Reduction of Laboratory Utilization in the Intensive Care Unit

被引:16
|
作者
Raad, Samih [1 ]
Elliott, Rachel [2 ]
Dickerson, Evan [3 ]
Khan, Babar [4 ]
Diab, Khalil [4 ]
机构
[1] Indiana Univ Sch Med, Dept Internal Med, Indianapolis, IN 46202 USA
[2] IU Hlth Univ Hosp, Indianapolis, IN USA
[3] Indiana Univ Hlth, Clin Innovat & Efficiency Financial Planning & An, Indianapolis, IN USA
[4] Indiana Univ Sch Med, Dept Internal Med, Div Pulm Crit Care Sleep & Occupat Med, Gath Hall,CL 260,1120 W Michigan St, Indianapolis, IN 46202 USA
关键词
intensive care; medical care costs; clinical laboratory services; radiography; thoracic; cost savings; patient satisfaction; US HEALTH-CARE; BLOOD-LOSS; TESTS; LACTATE; SEPSIS;
D O I
10.1177/0885066616651806
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: In our academic intensive care unit (ICU), there is excess ordering of routine laboratory tests. This is partially due to a lack of transparency of laboratory-processing costs and to the admission order plans that favor daily laboratory test orders. We hypothesized that a program that involves physician and staff education and alters the current ICU order sets will lead to a sustained decrease in routine laboratory test ordering. Design: Prospective cohort study. Setting: Academic closed medical ICU (MICU). Patients: All patients admitted to the MICU. Methods: We consistently educated residents, faculty, and staff about laboratory test costs. We removed the daily laboratory test option from the admission order sets and asked residents to order needed laboratory test results every day. We only allowed the G3+I-STAT (arterial blood gas only) cartridges in the MICU in hopes of decreasing duplicative laboratory test results. We added laboratory review to the daily rounding checklist. Measurement and Main Results: Total number of laboratory tests per patient-day decreased from 39.43 to an average of 26.74 (P <.001) over a 9-month period. The number of iSTAT laboratory tests per patient-day decreased from 7.37 to an average of 1.16 (P < .001) over the same time period. The number of iSTAT/central laboratory processing duplicative laboratory tests per patient-day decreased from 0.17 to an average of 0.01 (P < .001). The percentage of patients who have daily laboratory test orders decreased from 100% to an average of 11.94% (P <. 001). US$123 436 in direct savings and US$258 035 dollars in indirect savings could be achieved with these trends. Intensive care unit morbidity and mortality were not impacted. Conclusion: A simple technique of resident, nursing, and ancillary staff education, combined with alterations in order sets using electronic medical records, can lead to a sustained reduction in laboratory test utilization over time and to significant cost savings without affecting patient safety.
引用
收藏
页码:500 / 507
页数:8
相关论文
共 50 条
  • [1] Reducing Unnecessary Laboratory Utilization in the Medical Intensive Care Unit
    Story, R.
    Conroy, M.
    Homsy, E.
    Johns, J.
    Patterson, K.
    Singha, A.
    Cape, K.
    Exline, M. C.
    Ali, N. A.
    Gephart, M.
    Faherty, K.
    Besecker, B. Y.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [2] Optimizing Utilization of Laboratory Investigations in Neonatal Intensive Care Unit
    Devarapalli, Sowmya
    Saini, Shiv Sajan
    Sundaram, Venkataseshan
    Kumar, Praveen
    INDIAN PEDIATRICS, 2018, 55 (09) : 784 - 787
  • [3] Optimizing Utilization of Laboratory Investigations in Neonatal Intensive Care Unit
    Sowmya Devarapalli
    Shiv Sajan Saini
    Venkataseshan Sundaram
    Praveen Kumar
    Indian Pediatrics, 2018, 55 : 784 - 787
  • [4] Successful reduction of urinary catheter utilization in a Pediatric Intensive Care Unit
    McCaffrey, Laura
    Forkan-Kelly, Sinead
    Frick, Heather
    Gharpure, Varsha
    CRITICAL CARE MEDICINE, 2013, 41 (12)
  • [5] Utilization of intensive care unit technology
    Ahrens, T
    NEW HORIZONS-THE SCIENCE AND PRACTICE OF ACUTE MEDICINE, 1998, 6 (01): : 41 - 51
  • [6] ANTIPSYCHOTIC UTILIZATION IN THE INTENSIVE CARE UNIT
    Marshall, John
    Stevens, Jennifer
    Kats, Julia
    Howell, Michael
    CRITICAL CARE MEDICINE, 2012, 40 (12) : U258 - U258
  • [7] Laboratory testing in the intensive care unit
    Ezzie, Michael E.
    Aberegg, Scott K.
    O'Brien, James M., Jr.
    CRITICAL CARE CLINICS, 2007, 23 (03) : 435 - +
  • [8] Decreased laboratory utilization in an "intensivist managed" surgical intensive care unit: A prospective study
    Haut, ER
    Gracias, VH
    Sicoutris, CP
    Meredith, DM
    Reilly, PM
    Auerbach, S
    Sonnad, SS
    Hanson, CW
    Schwab, CW
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2004, 199 (03) : S75 - S76
  • [9] Antipsychotic utilization in the intensive care unit and in transitions of care
    Marshall, John
    Herzig, Shoshana J.
    Howell, Michael D.
    Le, Stephen H.
    Mathew, Chris
    Kats, Julia S.
    Stevens, Jennifer P.
    JOURNAL OF CRITICAL CARE, 2016, 33 : 119 - 124
  • [10] Utilization of intensive care unit days in a Canadian medical-surgical intensive care unit
    Wong, DT
    Gomez, M
    McGuire, GP
    Kavanagh, B
    CRITICAL CARE MEDICINE, 1999, 27 (07) : 1319 - 1324