Intracranial Distribution of Intravenously Administered Gadolinium-based Contrast Agent over a Period of 24 Hours: Evaluation with 3D-real IR Imaging and MR Fingerprinting

被引:15
|
作者
Naganawa, Shinji [1 ]
Ito, Rintaro [1 ]
Kato, Yutaka [1 ]
Kawai, Hisashi [1 ]
Taoka, Toshiaki [1 ]
Yoshida, Tadao [2 ]
Maruyama, Katsuya [3 ]
Murata, Katsutoshi [3 ]
Koerzdoerfer, Gregor [4 ]
Pfeuffer, Josef [4 ]
Nittka, Mathias [4 ]
Sone, Michihiko [2 ]
机构
[1] Nagoya Univ, Dept Radiol, Grad Sch Med, Nagoya, Aichi, Japan
[2] Nagoya Univ, Dept Otorhinolaryngol, Grad Sch Med, Nagoya, Aichi, Japan
[3] Siemens Healthcare KK, Tokyo, Japan
[4] Siemens Healthcare GmbH, Erlangen, Germany
关键词
magnetic resonance imaging; magnetic resonance fingerprinting; gadolinium; glymphatic system; ENDOLYMPHATIC HYDROPS; CEREBROSPINAL-FLUID; MENIERES-DISEASE; BRAIN; ENHANCEMENT; PATHWAY; SPACE; VISUALIZATION; 3D-FLAIR; MEDIA;
D O I
10.2463/mrms.mp.2020-0030
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility for the detection of slight contrast effects after intravenous administration of single dose gadolinium-based contrast agent (IV-SD-GBCA), the time course of the GBCA distribution up to 24 h was examined in various fluid spaces and brain parenchyma using 3D-real IR imaging and MR fingerprinting (MRF). Methods: Twenty-four patients with a suspicion of endolymphatic hydrops were scanned at pre-administration and at 10 min, 4 and 24 h post-IV-SD-GBCA. 3D-real IR images and MRF at the level of the internal auditory canal were obtained. The signal intensity on the 3D-real IR image of the cerebrospinal fluid (CSF) in the cerebellopontine angle cistern (CPA), Sylvian fissure (Syl), lateral ventricle (LV), and cochlear perilymph (CPL) was measured. The T-1 and T-2 values of cerebellar gray (GM) and white matter (WM) were measured using MRF. Each averaged value at the various time points was compared using an analysis of variance. Results: The signal intensity on the 3D-real IR image in each CSF region peaked at 4 h, and was decreased significantly by 24 h (P < 0.05). All patients had a maximum signal intensity at 4 h in the CPA, and Syl. The mean CPL signal intensity peaked at 4 h and decreased significantly by 24 h (P < 0.05). All patients but two had a maximum signal intensity at 4 h. Regarding the T-1 value in the cerebellar WM and GM, the T-1 value at 10 min post-IV-GBCA was significantly decreased compared to the pre-contrast scan, but no significant difference was observed at the other time points. There was no significant change in T-2 in the gray or white matter at any of the time points. Conclusion: Time course of GBCA after IV-SD-GBCA could be evaluated by 3D-real IR imaging in CSF spaces and in the brain by MRF.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 3 条
  • [1] Quantification of Endolymphatic Space Volume after Intravenous Administration of a Single Dose of Gadolinium-based Contrast Agent: 3D-real Inversion Recovery versus HYDROPS-Mi2
    Ohashi, Toshio
    Naganawa, Shinji
    Takeuchi, Ai
    Katagiri, Toshio
    Kuno, Kayao
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (02) : 119 - 124
  • [2] Reliable detection of coronary stenoses with contrast enhanced, 3D free breathing coronary MR angiography using a gadolinium-based intravascular contrast agent
    Paetsch, I
    Huber, ME
    Bornstedt, A
    Cavagna, F
    Schnackenburg, B
    Boesiger, P
    Stuber, M
    Nagel, E
    Fleck, E
    CIRCULATION, 2003, 108 (17) : 488 - 488
  • [3] Intratumoral evaluation of 3D microvasculature and nanoparticle distribution using a gadolinium-dendron modified nano-liposomal contrast agent with magnetic resonance micro-imaging
    Nitta, Nobuhiro
    Takakusagi, Yoichi
    Kokuryo, Daisuke
    Shibata, Sayaka
    Tomita, Akihiro
    Higashi, Tatsuya
    Aoki, Ichio
    Harada, Masafumi
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2018, 14 (04) : 1315 - 1324