Multistage Adaptive Noise Cancellation Scheme for Heart Rate Estimation From PPG Signal Utilizing Mode Based Decomposition of Acceleration Data

被引:4
|
作者
Talukdar, Md. Toky Foysal [1 ]
Pathan, Naqib Sad [2 ]
Fattah, Shaikh Anowarul [1 ]
Quamruzzaman, Muhammad [2 ]
Saquib, Mohammad [3 ]
机构
[1] Bangladesh Univ Engn & Technol, Dept Elect & Elect Engn, Dhaka 1000, Bangladesh
[2] Chittagong Univ Engn & Technol, Dept Elect & Elect Engn, Chattogram 4349, Bangladesh
[3] Univ Texas Dallas, Dept Elect Engn, Richardson, TX 75080 USA
关键词
Heart rate; Accelerometers; Estimation; Frequency estimation; Noise reduction; Noise cancellation; Motion artifacts; Acceleration data; adaptive noise cancellation (ANC); empirical mode decomposition (EMD); heart rate; motion artifacts; photoplethysmography (PPG); variational mode decomposition (VMD); PHOTOPLETHYSMOGRAPHIC SIGNALS; PHYSICAL-EXERCISE; FRAMEWORK;
D O I
10.1109/ACCESS.2022.3168742
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Photoplethysmography (PPG) has recently become a popular method for heart rate estimation due to its simple acquisition technique. However, the main challenge in determining the heart rate from the PPG signals is its high vulnerability to motion artifacts (MA). In this paper, a new scheme is proposed for heart rate estimation through frame selective multistage adaptive noise cancellation (MANC). The frame selective approach determines the specific frames of PPG signal which are significantly interfered with MA, and the MA removal operation is only employed over those specific frames. The MANC scheme is implemented through the Least Mean Square (LMS) algorithm in which instead of the conventional approach of using accelerometer data directly, we propose to utilize mode-based decomposed 3-channel accelerometer data as reference signals independently in a sequential manner. The use of decomposed modes offers high degrees of controllability in the ANC scheme depending on the overlap between the spectra corresponding to MA and heart rate, thereby offers effective denoising. A peak searching algorithm is employed to estimate heart rate-related peaks from the resulting noise-reduced PPG signal. The novelty of the proposed scheme lies in the use of decomposed reference inputs to the MANC algorithm (named as DERMANC scheme) which is accomplished through both empirical mode decomposition (EMD) and variational mode decomposition (VMD). Performance of the proposed EMD and VMD based schemes (E-DERMANC and V-DERMANC) has been tested on a publicly available dataset and very satisfactory results are obtained in terms of estimation accuracy and computational time (0.95 and 1.10 BPM, respectively on 12 recordings) that makes the schemes worthy to be implemented in wearable devices.
引用
收藏
页码:59759 / 59771
页数:13
相关论文
共 50 条
  • [1] Denoising of ECG Signal Based on Empirical Mode Decomposition and Adaptive Noise Cancellation
    Yang, Rendi
    Zhang, Yanli
    ADVANCES IN SCIENCE AND ENGINEERING, PTS 1 AND 2, 2011, 40-41 : 140 - +
  • [2] Adaptive noise cancellation using accelerometers for the PPG signal from forehead
    Kim, Sang Hyun
    Ryoo, Dong Wan
    Bae, Changseok
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2564 - +
  • [3] CASINOR: Combination of adaptive filters using single noise reference signal for heart rate estimation from PPG signals
    K. R. Arunkumar
    M. Bhaskar
    Signal, Image and Video Processing, 2020, 14 : 1507 - 1515
  • [4] CASINOR: Combination of adaptive filters using single noise reference signal for heart rate estimation from PPG signals
    Arunkumar, K. R.
    Bhaskar, M.
    SIGNAL IMAGE AND VIDEO PROCESSING, 2020, 14 (08) : 1507 - 1515
  • [5] Estimation of Pulse Rate from Ambulatory PPG using Ensemble Empirical Mode Decomposition and Adaptive Thresholding
    Pittara, Melpo
    Theocharides, Theocharis
    Orphanidou, Christina
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 2916 - 2919
  • [6] Real-Time Robust Heart Rate Estimation From Wrist-Type PPG Signals Using Multiple Reference Adaptive Noise Cancellation
    Chowdhury, Sayeed Shafayet
    Hyder, Rakib
    Bin Hafiz, Md. Samzid
    Haque, Mohammad Ariful
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (02) : 450 - 459
  • [7] Robust Heart Rate Estimate from PPG Signal Utilizing The Harmonic Analysis of Motion Signal
    Hasan, Zahid
    Haque, Mohammad Ariful
    TENCON 2015 - 2015 IEEE REGION 10 CONFERENCE, 2015,
  • [8] Heart rate extraction from PPG signals using variational mode decomposition
    Sharma, Hemant
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2019, 39 (01) : 75 - 86
  • [9] A cascaded approach of group sparse mode decomposition and deep neural network for heart rate estimation using reference signal-less PPG signal
    Pankaj
    Maan, Pratibha
    Kumar, Manjeet
    Kumar, Ashish
    Komaragiri, Rama
    MEASUREMENT, 2025, 246
  • [10] Heart Rate Estimation from Wrist PPG Signal During Intense Physical Exercise
    Hasan K.
    Chowdhury M.H.
    Pathan N.S.
    Hossain Q.D.
    SN Computer Science, 4 (5)