Data-Driven Calibration of Soil Moisture Sensor Considering Impacts of Temperature: A Case Study on FDR Sensors

被引:14
|
作者
Chen, Liping [1 ,2 ]
Zhangzhong, Lili [1 ,2 ]
Zheng, Wengang [1 ,2 ]
Yu, JingXin [1 ,2 ]
Wang, Zehan [3 ]
Wang, Long [3 ,4 ]
Huang, Chao [3 ,4 ]
机构
[1] Natl Res Ctr Intelligent Equipment Agr, Beijing 100097, Peoples R China
[2] Minist Agr, Key Lab Qual Testing Hardware & Software Prod Agr, Beijing 100097, Peoples R China
[3] Univ Sci & Technol Beijing, Sch Comp & Commun Engn, Beijing 100083, Peoples R China
[4] Inner Mongolia Univ Technol, Key Lab Wind Energy & Solar Energy Technol, Minist Educ, Hohhot 010051, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
calibration; data-driven; impacts of temperature; soil moisture sensor; WATER-CONTENT;
D O I
10.3390/s19204381
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Commercial soil moisture sensors have been widely applied into the measurement of soil moisture content. However, the accuracy of such sensors varies due to the employed techniques and working conditions. In this study, the temperature impact on the soil moisture sensor reading was firstly analyzed. Next, a pioneer study on the data-driven calibration of soil moisture sensor was investigated considering the impacts of temperature. Different data-driven models including the multivariate adaptive regression splines and the Gaussian process regression were applied into the development of the calibration method. To verify the efficacy of the proposed methods, tests on four commercial soil moisture sensors were conducted; these sensors belong to the frequency domain reflection (FDR) type. The numerical results demonstrate that the proposed methods can greatly improve the measurement accuracy for the investigated sensors.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Study on Effect of Soil Temperature on FDR Soil Moisture Sensor in Frozen Soil
    Tian Hongwei
    Ye Linmao
    Chen Haibo
    PIAGENG 2013: INTELLIGENT INFORMATION, CONTROL, AND COMMUNICATION TECHNOLOGY FOR AGRICULTURAL ENGINEERING, 2013, 8762
  • [2] Plant root growth affects FDR soil moisture sensor calibration
    Kang, Seonghwan
    van Iersel, Marc W.
    Kim, Jongyun
    SCIENTIA HORTICULTURAE, 2019, 252 : 208 - 211
  • [3] Temperature effect on the reference frequency of FDR soil moisture sensor
    WANG Liming
    LYU Wenhua
    Instrumentation, 2015, 2 (03) : 19 - 26
  • [4] DETECTION MODEL FOR EFFECT OF SOIL SALINITY AND TEMPERATURE ON FDR MOISTURE CONTENT SENSORS
    Liu, B.
    Han, W. T.
    Weckler, P.
    Guo, W. C.
    Wang, Y.
    Song, K. X.
    APPLIED ENGINEERING IN AGRICULTURE, 2014, 30 (04) : 573 - 582
  • [5] Performance of flooded flexible pavements: A data-driven sensitivity analysis considering soil moisture fluctuations
    Ajorlou, Elham
    Mousavi, Sayedmasoud
    Ghayoomi, Majid
    Dave, Eshan, V
    TRANSPORTATION GEOTECHNICS, 2024, 45
  • [6] CALIBRATION OF WATERMARK SOIL-MOISTURE SENSORS FOR SOIL MATRIC POTENTIAL AND TEMPERATURE
    SPAANS, EJA
    BAKER, JM
    PLANT AND SOIL, 1992, 143 (02) : 213 - 217
  • [7] Data-driven calibration of tri-axial magnetic sensors
    Tian, Dongchen
    Li, Yong
    Jin, Min
    Guo, Yuxing
    Meng, Feiyang
    Liu, Qiusheng
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2025, 36 (03)
  • [8] Data-driven spatio-temporal estimation of soil moisture and temperature based on Lipschitz interpolation
    Manzano, J. M.
    Orihuela, L.
    Pacheco, E.
    Pereira, M.
    ISA TRANSACTIONS, 2025, 156 : 535 - 550
  • [9] A study on the sensor calibration method using data-driven prediction in VAV terminal unit
    Kim, Hyo-Jun
    Cho, Young-Hum
    Lee, Sang-Hoon
    ENERGY AND BUILDINGS, 2022, 258
  • [10] Real-Time Battery Temperature Monitoring Using FBG Sensors: A Data-Driven Calibration Method
    Zhang, Li
    Liu, Xuan
    Li, Kang
    Du, Dajun
    Zheng, Min
    Niu, Qun
    Yang, Yi
    Zhou, Qi
    Sun, Tong
    Grattan, Kenneth T., V