Impact of Length and Hydrophilic Coating of the Introducer Sheath on Radial Artery Spasm During Transradial Coronary Intervention A Randomized Study

被引:153
|
作者
Rathore, Sudhir [1 ]
Stables, Rodney H. [1 ]
Pauriah, Maheshwar [1 ]
Hakeem, Abdul [1 ]
Mills, Joseph D. [1 ]
Palmer, Nick D. [1 ]
Perry, Raphael A. [1 ]
Morris, John L. [1 ]
机构
[1] Liverpool Heart & Chest Hosp, Dept Cardiol, Liverpool L14 3PE, Merseyside, England
关键词
transradial coronary procedures; radial artery spasm; randomized study; radial artery occlusion; introducer sheaths; CARDIAC-CATHETERIZATION; VASCULAR COMPLICATIONS; FEMORAL APPROACH; ALLENS TEST; ANGIOPLASTY; ANGIOGRAPHY; DISCOMFORT; PATIENT;
D O I
10.1016/j.jcin.2010.03.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The aim of this study was to assess the impact of length and hydrophilic coating of the introducer sheath on radial artery spasm, radial artery occlusion, and local vascular complications in patients undergoing transradial coronary procedures. Background Radial artery spasm is common during transradial procedures and the most common cause for procedural failure. Methods We randomly assigned, in a factorial design, 790 patients scheduled for a transradial coronary procedure to long (23-cm) or short (13-cm) and hydrophilic-coated or uncoated introducer sheaths. The primary outcome measure was clinical evidence of radial artery spasm, and secondary outcome measures were patient discomfort and local vascular complications. Results Procedural success was achieved in 96% of the cases, and radial artery spasm accounted for 17 of 33 failed cases. There was significantly less radial artery spasm (19.0% vs. 39.9%, odds ratio [OR]: 2.87; 95% confidence interval [CI]: 2.07 to 3.97, p < 0.001) and patient reported discomfort (15.1% vs. 28.5%, OR: 2.27; 95% CI: 1.59 to 3.23, p < 0.001) in patients receiving a hydrophilic-coated sheath. No difference was observed between long and short sheaths. Radial artery occlusion was observed in 9.5% of the patients and was not influenced by sheath length or coating. A local large hematoma or arterial dissection was seen in 2.6% of the patients with no difference in groups allocated at randomization. Younger age, female sex, diabetes, and lower body mass index were identified as independent predictors of radial artery spasm. Conclusions Hydrophilic sheath coating, but not sheath length, reduces the incidence of radial artery spasm during transradial coronary procedures. (J Am Coll Cardiol Intv 2010;3:475-83) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:475 / 483
页数:9
相关论文
共 50 条
  • [1] IMPACT OF LENGTH AND HYDROPHILIC COATING OF THE INTRODUCER SHEATH ON RADIAL ARTERY SPASM DURING TRANSRADIAL CORONARY INTERVENTION: A RANDOMISED STUDY
    Rathore, S.
    Stables, R. H.
    Pauriah, M.
    Hakeem, A.
    Mills, J. D.
    Palmer, N. D.
    Perry, R.
    Morris, J. L.
    HEART, 2010, 96 : A20 - A20
  • [2] IMPACT OF LENGTH AND HYDROPHILIC COATING OF THE INTRODUCER SHEATH ON RADIAL ARTERY SPASM DURING TRANSRADIAL CORONARY INTERVENTION: A RANDOMISED STUDY
    Rathore, Sudhir
    Stables, Rodney H.
    Pauriah, Maheswar
    Hakeem, Abdul
    Mills, Joseph D.
    Palmer, Nick
    Perry, Raphael A.
    Morris, John L.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [3] Usefulness of hydrophilic coating on arterial sheath introducer in transradial coronary intervention
    Saito, S
    Tanaka, S
    Hiroe, Y
    Miyashita, Y
    Takahashi, S
    Satake, S
    Tanaka, K
    Yamamoto, M
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (03) : 328 - 332
  • [4] Incidence and predictors of radial artery spasm during transradial coronary angiography and intervention
    JIA DeanZHOU YujieSHI DongmeiLIU YuyangWANG JianlongLIU XiaoliWANG Zhijian YANG ShiweiGE HailongHU BinYAN ZhenxianCHEN Yi and GAO Fei Department of CardiologyBeijing Anzhen HospitalCapital Medical UniversityBeijing China
    中华医学杂志(英文版), 2010, (07) : 843 - 847
  • [5] Incidence and predictors of radial artery spasm during transradial coronary angiography and intervention
    Jia De-an
    Zhou Yu-jie
    Shi Dong-mei
    Liu Yu-yang
    Wang Jian-long
    Liu Xiao-li
    Wang Zhi-jian
    Yang Shi-wei
    Ge Hai-long
    Hu Bin
    Yan Zhen-xian
    Chen Yi
    Gao Fei
    CHINESE MEDICAL JOURNAL, 2010, 123 (07) : 843 - 847
  • [6] Radial Artery Spasm During Transradial Coronary Procedures
    Kristic, Ivica
    Lukenda, Josip
    JOURNAL OF INVASIVE CARDIOLOGY, 2011, 23 (12): : 527 - 531
  • [7] Impact of Introducer Sheath Coating on Endothelial Function in Humans After Transradial Coronary Procedures
    Dawson, Ellen A.
    Rathore, Sudhir
    Cable, N. Timothy
    Wright, D. Jay
    Morris, John L.
    Green, Daniel J.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (02) : 148 - 156
  • [8] Use of 25cm Long Hydrophilic Radial Sheath Eliminated Clinically Significant Radial Artery Spasm During Trans-radial Coronary Intervention
    Chan, Andy Wai-Kwong
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (16) : S88 - S89
  • [9] Pericardiacophrenic Artery Perforation and Radial Artery Spasm: Dealing With Complications of Transradial Coronary Angiography and Intervention
    Roy, Sumon
    Kabach, Mohamad
    Patel, Dhaval B.
    Guzman, Luis A.
    Jovin, Ion S.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 45 : 84 - 84
  • [10] Endothelial dysfunction and the occurrence of radial artery spasm during transradial coronary procedures: the ACRA-Spasm study
    van der Heijden, Dirk J.
    van Leeuwen, Maarten A. H.
    Janssens, Gladys N.
    Hermie, Jailen
    Lenzen, Mattie J.
    Ritt, Marco J. P. F.
    van de Ven, Peter M.
    Kiemeneij, Ferdinand
    van Royen, Niels
    EUROINTERVENTION, 2016, 12 (10) : 1263 - 1270