The effect of residual calcium hydroxide on the accuracy of a contemporary electronic apex locator

被引:5
|
作者
Ustun, Yakup [1 ]
Uzun, Ozgur [2 ]
Er, Ozgur [3 ]
Canakci, Burhan Can [1 ]
Topuz, Ozgur [2 ]
机构
[1] Erciyes Univ, Dept Endodont, Fac Dent, TR-38039 Kayseri, Turkey
[2] Gazi Univ, Dept Endodont, Fac Dent, Ankara, Turkey
[3] Trakya Univ, Fac Dent, Dept Endodont, Edirne, Turkey
关键词
apex locator accuracy; calcium hydroxide; endodontics; LENGTH DETERMINATION; WORKING LENGTH; IN-VIVO; ROOT; IMPEDANCE; EFFICACY; REMOVAL; TEETH;
D O I
10.3109/00016357.2014.961027
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The aim of this study was to evaluate the effect of residual calcium hydroxide [Ca(OH)(2)] on the accuracy of an electronic apex locator (EAL). Materials and methods. Working lengths (WLs) of 56 extracted maxillary incisors were determined initially by two different methods. The first method used the ` APEX' reading of the EAL as a reference point, 0.5 mm was subtracted and recorded as WL0. The second method used the '0.5' reading and the score was recorded as WL0.5 without subtraction. The roots were prepared to WL0 and divided randomly into three experimental groups (n = 16) (1 mm in group A, 2 mm in group B and 4 mm in group C) and a control (n = 8). Specimens in all experimental groups were filled with Ca(OH)(2) paste. Following its removal, WLs were re-determined with the same methods. Results. In group C, pre/ post WLs were significantly different (p < 0.05). No significant difference was observed between the other experimental groups and the control group. Conclusion. Accuracy of EAL decreased proportionally with the amount of paste remaining at the +/- 0.5-mm tolerance level. Ca(OH)(2) paste remnants may cause incorrect EAL readings.
引用
收藏
页码:132 / 136
页数:5
相关论文
共 50 条
  • [2] Accuracy of apex locator
    Vajrabhaya, L
    Tepmongkol, P
    ENDODONTICS & DENTAL TRAUMATOLOGY, 1997, 13 (04): : 180 - 182
  • [3] Accuracy of an electronic apex locator in primary teeth with root resorption
    Angwaravong, O.
    Panitvisai, P.
    INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (02) : 115 - 121
  • [4] INFLUENCE OF THE POSITION OF THE APICAL FORAMEN ON THE ACCURACY OF ELECTRONIC APEX LOCATOR
    Siddiqui, Amna Yusuf
    Alothmani, Osama Shujaa
    ANNALS OF DENTAL SPECIALTY, 2023, 11 (03): : 5 - 8
  • [5] EVALUATION OF THE ACCURACY OF THE NEOSONO-D ELECTRONIC APEX LOCATOR
    BERMAN, LH
    FLEISCHMAN, SB
    JOURNAL OF ENDODONTICS, 1984, 10 (04) : 164 - 167
  • [6] ACCURACY OF AN ELECTRONIC APEX LOCATOR - A CLINICAL-EVALUATION IN MAXILLARY MOLARS
    HEMBROUGH, JH
    WEINE, FS
    PISANO, JV
    ESKOZ, N
    JOURNAL OF ENDODONTICS, 1993, 19 (05) : 242 - 246
  • [7] Accuracy and Reliability of a New Electronic Apex Locator: an In-vivo Study
    Chita, Jair Jatoba
    da Silva, Pedro Gregol
    Souza Pereira, Key Fabiano
    Onoda, Helio Katsuya
    Borba Junior, Jose de Camargo
    Spironelli Ramos, Carlos Alberto
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2012, 12 (04): : 456 - 462
  • [8] A SEM study of in vivo accuracy of the Root ZX electronic apex locator
    Pagavino, G
    Pace, R
    Baccetti, T
    JOURNAL OF ENDODONTICS, 1998, 24 (06) : 438 - 441
  • [9] Effects of Simulated Lateral Canals on the Accuracy of Measurements by an Electronic Apex Locator
    Uzun, Ozgur
    Topuz, Ozgur
    Aslan, Seda
    Tinaz, Ali Cemal
    JOURNAL OF THE CANADIAN DENTAL ASSOCIATION, 2012, 78 : 1 - 7
  • [10] The evaluation of the accuracy of a wireless electronic apex locator in primary molar teeth
    Oncu, Aysenur
    Sisko, Ecem
    Demirel, Akif
    Celikten, Berkan
    BMC ORAL HEALTH, 2024, 24 (01):