High-speed off-axis Cavity Ring-Down Spectroscopy with a re-entrant configuration for spectral resolution enhancement

被引:11
|
作者
Courtois, Jeremie [1 ]
Mohamed, Ajmal Khan [1 ]
Romanini, Daniele [2 ]
机构
[1] Off Natl Etud & Rech Aerosp, F-91761 Palaiseau, France
[2] CNRS, Spectrometrie Phys Lab, F-38402 St Martin Dheres, France
来源
OPTICS EXPRESS | 2010年 / 18卷 / 05期
关键词
OPTICAL CAVITY; ABSORPTION-SPECTROSCOPY; DIODE-LASER; FINESSE; SPECTROMETER;
D O I
10.1364/OE.18.004845
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Monitoring of changing samples by Cavity Ring-Down Spectroscopy (CRDS) is possible using fast frequency scans of the laser and/or the cavity resonance. Mode-matched cavity excitation improves performance of fast CRDS but data-points result separated by the cavity Free Spectral Range (FSR): low pressure samples demand long cavities. We demonstrate fast CRDS with off-axis injection of a "re-entrant" resonator yielding FSR/N data-points separation. Our N = 4 short-cavity setup is found to perform well compared with other fast-CRDS implementations. Interestingly, the intrinsic chirped ringing affecting ring-down signals in mode-matched fast-CRDS disappear with off-axis injection. This is due to a fine splitting of the re-entrant-cavity degenerate groups of modes by astigmatism. (C) 2010 Optical Society of America
引用
收藏
页码:4845 / 4858
页数:14
相关论文
共 35 条
  • [1] Off-axis re-entrant cavity ring-down spectroscopy with a mid-infrared continuous-wave optical parametric oscillator
    Peltola, J.
    Vainio, M.
    Ulvila, V.
    Siltanen, M.
    Metsala, M.
    Halonen, L.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2012, 107 (03): : 839 - 847
  • [2] Off-axis re-entrant cavity ring-down spectroscopy with a mid-infrared continuous-wave optical parametric oscillator
    J. Peltola
    M. Vainio
    V. Ulvila
    M. Siltanen
    M. Metsälä
    L. Halonen
    Applied Physics B, 2012, 107 : 839 - 847
  • [3] Diode ring-down spectroscopy without intensity modulation in an off-axis multipass cavity
    Nikolaev, I. V.
    Ochkin, V. N.
    Spiridonov, M. V.
    Tskhai, S. N.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2007, 66 (4-5) : 832 - 835
  • [4] Detection of trace gases using frequency modulated off-axis cavity ring-down spectroscopy
    Karpf, Andreas
    Rao, Gottipaty N.
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XIII, 2012, 8358
  • [5] On-axis and off-axis phase shift cavity ring down spectroscopy
    Camejo, David
    Nyaupane, Parashu
    Manzanares, Carlos E.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [6] Detection of Trace Amounts of NO2 Using Frequency Modulated Off-Axis Cavity Ring-Down Spectroscopy
    Karpf, Andreas
    Rao, Gottipaty N.
    2012 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2012,
  • [7] Off-axis cavity ring down spectroscopy at low temperatures for laboratory study of planetary atmospheres
    Manzanares, Carlos E.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [8] ANYL 187-Off-axis cavity ring-down spectroscopy: Application to investigation of nocturnal nitrogen oxide chemistry
    Simpson, William R.
    Apodaca, Randy
    Huff, Deanna
    Ayers, James D.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 232
  • [9] High-speed cavity ringdown spectroscopy with increased spectral resolution by simultaneous laser and cavity tuning
    Debecker, I
    Mohamed, AK
    Romanini, D
    OPTICS EXPRESS, 2005, 13 (08): : 2906 - 2915
  • [10] High-speed integrated semiconductor micro-ring lasers with efficient off-axis parabolic reflectors
    Verschaffelt, Guy
    Wang, Zhuoran
    Shu, Yi
    Mezosi, Gabor
    Danckaert, Jan
    Sorel, Marc
    Yu, Siyuan
    SEMICONDUCTOR LASERS AND LASER DYNAMICS III, 2008, 6997