共 20 条
Age-related decrease in collagen proton fraction in tibial tendons estimated by magnetization transfer modeling of ultrashort echo time magnetic resonance imaging (UTE-MRI)
被引:26
|作者:
Jerban, Saeed
[1
]
Ma, Yajun
[1
]
Namiranian, Behnam
[1
]
Ashir, Aria
[1
]
Shirazian, Hoda
[1
]
Wei, Zhao
[1
]
Le, Nicole
[2
]
Wu, Mei
[1
]
Cai, Zhenyu
[1
]
Du, Jiang
[1
]
Chang, Eric Y.
[1
,2
]
机构:
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] VA San Diego Healthcare Syst, Radiol Serv, San Diego, CA 92161 USA
关键词:
ACHILLES-TENDON;
IN-VIVO;
HEALTHY;
STRESS;
TISSUE;
WATER;
WELL;
T2;
D O I:
10.1038/s41598-019-54559-3
中图分类号:
O [数理科学和化学];
P [天文学、地球科学];
Q [生物科学];
N [自然科学总论];
学科分类号:
07 ;
0710 ;
09 ;
摘要:
Clinical magnetic resonance imaging (MRI) sequences are not often capable of directly visualizing tendons. Ultrashort echo time (UTE) MRI can acquire high signal from tendons thus enabling quantitative assessments. Magnetization transfer (MT) modeling combined with UTE-MRI-UTE-MT-modeling-can indirectly assess macromolecular protons in the tendon. This study aimed to determine if UTE-MT-modeling is a quantitative technique sensitive to the age-related changes of tendons. The legs of 26 young healthy (29 +/- 6 years old) and 22 elderly (75 +/- 8 years old) female subjects were imaged using UTE sequences on a 3T MRI scanner. Institutional review board approval was obtained, and all recruited subjects provided written informed consent. T1 and UTE-MT-modeling were performed on anterior tibialis tendons (ATT) and posterior tibialis tendons (PTT) as two representative human leg tendons. A series of MT pulse saturation powers (500-1500 degrees) and frequency offsets (2-50 kHz) were used to measure the macromolecular fraction (MMF) and macromolecular T2 (T2(MM)). All measurements were repeated by three independent readers for a reproducibility study. MMF demonstrated significantly lower values on average in the elderly cohort compared with the younger cohort for both ATT (decreased by 16.8%, p = 0.03) and PTT (decreased by 23.0%, p < 0.01). T2(MM) and T1 did not show a significant nor a consistent difference between the young and elderly cohorts. For all MRI parameters, intraclass correlation coefficient (ICC) was higher than 0.98, indicating excellent consistency between measurements performed by independent readers. MMF serving as a surrogate measure for collagen content, showed a significant decrease in elderly leg tendons. This study highlighted UTE-MRI-MT techniques as a useful quantitative method to assess the impact of aging on human tendons.
引用
收藏
页数:7
相关论文