Reduction of spectral ghost artifacts in high-resolution echo-planar spectroscopic Imaging of water and fat resonances

被引:33
|
作者
Du, WL
Du, YP
Fan, XB
Zamora, MA
Karczmar, GS
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Colorado, Hlth Sci Ctr, Dept Psychiat & Radiol, Denver, CO 80262 USA
关键词
artifact; odd and even echoes; echo-planar spectroscopic imaging; spectral ghost artifacts; high spectral and spatial resolution imaging;
D O I
10.1002/mrm.10485
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Echo-planar spectroscopic imaging (EPSI) can be used for fast spectroscopic imaging of water and fat resonances at high resolution to improve structural and functional imaging. Because of the use of oscillating gradients during the free induction decay (FID), spectra obtained with EPSI are often degraded by Nyquist ghost artifacts arising from the inconsistency between the odd and even echoes. The presence of the spectral ghost lines causes errors in the evaluation of the true spectral lines, and this degrades images derived from high-resolution EPSI data. A technique is described for reducing the spectral ghost artifacts in EPSI of water and fat resonances, using echo shift and zero-order phase corrections. These corrections are applied during the data postprocessing. This technique is demonstrated with EPSI data acquired from human brains and breasts at 1.5 Tesla and from a water phantom at 4.7 Tesla. Experimental results indicate that the present approach significantly reduces the intensities of spectral ghosts. This technique is most useful in conjunction with high-resolution EPSI of water and fat resonances, but is less applicable to EPSI of metabolites due to the complexity of the spectra. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:1113 / 1120
页数:8
相关论文
共 50 条
  • [1] Assessment of spectral ghost artifacts in echo-planar spectroscopic micro-imaging with flyback readout
    Weis, Jan
    Babos, Magor
    Estrada, Sergio
    Selvaraju, Ram Kumar
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [2] High-Resolution Echo-Planar Spectroscopic Imaging of the Human Calf
    Weis, Jan
    Bruvold, Morten
    Ortiz-Nieto, Francisco
    Ahlstrom, Hakan
    PLOS ONE, 2014, 9 (01):
  • [3] High-resolution echo-planar spectroscopic imaging at ultra-high field
    Coello, Eduardo
    Noeske, Ralph
    Burns, Brian L.
    Gordon, Jeremy W.
    Jakary, Angela
    Menze, Bjoern
    Haase, Axel
    Larson, Peder E. Z.
    Li, Yan
    Schulte, Rolf F.
    NMR IN BIOMEDICINE, 2018, 31 (11)
  • [4] TECHNIQUES FOR HIGH-RESOLUTION ECHO-PLANAR MR IMAGING OF THE PANCREAS
    REIMER, P
    SAINI, S
    HAHN, PF
    MUELLER, PR
    BRADY, TJ
    COHEN, MS
    RADIOLOGY, 1992, 182 (01) : 175 - 179
  • [5] Comparison of high-resolution echo-planar spectroscopic imaging with conventional MR imaging of prostate tumors in mice
    Du, WL
    Fan, XB
    Foxley, S
    Zamora, M
    River, JN
    Culp, RM
    Karczmar, GS
    NMR IN BIOMEDICINE, 2005, 18 (05) : 285 - 292
  • [6] Anatomical and functional brain imaging using high-resolution echo-planar spectroscopic imaging at 1.5 Tesla
    Du, WL
    Karczmar, GS
    Uftring, SJ
    Du, YPP
    NMR IN BIOMEDICINE, 2005, 18 (04) : 235 - 241
  • [7] Quantification and reduction of ghosting artifacts in interleaved echo-planar imaging
    Reeder, SB
    Atalar, E
    Bolster, BD
    McVeigh, ER
    MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) : 429 - 439
  • [8] High-resolution echo-planar imaging of the brain: Is it suitable for routine clinical imaging?
    Ozdoba, C
    Remonda, L
    Heid, O
    Lovblad, KO
    Schroth, G
    NEURORADIOLOGY, 1997, 39 (12) : 833 - 840
  • [9] High-resolution echo-planar imaging of the brain: is it suitable for routine clinical imaging?
    C. Ozdoba
    L. Remonda
    O. Heid
    K.-O. Lövblad
    G. Schroth
    Neuroradiology, 1997, 39 : 833 - 840
  • [10] High-resolution 31P echo-planar spectroscopic imaging in vivo at 7T
    Korzowski, Andreas
    Bachert, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1251 - 1259