NIST mixed stain study 3: DNA quantitation accuracy and its influence on short tandem repeat multiplex signal intensity

被引:34
|
作者
Kline, MC [1 ]
Duewer, DL [1 ]
Redman, JW [1 ]
Butler, JM [1 ]
机构
[1] Natl Inst Stand & Technol, Chem Sci & Technol Lab, Gaithersburg, MD 20899 USA
关键词
D O I
10.1021/ac026410i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The Mixed Stain Study 3 (MSS3) interlaboratory challenge exercise evaluated the 2001 performance of STR multiplex DNA typing systems using a set of seven DNA extracts of designed concentration and composition. This initial report focuses on the linkages connecting the measurement of the concentration of DNA ([DNA]) to the observed STR multiplex signal intensities. There is a causal relationship between [DNA] measurement accuracy and the efficiency of STR multiplex analysis. There are no intrinsic measurement performance differences among the [DNA] measurement technologies reported. However, there are large differences in the efficiencies of amplification, separation, and detection among participants using the same nominal measurement systems.
引用
收藏
页码:2463 / 2469
页数:7
相关论文
共 5 条
  • [1] NIST Mixed Stain Study 3: Signal intensity balance in commercial short tandem repeat multiplexes
    Duewer, DL
    Kline, MC
    Redman, JW
    Butler, JM
    ANALYTICAL CHEMISTRY, 2004, 76 (23) : 6928 - 6934
  • [2] NIST mixed stain studies #1 and #2: Interlaboratory comparison of DNA quantification practice and short tandem repeat multiplex performance with multiple-source samples
    Duewer, DL
    Kline, MC
    Redman, JW
    Newall, PJ
    Reeder, DJ
    JOURNAL OF FORENSIC SCIENCES, 2001, 46 (05) : 1199 - 1210
  • [3] Selective blood-DNA extraction from mixed stain using ABO antibody for short tandem repeat typing
    Honda, Katsuya
    Yano, Shizue
    Nishi, Takeki
    Iwabuchi, Yayoi
    Kurosu, Akira
    Sugano, Yukiko
    FORENSIC SCIENCE INTERNATIONAL GENETICS SUPPLEMENT SERIES, 2013, 4 (01) : E326 - E327
  • [4] Multiplex short tandem repeat DNA analysis confirms the accuracy of p57KIP2 immunostaining in the diagnosis of complete hydatidiform mote
    Popiolek, Dorota A.
    Yee, Herman
    Mittal, Khush
    Chiriboga, Luis
    Prinz, Mechthild K.
    Caragine, Theresa A.
    Budimlija, Zoran M.
    HUMAN PATHOLOGY, 2006, 37 (11) : 1426 - 1434
  • [5] Population study of the Combined DNA Index System (CODIS) core loci D3S1358, D5S818, D8S1179 short tandem repeat (STR) polymorphisms in Sri Lanka
    Chatumal, W.
    Markalanda, Dinuka A.
    Illeperuma, Ruwan J.
    Ranawaka, Gaya R.
    Fernandopulle, Neil D.
    JOURNAL OF THE NATIONAL SCIENCE FOUNDATION OF SRI LANKA, 2010, 38 (01): : 65 - 68