Validation of wearable visual feedback for retraining foot progression angle using inertial sensors and an augmented reality headset

被引:59
|
作者
Karatsidis, Angelos [1 ,2 ]
Richards, Rosie E. [3 ]
Konrath, JasonM. [1 ]
van den Noort, Josien C. [3 ,4 ]
Schepers, H. Martin [1 ]
Bellusci, Giovanni [1 ]
Harlaar, Jaap [3 ,5 ]
Veltink, Peter H. [2 ]
机构
[1] Xsens Technol BV, Pantheon 6, NL-7521 PR Enschede, Netherlands
[2] Univ Twente, Tech Med Ctr, Dept Biomed Signals & Syst BSS, Enschede, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, Amsterdam Movement Sci, Dept Rehabil Med, Amsterdam, Netherlands
[4] Amsterdam Movement Sci, Dept Radiol & Nucl Med, Acad Med Ctr, MIQC, Amsterdam, Netherlands
[5] Delft Univ Technol, Dept Biomech Engn, Delft, Netherlands
关键词
Foot progression angle; Inertial sensors; Real-time biofeedback; Augmented reality headset; Gait retraining; Knee osteoarthritis; KNEE ADDUCTION MOMENT; TOE-OUT GAIT; TIME BIOFEEDBACK; HAPTIC FEEDBACK; HUMAN MOVEMENT; OSTEOARTHRITIS; REDUCE; INDIVIDUALS; STRATEGIES; WALKING;
D O I
10.1186/s12984-018-0419-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Gait retraining interventions using real-time biofeedback have been proposed to alter the loading across the knee joint in patients with knee osteoarthritis. Despite the demonstrated benefits of these conservative treatments, their clinical adoption is currently obstructed by the high complexity, spatial demands, and cost of optical motion capture systems. In this study we propose and evaluate a wearable visual feedback system for gait retraining of the foot progression angle (FPA). Methods: The primary components of the system are inertial measurement units, which track the human movement without spatial limitations, and an augmented reality headset used to project the visual feedback in the visual field. The adapted gait protocol contained five different target angles ranging from 15 degrees toe-out to 5 degrees toe-in. Eleven healthy participants walked on an instrumented treadmill, and the protocol was performed using both an established laboratory visual feedback driven by optical motion capture, and the proposed wearable system. Results and conclusions: The wearable system tracked FPA with an accuracy of 2.4 degrees RMS and ICC=0.94 across all target angles and subjects, when compared to an optical motion capture reference. In addition, the effectiveness of the biofeedback, reflected by the number of steps with FPA value +/- 2 degrees from the target, was found to be around 50% in both wearable and laboratory approaches. These findings demonstrate that retraining of the FPA using wearable inertial sensing and visual feedback is feasible with effectiveness matching closely an established laboratory method. The proposed wearable setup may reduce the complexity of gait retraining applications and facilitate their transfer to routine clinical practice.
引用
收藏
页数:12
相关论文
共 27 条
  • [1] Validation of wearable visual feedback for retraining foot progression angle using inertial sensors and an augmented reality headset
    Angelos Karatsidis
    Rosie E. Richards
    Jason M. Konrath
    Josien C. van den Noort
    H. Martin Schepers
    Giovanni Bellusci
    Jaap Harlaar
    Peter H. Veltink
    Journal of NeuroEngineering and Rehabilitation, 15
  • [2] Wearable lower limb haptic feedback device for retraining Foot Progression Angle and Step Width
    Chen, Daniel K. Y.
    Haller, Markus
    Besier, Thor F.
    GAIT & POSTURE, 2017, 55 : 177 - 183
  • [3] A novel automated visual acuity test using a portable augmented reality headset
    Ong, Sze Chuan
    Pek, Ivy Li Cheng
    Chiang, Carol Tsuey Ling
    Soon, Hock Wei
    Chua, Kuang Chua
    Sassman, Chanakarn
    Koh, Victor T. C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [4] Validation of a Visual Field Test Using Tracking -Based Virtual Reality Headset
    De Sistemes, Luis
    Goyal, Diksha
    Mcguire, Allister F.
    Smith, Ashleigh
    Small, Leslie R.
    Goldberg, Jeffrey Louis
    Ang, Robert
    Azar, Dimitri T.
    Sinha, Supriyo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [5] A Practical Gait Feedback Method Based on Wearable Inertial Sensors for a Drop Foot Assistance Device
    Meng, Lin
    Martinez-Hernandez, Uriel
    Childs, Craig
    Dehghani-Sanij, Abbas A.
    Buis, Arjan
    IEEE SENSORS JOURNAL, 2019, 19 (24) : 12235 - 12243
  • [6] Foot progression angle estimation using a single foot-worn inertial sensor
    Wouda, Frank J.
    Jaspar, Stephan L. J. O.
    Harlaar, Jaap
    van Beijnum, Bert-Jan F.
    Veltink, Peter H.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2021, 18 (01)
  • [7] Foot progression angle estimation using a single foot-worn inertial sensor
    Frank J. Wouda
    Stephan L. J. O. Jaspar
    Jaap Harlaar
    Bert-Jan F. van Beijnum
    Peter H. Veltink
    Journal of NeuroEngineering and Rehabilitation, 18
  • [8] Accurate Human Navigation Using Wearable Monocular Visual and Inertial Sensors
    Tian, Ya
    Hamel, William R.
    Tan, Jindong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (01) : 203 - 213
  • [9] Validation of eye tracking-based visual tests using virtual reality headset
    De Sisternes, Luis
    Goyal, Diksha
    Azar, Dimitri
    Sinha, Supriyo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [10] Estimation of Stride Length, Foot Clearance, and Foot Progression Angle Using UWB Sensors
    Park, Ji Su
    Lee, Bohyun
    Park, Shinsuk
    Kim, Choong Hyun
    APPLIED SCIENCES-BASEL, 2023, 13 (08):