A new hip-knee-ankle-foot sling: Kinematic comparison with a traditional ankle-foot orthosis

被引:5
|
作者
Zancan, A
Beretta, MV
Schmid, M
Schieppati, M
机构
[1] Salvatore Maugeri Fdn, Div Rehabil, Inst Care & Sci Res, I-27100 Pavia, Italy
[2] Salvatore Maugeri Fdn, Human Movement Lab, Inst Care & Sci Res, Pavia, Italy
[3] Univ Pavia, Dept Expt Med, Human Physiol Sect, Pavia, Italy
来源
关键词
AFO; gait; hemiplegia; kinematic; lower limb; orthosis; sling;
D O I
10.1682/JRRD.2003.06.0101
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
In this study, we performed a kinematic analysis of a new, low-cost sling for the lower limb, compared to a common ankle-foot orthosis (AFO). Gait with no orthosis, with the AFO, and with the new sling was analyzed in one hemiplegic subject. Both the AFO and the sling reduced the mean angle and ROM (range of movement) of the ankle and the vertical displacement of the center of mass. The sling, but not the AFO, restored the normal sequence heel-strike, forefoot contact of the affected side. The sling, but not the AFO, reduced the affected limb stance and stride duration, increased stride length, and improved walking speed. In conclusion, the proposed sling for the lower limb equally improved the affected ankle kinematics in contrast to the traditional AFO, and it also improved some gait variables in this hemiplegic subject.
引用
收藏
页码:707 / 712
页数:6
相关论文
共 50 条
  • [1] KNEE-STABILIZING ANKLE-FOOT ORTHOSIS
    RUBIN, G
    DANISI, M
    ORTHOTICS AND PROSTHETICS, 1975, 29 (03): : 11 - 14
  • [2] KINEMATIC COMPARISON OF THE BICALL ANKLE FOOT ORTHOSIS AND THE RIGID POLYPROPYLENE ANKLE FOOT ORTHOSIS IN HEMIPLEGIA
    SMITH, AE
    QUIGLEY, M
    WATERS, RL
    PHYSICAL THERAPY, 1985, 65 (05): : 714 - 714
  • [3] Biomechanical Comparison of a New Dynamic Ankle Orthosis to a Standard Ankle-Foot Orthosis During Walking
    Chung, Chloe L.
    DiAngelo, Denis J.
    Powell, Douglas W.
    Paquette, Max R.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (05):
  • [4] Energy consumption in children with myelomeningocele: A comparison between reciprocating gait orthosis and hip-knee-ankle-foot orthosis ambulators
    Cuddeford, TJ
    Freeling, RP
    Thomas, SS
    Aiona, MD
    Rex, D
    Sirolli, H
    Elliott, J
    Magnusson, M
    DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 1997, 39 (04): : 239 - 242
  • [5] Use of bivalved ankle-foot orthosis in neuropathic foot and ankle lesions
    Boninger, ML
    Leonard, JA
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1996, 33 (01): : 16 - 22
  • [6] The effect of anterior ankle-foot orthosis and posterior ankle-foot orthosis on functional ambulation in stroke patients
    Zarezadeh, Reihaneh
    Arazpour, Mokhtar
    Aminian, Gholamreza
    JOURNAL OF REHABILITATION AND ASSISTIVE TECHNOLOGIES ENGINEERING, 2022, 9
  • [7] The effect of anterior ankle-foot orthosis and posterior ankle-foot orthosis on functional ambulation in stroke patients
    Zarezadeh, Reihaneh
    Arazpour, Mokhtar
    Aminian, Gholamreza
    Journal of Rehabilitation and Assistive Technologies Engineering, 2022, 9
  • [8] Longitudinal assessment of oxygen cost and velocity in children with myelomeningocele: Comparison of the hip-knee-ankle-foot orthosis and the reciprocating gait orthosis
    Thomas, SS
    Buckon, CE
    Melchionni, J
    Magnusson, M
    Aiona, MD
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2001, 21 (06) : 798 - 803
  • [9] SEVERE ANKLE SPRAINS - TREATMENT WITH AN ANKLE-FOOT ORTHOSIS
    LANE, SE
    PHYSICIAN AND SPORTSMEDICINE, 1990, 18 (11): : 43 - &
  • [10] Design of a Hydraulic Ankle-Foot Orthosis
    Gmerek, Artur
    Meskin, Nader
    Tehrani, Ehsan Sobhani
    Kearney, Robert
    2016 6TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2016, : 1041 - 1048