Real-Time Cardiorespiratory Coherence is Blind to Changes in Respiration During General Anesthesia

被引:0
|
作者
Brouse, Chris J. [1 ]
Dumont, Guy A. [1 ]
Myers, Dorothy [2 ]
Cooke, Erin [2 ]
Stinson, Jonathan [2 ]
Lim, Joanne [2 ]
Ansermino, J. Mark [2 ]
机构
[1] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V5Z 1M9, Canada
[2] Univ British Columbia, Dept Anesthesiol Pharmacol & Therapeut, Vancouver, BC V5Z 1M9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
HEART-RATE-VARIABILITY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose. A novel real-time cardiorespiratory coherence (CRC) algorithm has been developed to monitor nociception during general anesthesia. CRC uses custom designed filters to track and analyze the respiratory sinus arrhythmia (RSA) as it moves in time and frequency. CRC is a form of sensor fusion between heart rate and respiration, estimating the strength of linear coupling between the two signals. The aim of this study was to estimate the effect of changes in respiration rate (RR) and peak airway pressure (PPaw) on CRC. The response of CRC was compared to a prior offline wavelet-based algorithm (WTCRC) as well as traditional univariate heart rate variability (HRV) measures. A nociception index was created for each algorithm, ranging from 0 (no nociception) to 100 (strong nociception). Methods. Following ethics approval and informed consent, data were collected from 48 children receiving general anesthesia during dental surgery. The times of change in RR and PPaw events were noted in real-time. A total of 43 RR and 35 PPaw change events were analyzed post hoc in pseudo real-time. The nociception index averages were compared between a baseline period and a response period around each event. A Wilcoxon rank-sum test was used to compare changes. Results. The change in RR changed the CRC nociception index by an average of -2.2 [95% CI from -10 to 4.7] (P > 0.3), and the change in PPaw changed the CRC nociception index by an average of 5.4 [-1.0 to 11] (P > 0.1). The changes were smaller than those of many traditional HRV measures. Conclusions. Real-time CRC was blind to the changes in respiration, and was less sensitive than many of the traditional HRV measures. A nociception index based on CRC can thus function across a wider range of respiratory conditions than can many traditional univariate HRV measures. The real-time CRC algorithm shows promise for monitoring nociception during general anesthesia.
引用
收藏
页码:5360 / 5364
页数:5
相关论文
共 50 条
  • [1] Real-Time Cardiorespiratory Coherence Detects Antinociception During General Anesthesia
    Brouse, Chris J.
    Karlen, Walter
    Dumont, Guy A.
    Myers, Dorothy
    Cooke, Erin
    Stinson, Jonathan
    Lim, Joanne
    Ansermino, J. Mark
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3813 - 3816
  • [2] Monitoring nociception during general anesthesia with cardiorespiratory coherence
    Chris J. Brouse
    Walter Karlen
    Guy A. Dumont
    Dorothy Myers
    Erin Cooke
    Jonathan Stinson
    Joanne Lim
    J. Mark Ansermino
    Journal of Clinical Monitoring and Computing, 2013, 27 : 551 - 560
  • [3] Monitoring nociception during general anesthesia with cardiorespiratory coherence
    Brouse, Chris J.
    Karlen, Walter
    Dumont, Guy A.
    Myers, Dorothy
    Cooke, Erin
    Stinson, Jonathan
    Lim, Joanne
    Ansermino, J. Mark
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2013, 27 (05) : 551 - 560
  • [4] Wavelet Transform Cardiorespiratory Coherence Detects Patient Movement During General Anesthesia
    Brouse, Christopher J.
    Karlen, Walter
    Myers, Dorothy
    Cooke, Erin
    Stinson, Jonathan
    Lim, Joanne
    Dumont, Guy A.
    Ansermino, J. Mark
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 6114 - 6117
  • [5] Real-time human respiration carbon dioxide measurement device for cardiorespiratory assessment
    Singh, Om Prakash
    Howe, Teo Aik
    Malarvili, M. B.
    JOURNAL OF BREATH RESEARCH, 2018, 12 (02)
  • [6] Real-time algorithm for changes detection in depth of anesthesia signals
    Sebastiao, Raquel
    Silva, Margarida M.
    Rabico, Rui
    Gama, Joao
    Mendonca, Teresa
    EVOLVING SYSTEMS, 2013, 4 (01) : 3 - 12
  • [7] Real-time coherence holography
    Naik, Dinesh N.
    Ezawa, Takahiro
    Miyamoto, Yoko
    Takeda, Mitsuo
    OPTICS EXPRESS, 2010, 18 (13): : 13782 - 13787
  • [8] Mass spectrometer for real-time metabolism monitoring during anesthesia
    Elizarov, A. Yu.
    Levshankov, A. I.
    TECHNICAL PHYSICS, 2012, 57 (06) : 881 - 884
  • [9] Mass spectrometer for real-time metabolism monitoring during anesthesia
    A. Yu. Elizarov
    A. I. Levshankov
    Technical Physics, 2012, 57 : 881 - 884
  • [10] Real-time Respiration Measurement during Sleep Using a Microwave Sensor
    Chen, Ying
    Kaneko, Masahiko
    Hirose, Shinichi
    Chen, Wenxi
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 3791 - 3794