bonding layer have negligibly smaller size and smaller volume as revealed by a lower T-2 peak and an indistinct second peak. The moisture transport patterns of pores with different sizes are quite different. Vapor adsorption mainly occurs in pores of size smaller than 0.1 mu m and free water absorption mainly occurs in pores of size smaller than 10 mu m. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 49 条
  • [1] The influence of the pore structure on the moisture transport in lime plaster-brick systems as studied by NMR
    Nunes, Cristiana
    Pel, Leo
    Kunecky, Jiri
    Slizkova, Zuzana
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 142 : 395 - 409
  • [2] Determining Moisture Condition of External Thermal Insulation Composite System (ETICS) of an Existing Building
    Krause, Pawel
    Pokorska-Silva, Iwona
    Kosobucki, Lukasz
    MATERIALS, 2025, 18 (03)
  • [3] Pore structure, adsorption, and water absorption of expanded perlite mortar in external thermal insulation composite system during aging
    Xiong, Houren
    Yuan, Kelong
    Xu, Jinming
    Wen, Minjie
    CEMENT & CONCRETE COMPOSITES, 2021, 116
  • [4] The Changes of Moisture Absorption Properties during the Service Life of External Thermal Insulation Composite System
    Norvaisiene, Rosita
    Griciute, Gintare
    Bliudzius, Raimondas
    Ramanauskas, Juozas
    MATERIALS SCIENCE-MEDZIAGOTYRA, 2013, 19 (01): : 103 - 107
  • [5] Influence of External Thermal Insulation Composite Systems on External Wall Soundproofing
    Weber, Lutz
    Mueller, Simon
    Kaltbeitzel, Bernd
    BAUPHYSIK, 2018, 40 (01) : 19 - +
  • [6] Impact of Water-Repellent Products on the Moisture Transport Properties and Mould Susceptibility of External Thermal Insulation Composite Systems
    Roncon, Renata
    Borsoi, Giovanni
    Parracha, Joao L.
    Flores-Colen, Ines
    Veiga, Rosario
    Nunes, Lina
    COATINGS, 2021, 11 (05)
  • [7] Thermal and moisture performance of external thermal insulation system with periodic freezing-thawing
    Shen, Xianwen
    Li, Longjian
    Cui, Wenzhi
    Feng, Ya
    APPLIED THERMAL ENGINEERING, 2020, 181
  • [8] The influence of external thermal insulation composite systems on the summer performance of buildings
    Handler, Simon
    Korjenic, Azra
    Bednar, Thomas
    BAUPHYSIK, 2011, 33 (04) : 225 - 233
  • [9] Vibrometry Assessment of the External Thermal Composite Insulation Systems Influence on the Facade Airborne Sound Insulation
    Urban, Daniel
    Roozen, N. B.
    Muellner, Herbert
    Zat'ko, Peter
    Niemczanowski, Alexander
    Rychtarikova, Monika
    Glorieux, Christ
    APPLIED SCIENCES-BASEL, 2018, 8 (05):
  • [10] Pore structure characterization and gas transport property of the penetrating layer in composite membranes
    Li, Shichun
    Zhang, Haobin
    Yu, Shuwen
    Hou, Jingwei
    Huang, Shiliang
    Liu, Yu
    SEPARATION AND PURIFICATION TECHNOLOGY, 2019, 211 : 252 - 258