OBJECTIVE. Hypertension is common in the pediatric population. There is increasing evidence for early hypertensive target organ damage that may lead to substantial long- term morbidity. Because a critical aspect of any screening program for hypertension is the ability to measure blood pressure accurately, we compared typical blood pressure measurements at a vital sign station with those that were obtained following recommendations set forth in " The Fourth Report on the Diagnosis, Evaluation, and Treatment of High Blood Pressure in Children and Adolescents." METHODS. We compared the blood pressure measurements that were obtained with standard practice vital sign station screening with those that were obtained by trained personnel in accordance with Fourth Task Force recommendations. A total of 390 children were evaluated at 580 visits to the Pediatric Hypertension Clinic at Texas Children's Hospital. RESULTS. Seventy- four percent of the readings were higher at the vital sign station, and only 12% differed by < 5 mm Hg for both systolic blood pressure and diastolic blood pressure. The mean difference between vital sign station and examination room was 13.2 +/- 8.9 mm Hg for systolic blood pressure and 9.6 +/- 7.6 mm Hg for diastolic blood pressure. Multiple regression analyses revealed that age, gender, race, obesity, first versus subsequent visit, essential versus secondary, or white coat hypertension and antihypertensive medications made no statistically significant difference in the lack of correlation of the readings. CONCLUSION. These results suggest that if pediatricians use vital sign station screening for blood pressure, children with elevated initial measurements must be reevaluated in the examination room.
引用
收藏
页码:E538 / E543
页数:6
相关论文
共 50 条
  • [1] Inaccuracy of blood pressure measurement: themysterious role of arterial stiffness
    Papaioannou, Theodore G.
    Vrachatis, Dimitrios A.
    Tsioufis, Costas
    JOURNAL OF HYPERTENSION, 2022, 40 (01) : 194 - 194
  • [2] Blood Pressure Measurement in Different Outpatient Clinics
    Silva, Ricardo Pereira
    Lima, Jose Wellington
    Medeiros, Raul Pinheiro
    Ribeiro Filho, Haroldo Heitor
    de Oliveira Filgueira, Pedro Henrique
    da Silva, Geraldo Bezerra, Jr.
    Barbosa de Lima, Ramon Rawache
    Martins Rodrigues Sobrinho, Carlos Roberto
    KIDNEY & BLOOD PRESSURE RESEARCH, 2010, 33 (03): : 235 - 239
  • [3] INACCURACY OF 7 POPULAR SPHYGMOMANOMETERS FOR HOME MEASUREMENT OF BLOOD-PRESSURE
    OBRIEN, E
    MEE, F
    ATKINS, N
    OMALLEY, K
    JOURNAL OF HYPERTENSION, 1990, 8 (07) : 621 - 634
  • [4] BLOOD PRESSURE MEASUREMENT IN SHOCK - MECHANISM OF INACCURACY IN AUSCULTATORY AND PALPATORY METHODS
    COHN, JN
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1967, 199 (13): : 972 - &
  • [6] Standardization of blood pressure measurement in a geriatric outpatient clinic
    Sheng, B
    Dickinson, JA
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2003, 51 (07) : 1042 - 1043
  • [7] MEASUREMENT OF THE INACCURACY OF ESOPHAGEAL PRESSURE FOR PLEURAL PRESSURE ESTIMATION
    DRUMMOND, GB
    WRIGHT, ADG
    BRITISH JOURNAL OF ANAESTHESIA, 1982, 54 (02) : P230 - P230
  • [8] Blood pressure measurement in the outpatient clinic: When should it be done?
    Tschumi, S.
    SWISS MEDICAL WEEKLY, 2010, 140 (21-22) : 13S - 13S
  • [9] Recognition of Elevated Blood Pressure in an Outpatient Pediatric Tertiary Care Setting
    Beacher, Daniel R.
    Chang, Sheila Z.
    Rosen, Joshua S.
    Lipkin, Genna S.
    McCarville, Megan M.
    Quadri-Sheriff, Maheen
    Kwon, Soyang
    Lane, Jerome C.
    Binns, Helen J.
    Ariza, Adolfo J.
    JOURNAL OF PEDIATRICS, 2015, 166 (05): : 1233 - U456
  • [10] UNATTENDED AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT VERSUS CLASSIC OFFICE AUTOMATED BLOOD PRESSURE MEASUREMENT IN A HYPERTENSION OUTPATIENT CLINIC
    Legrady, Peter
    Fejes, Imola
    Czombos, Andras
    Abraham, Gyorgy
    JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E99 - E99