Dose as a function of lung volume and planned treatment volume in helical tomotherapy intensity-modulated radiation therapy-based stereotactic body radiation therapy for small lung tumors

被引:34
|
作者
Baisden, Joseph M.
Romney, Davis A.
Reish, Andrew G.
Cai, Jing
Sheng, Ke
Jones, David R.
Benedict, Stanley H.
Read, Paul W.
Larner, James M.
机构
[1] Univ Virginia Hlth Syst, Dept Radiat Oncol, Charlottesville, VA 22908 USA
[2] Univ Virginia Hlth Syst, Dept Thorac & Cardiovasc Surg, Charlottesville, VA 22908 USA
[3] Univ Virginia, Sch Med, Charlottesville, VA 22908 USA
关键词
SBRT; NSCLC; radiosurgery; tomotherapy; lung;
D O I
10.1016/j.ijrobp.2007.03.024
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the limitations of Hi-Art Helical Tomotherapy (Middleton, WI) stereotactic body radiotherapy (SBRT) for lung lesions, and to provide an initial report on patients treated with this method. Stereotactic body radiotherapy was shown to be an effective, well-tolerated treatment for early-stage, non-small-cell lung carcinoma (NSCLC). The Radiation Therapy Oncollogy Group (RTOG) 0236 protocol is currently evaluating three-dimensional conformal SBRT that delivers 60 Gy in three fractions. Methods and Materials: Inverse treatment planning for hypothetical lung gross tumor volumes (GTV) and planned treatment volume (PTV) expansions were performed. We tested the hypothesis that the maximum acceptable dose (MAD) to be delivered to the lesion by SBRT could be predicted by PTV and lung volume. Dose constraints on normal tissue were as designated by the RTOG protocol. Inverse planning was performed to find the maximum tolerated SBRT dose up to 60 Gy. Results: Regression analysis of the data obtained indicated a linear relationship between MAD, PTV, and lung volume. This generated two equations which may be useful predictive tools. Seven patients with Stage I and II NSCLC treated at the University of Virginia with this method tolerated the treatment extremely well, and suffered no greater than grade I toxicity, with no evidence of disease recurrence in follow-up from 2-20 months. Conclusions: Helical tomotherapy SBRT for lung lesions is well-tolerated. In addition, the likely MAD for patients considered for this type of treatment can be predicted by PTV and lung volume. (C) 2007 Elsevier Inc.
引用
收藏
页码:1229 / 1237
页数:9
相关论文
共 50 条
  • [1] Dose as a function of liver volume and planning target volume in helical tomotherapy, intensity-modulated radiation therapy-based stereotactic body radiation therapy for hepatic metastasis
    Baisden, Joseph M.
    Reish, Andrew G.
    Sheng, Ke
    Larner, James M.
    Kavanagh, Brian D.
    Read, Paul W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (02): : 620 - 625
  • [2] Efficacy and Toxicities of Intensity-Modulated Stereotactic Body Radiation Therapy Using Helical Tomotherapy for Lung Cancer and Lung Metastases
    Nagai, A.
    Shibamoto, Y.
    Yoshida, M.
    Kikuchi, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S609 - S609
  • [3] Outcome of intensity-modulated radiation therapy-based stereotactic radiation therapy for treatment of canine nasal carcinomas
    Fox-Alvarez, Stacey
    Shiomitsu, Keijiro
    Lejeune, Amandine T.
    Szivek, Anna
    Kubicek, Lyndsay
    VETERINARY RADIOLOGY & ULTRASOUND, 2020, 61 (03) : 370 - 378
  • [4] The radiation techniques of tomotherapy & intensity-modulated radiation therapy applied to lung cancer
    Zhu, Zhengfei
    Fu, Xiaolong
    TRANSLATIONAL LUNG CANCER RESEARCH, 2015, 4 (03) : 265 - 274
  • [5] Comparison of spinal Stereotactic Body Radiotherapy (SBRT) planning techniques: intensity-modulated radiation therapy, modulated arc therapy, and helical tomotherapy
    Kim, Jina
    Jang, Hong Seok
    Kim, Yeon Sil
    Choi, Byung Ock
    Kang, Young-nam
    MEDICAL DOSIMETRY, 2017, 42 (03) : 210 - 215
  • [6] Dosimetric Evaluation of Compensator Intensity Modulated Radiation Therapy-based Stereotactic Body Radiation Therapy for Stage I Non-small Cell Lung Cancer
    Tajima, Y.
    Nakayama, H.
    Mikami, R.
    Nogi, S.
    Kobayashi, M.
    Okubo, M.
    Kanesaka, N.
    Sugahara, S.
    Tokuuye, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S575 - S575
  • [7] DOSE-VOLUME ANALYSIS OF RADIATION LUNG INJURY AFTER STEREOTACTIC BODY RADIATION THERAPY
    Masciullo, S.
    Masi, L.
    Casamassima, F.
    Menichelli, C.
    Bonucci, I.
    Doro, R.
    RADIOTHERAPY AND ONCOLOGY, 2011, 98 : S44 - S44
  • [8] A Monte Carlo approach to lung dose calculation in small fields used in intensity modulated radiation therapy and stereotactic body radiation therapy
    Mesbahi, Asghar
    Dadgar, Habib
    Ghareh-Aghaji, Nahideh
    Mohammadzadeh, Mohammad
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2014, 10 (04) : 896 - 902
  • [9] Adequate target volume in total-body irradiation by intensity-modulated radiation therapy using helical tomotherapy: a simulation study
    Takenaka, Ryosuke
    Haga, Akihiro
    Yamashita, Hideomi
    Nakagawa, Keiichi
    JOURNAL OF RADIATION RESEARCH, 2017, 58 (02) : 210 - 216
  • [10] Intensity-modulated radiation therapy and stereotactic body radiation therapy for head and neck tumors: Evidence-based medicine
    Lapierre, A.
    Martin, F.
    Lapeyre, M.
    CANCER RADIOTHERAPIE, 2014, 18 (5-6): : 468 - 472