Thermodynamic stability conditions of clathrate hydrates for refrigerant (R134a or R410a or R507) with MgCl2 aqueous solution

被引:21
|
作者
Ngema, Peterson Thokozani [1 ]
Naidoo, Paramespri [1 ]
Mohammadi, Amir H. [1 ,2 ,3 ]
Richon, Dominique [1 ,4 ]
Ramjugernath, Deresh [1 ]
机构
[1] Univ KwaZulu Natal, Sch Engn, Thermodynam Res Unit, Howard Coll Campus,King George 5 Ave, ZA-4041 Durban, South Africa
[2] Univ Laval, Dept Genie Mines Met & Mat, Fac Sci & Genie, Quebec City, PQ G1V 0A6, Canada
[3] IRGCP, Paris, France
[4] Aalto Univ, Sch Sci & Technol, Dept Biotechnol & Chem Technol, Aalto, Finland
基金
新加坡国家研究基金会;
关键词
Gas hydrate; Clathrate hydrate; Desalination; Refrigerant; Dissociation data; Model; PHASE-EQUILIBRIA; CARBON-DIOXIDE; DISSOCIATION PRESSURES; SODIUM-CHLORIDE; DESALINATION; METHANE; PROPANE; ETHANE; WATER; NACL;
D O I
10.1016/j.fluid.2015.11.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
Clathrate hydrate dissociation data were measured for systems comprising of refrigerants (R134a, R410a and R507) + water + MgCl2 at varying salt concentrations. The ternary system for R134a + water + MgCl2 was measured at salt concentrations of (0.259, 0.546, and 0.868) mol.kg(-1) in the temperature range of (277.1-283) K and a pressure range of (0.114-0.428) MPa. Hydrate measurements for the {R410a or R507} + water + MgCl2 systems were measured at salt concentrations of (0.259 and 0.546) mol.kg(-1) in the temperature range of (274.3-293) K and a pressure range of (0.154-1.421) MPa. The isochoric pressure-search method was used to measure the hydrate dissociation data. This study is a continuation of previous investigations which focused on obtaining hydrate dissociation data for R134a, R410a and R507 refrigerants in NaCI and CaCl2 aqueous solutions. The measured hydrate dissociation data can be used to design industrial wastewater treatment and desalination processes. The results show that the effect of salt concentration on hydrate formation is smaller for MgCl2 aqueous solutions compared to CaCl2 and NaCl as salt concentration increases. Modelling of the measured data is performed using a combination of the solid solution theory of van der Waals and Platteeuw, the Aasberg-Petersen et al. model, and the Peng-Robinson equation of state with classical mixing rules. The model is in good agreement with the measured hydrate dissociation data. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 98
页数:7
相关论文
共 13 条
  • [1] Flow-boiling of R22, R134a, R507, R404A and R410A inside a smooth horizontal tube
    Greco, A
    Vanoli, GP
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (06): : 872 - 880
  • [2] Experimental study of R134a/R410A cascade cycle for variable refrigerant flow heat pump systems
    Jeonghun Kim
    Jaewan Lee
    Hwanjong Choi
    Sanghun Lee
    Saikee Oh
    Warn-Gyu Park
    Journal of Mechanical Science and Technology, 2015, 29 : 5447 - 5458
  • [3] Experimental study of R134a/R410A cascade cycle for variable refrigerant flow heat pump systems
    Kim, Jeonghun
    Lee, Jaewan
    Choi, Hwanjong
    Lee, Sanghun
    Oh, Saikee
    Park, Warn-Gyu
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2015, 29 (12) : 5447 - 5458
  • [4] Exergetic analysis of a vapour compression refrigeration system with R134a, R143a, R152a, R404A, R407C, R410A, R502 and R507A
    V. Siva Reddy
    N. L. Panwar
    S. C. Kaushik
    Clean Technologies and Environmental Policy, 2012, 14 : 47 - 53
  • [5] Exergetic analysis of a vapour compression refrigeration system with R134a, R143a, R152a, R404A, R407C, R410A, R502 and R507A
    Reddy, V. Siva
    Panwar, N. L.
    Kaushik, S. C.
    CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2012, 14 (01) : 47 - 53
  • [6] THERMODYNAMIC ANALYSES OF MULTIPLE EVAPORATORS VAPOR COMPRESSION REFRIGERATION SYSTEMS WITH R410A, R290, R1234YF, R502, R404A, R152A AND R134A
    Chopra, Kapil
    Sahni, V.
    Mishra, R. S.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2014, 22 (01)
  • [7] Effects of fluid properties on two-phase flow and refrigerant distribution in the vertical header of a reversible microchannel heat exchanger - Comparing R245fa, R134a, R410A, and R32
    Zou, Yang
    Hrnjak, Pega S.
    APPLIED THERMAL ENGINEERING, 2014, 70 (01) : 966 - 976
  • [8] Energy performance assessment of R1243zf/R134a, R1243zf/RE170, and R1243zf/R227ea as possible alternatives to R410A refrigerant in precision air conditioning unit
    Li, Zhiheng
    Wu, Xi
    Hu, Guanghang
    Tang, Fengyi
    Guan, Hongfei
    Zhu, Xiaojing
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2024, 46 (08)
  • [9] Investigation on absorption separation characteristics of R134a, R1234yf, R22, R410A, and R404A using MWCNT-[HMIM][Tf2N] ionanofluid
    Lee, Minjung
    Shin, Myeongjae
    Cho, Honghyun
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 47
  • [10] 绝热段阻力对CO2、R134a和R410A分离式热管传热性能的影响
    佟振
    文欣然
    韩泽坤
    房春雪
    宋玉龙
    制冷学报, 2024, 45 (04) : 28 - 35