Comparison of minimal residual disease detection in multiple myeloma between SRL 8-color single-tube and EuroFlow 8-color 2-tube multiparameter flow cytometry methods

被引:0
|
作者
Takamatsu, Hiroyuki [1 ]
Yoroidaka, Takeshi [1 ]
Fujisawa, Momoko [1 ]
Kobori, Kazuya [2 ]
Hanawa, Masako [2 ]
Yamashita, Takeshi [3 ]
Murata, Ryoichi [3 ]
Ueda, Mikio [3 ]
Nakao, Shinji [1 ]
Matsue, Kosei [4 ]
机构
[1] Kanazawa Univ, Kanazawa, Ishikawa, Japan
[2] SRL Inc, Tokyo, Japan
[3] Keiju Kanazawa Hosp, Kanazawa, Ishikawa, Japan
[4] Kameda Med Ctr, Kamogawa, Japan
来源
CLINICAL LYMPHOMA MYELOMA & LEUKEMIA | 2019年 / 19卷 / 10期
关键词
Minimal residual disease; multiparameter flow cytometry;
D O I
10.1016/j.clml.2019.09.307
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
FP-222
引用
收藏
页码:E183 / E184
页数:2
相关论文
共 50 条
  • [1] Comparison of minimal residual disease detection in multiple myeloma by SRL 8-color single-tube and EuroFlow 8-color 2-tube multiparameter flow cytometry
    Hiroyuki Takamatsu
    Takeshi Yoroidaka
    Momoko Fujisawa
    Kazuya Kobori
    Masako Hanawa
    Takeshi Yamashita
    Ryoichi Murata
    Mikio Ueda
    Shinji Nakao
    Kosei Matsue
    International Journal of Hematology, 2019, 109 : 377 - 381
  • [2] Correction to: Comparison of minimal residual disease detection in multiple myeloma by SRL 8-color single-tube and EuroFlow 8-color 2-tube multiparameter flow cytometry
    Hiroyuki Takamatsu
    Takeshi Yoroidaka
    Momoko Fujisawa
    Kazuya Kobori
    Masako Hanawa
    Takeshi Yamashita
    Ryoichi Murata
    Mikio Ueda
    Shinji Nakao
    Kosei Matsue
    International Journal of Hematology, 2019, 109 : 505 - 505
  • [3] Comparison of minimal residual disease detection in multiple myeloma by SRL 8-color single-tube and EuroFlow 8-color 2-tube multiparameter flow cytometry (vol 109, pg 377, 2019)
    Takamatsu, Hiroyuki
    Yoroidaka, Takeshi
    Fujisawa, Momoko
    Kobori, Kazuya
    Hanawa, Masako
    Yamashita, Takeshi
    Murata, Ryoichi
    Ueda, Mikio
    Nakao, Shinji
    Matsue, Kosei
    INTERNATIONAL JOURNAL OF HEMATOLOGY, 2019, 109 (04) : 505 - 505
  • [4] MRD detection in multiple myeloma: comparison between MSKCC 10-color single-tube and EuroFlow 8-color 2-tube methods
    Roshal, Mikhail
    Flores-Montero, Juan A.
    Gao, Qi
    Koeber, Maesa
    Wardrope, Jessica
    Durie, Brian G. M.
    Dogan, Ahmet
    Orfao, Alberto
    Landgren, Ola
    BLOOD ADVANCES, 2017, 1 (12) : 728 - 732
  • [5] Minimal residual disease detection in multiple myeloma: comparison between BML single-tube 10-color multiparameter flow cytometry and EuroFlow multiparameter flow cytometry
    Sato, Kota
    Okazuka, Kiyoshi
    Ishida, Tadao
    Sakamoto, Jun
    Kaneko, Shigeto
    Nashimoto, Junichiro
    Uto, Yui
    Ogura, Mizuki
    Yoshiki, Yumiko
    Abe, Yu
    Maeda, Aki
    Hamazaki, Hiroyuki
    Tsukada, Nobuhiro
    Hiragohri, Yuji
    Suzuki, Kenshi
    ANNALS OF HEMATOLOGY, 2021, 100 (12) : 2989 - 2995
  • [6] Minimal residual disease detection in multiple myeloma: comparison between BML single-tube 10-color multiparameter flow cytometry and EuroFlow multiparameter flow cytometry
    Kota Sato
    Kiyoshi Okazuka
    Tadao Ishida
    Jun Sakamoto
    Shigeto Kaneko
    Junichiro Nashimoto
    Yui Uto
    Mizuki Ogura
    Yumiko Yoshiki
    Yu Abe
    Aki Maeda
    Hiroyuki Hamazaki
    Nobuhiro Tsukada
    Yuji Hiragohri
    Kenshi Suzuki
    Annals of Hematology, 2021, 100 : 2989 - 2995
  • [7] Comparison of Minimal Residual Disease Detection in Autografts of Patients with Multiple Myeloma between 8-Color Multiparameter Flow Cytometry (EuroFlow) and Next-Generation Sequencing
    Takamatsu, Hiroyuki
    Takezako, Naoki
    Wee, Rachel K.
    Yoroidaka, Takeshi
    Yamashita, Takeshi
    Murata, Ryoichi
    Matsue, Kosei
    Nakao, Shinji
    BLOOD, 2018, 132
  • [8] Minimal Residual Disease in Autografts and Bone Marrow of Patients with Multiple Myeloma: 8-Color Multiparameter Flow Cytometry (EuroFlow- NGF) Vs. Next-Generation Sequencing
    Takamatsu, Hiroyuki
    Takezako, Naoki
    Yoroidaka, Takeshi
    Yamashita, Takeshi
    Murata, Ryoichi
    Yamazaki, Atsuko
    Takeuchi, Masahiro
    Mimura, Naoya
    Nakaseko, Chiaki
    Sakaida, Emiko
    Onoda, Masahiro
    Utsu, Yoshikazu
    Fukazawa, Motoharu
    Matsue, Kosei
    Nakao, Shinji
    BLOOD, 2020, 136
  • [9] Optimization and Validation of an 8-Color Single-Tube Assay for the Sensitive Detection of Minimal Residual Disease in B-Cell Chronic Lymphocytic Leukemia Detected via Flow Cytometry
    Dowling, Anita K.
    Liptrot, Stuart D.
    O'Brien, David
    Vandenberghe, Elisabeth
    LABORATORY MEDICINE, 2016, 47 (02) : 103 - 111
  • [10] MONITORING OF MINIMAL RESIDUAL DISEASE IN MULTIPLE MYELOMA BY A SINGLE-TUBE 10-COLOR FLOW CYTOMETRY
    Shen, Wenhong
    Dai, Lan
    He, Yang
    Zhu, Mingqing
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 : 107 - 107