Age-related decrease in collagen proton fraction in tibial tendons estimated by magnetization transfer modeling of ultrashort echo time magnetic resonance imaging (UTE-MRI)

被引:26
|
作者
Jerban, Saeed [1 ]
Ma, Yajun [1 ]
Namiranian, Behnam [1 ]
Ashir, Aria [1 ]
Shirazian, Hoda [1 ]
Wei, Zhao [1 ]
Le, Nicole [2 ]
Wu, Mei [1 ]
Cai, Zhenyu [1 ]
Du, Jiang [1 ]
Chang, Eric Y. [1 ,2 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] VA San Diego Healthcare Syst, Radiol Serv, San Diego, CA 92161 USA
关键词
ACHILLES-TENDON; IN-VIVO; HEALTHY; STRESS; TISSUE; WATER; WELL; T2;
D O I
10.1038/s41598-019-54559-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Clinical magnetic resonance imaging (MRI) sequences are not often capable of directly visualizing tendons. Ultrashort echo time (UTE) MRI can acquire high signal from tendons thus enabling quantitative assessments. Magnetization transfer (MT) modeling combined with UTE-MRI-UTE-MT-modeling-can indirectly assess macromolecular protons in the tendon. This study aimed to determine if UTE-MT-modeling is a quantitative technique sensitive to the age-related changes of tendons. The legs of 26 young healthy (29 +/- 6 years old) and 22 elderly (75 +/- 8 years old) female subjects were imaged using UTE sequences on a 3T MRI scanner. Institutional review board approval was obtained, and all recruited subjects provided written informed consent. T1 and UTE-MT-modeling were performed on anterior tibialis tendons (ATT) and posterior tibialis tendons (PTT) as two representative human leg tendons. A series of MT pulse saturation powers (500-1500 degrees) and frequency offsets (2-50 kHz) were used to measure the macromolecular fraction (MMF) and macromolecular T2 (T2(MM)). All measurements were repeated by three independent readers for a reproducibility study. MMF demonstrated significantly lower values on average in the elderly cohort compared with the younger cohort for both ATT (decreased by 16.8%, p = 0.03) and PTT (decreased by 23.0%, p < 0.01). T2(MM) and T1 did not show a significant nor a consistent difference between the young and elderly cohorts. For all MRI parameters, intraclass correlation coefficient (ICC) was higher than 0.98, indicating excellent consistency between measurements performed by independent readers. MMF serving as a surrogate measure for collagen content, showed a significant decrease in elderly leg tendons. This study highlighted UTE-MRI-MT techniques as a useful quantitative method to assess the impact of aging on human tendons.
引用
收藏
页数:7
相关论文
共 20 条
  • [1] Age-related decrease in collagen proton fraction in tibial tendons estimated by magnetization transfer modeling of ultrashort echo time magnetic resonance imaging (UTE-MRI)
    Saeed Jerban
    Yajun Ma
    Behnam Namiranian
    Aria Ashir
    Hoda Shirazian
    Zhao Wei
    Nicole Le
    Mei Wu
    Zhenyu Cai
    Jiang Du
    Eric Y. Chang
    Scientific Reports, 9
  • [2] Achilles tendon and enthesis assessment using ultrashort echo time magnetic resonance imaging (UTE-MRI) T1 and magnetization transfer (MT) modeling in psoriatic arthritis
    Moazamian, Dina
    Athertya, Jiyo S.
    Dwek, Sophia
    Lombardi, Alecio F.
    Mohammadi, Hamidreza Shaterian
    Sedaghat, Sam
    Jang, Hyungseok
    Ma, Yajun
    Chung, Christine B.
    Du, Jiang
    Jerban, Saeed
    Chang, Eric Y.
    NMR IN BIOMEDICINE, 2024, 37 (01)
  • [3] Assessing cortical bone mechanical properties using collagen proton fraction from ultrashort echo time magnetization transfer (UTE-MT) MRI modeling
    Jerban, Saeed
    Ma, Yajun
    Dorthe, Erik W.
    Kakos, Lena
    Le, Nicole
    Alenezi, Salem
    Sah, Robert L.
    Chang, Eric Y.
    D'Lima, Darryl
    Du, Jiang
    BONE REPORTS, 2019, 11
  • [4] Ultrashort echo time magnetic resonance imaging (UTE-MRI) of cortical bone correlates well with histomorphometric assessment of bone microstructure
    Jerban, Saeed
    Ma, Yajun
    Wong, Jonathan H.
    Nazaran, Amin
    Searleman, Adam
    Wan, Lidi
    Williams, Judith
    Du, Jiang
    Chang, Eric Y.
    BONE, 2019, 123 : 8 - 17
  • [5] Collagen proton fraction from ultrashort echo time magnetization transfer (UTE-MT) MRI modelling correlates significantly with cortical bone porosity measured with micro-computed tomography (μCT)
    Jerban, Saeed
    Ma, Yajun
    Wan, Lidi
    Searleman, Adam C.
    Jang, Hyungseok
    Sah, Robert L.
    Chang, Eric Y.
    Du, Jiang
    NMR IN BIOMEDICINE, 2019, 32 (02)
  • [6] Magnetic resonance imaging (MRI) of articular cartilage of the knee using ultrashort echo time (uTE) sequences with spiral acquisition
    Goto, Hajimu
    Fujii, Masahiko
    Iwama, Yuki
    Aoyama, Nobukazu
    Ohno, Yoshiharu
    Sugimura, Kazuro
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (03) : 318 - 323
  • [7] Ultrashort echo time magnetization transfer (UTE-MT) imaging and modeling: magic angle independent biomarkers of tissue properties
    Ma, Ya-Jun
    Shao, Hongda
    Du, Jiang
    Chang, Eric Y.
    NMR IN BIOMEDICINE, 2016, 29 (11) : 1546 - 1552
  • [8] Three-dimensional ultrashort echo time cones (3D UTE-Cones) magnetic resonance imaging of entheses and tendons
    Chen, Bimin
    Zhao, Yinghua
    Cheng, Xin
    Ma, Yajun
    Chang, Eric Y.
    Kavanaugh, Arthur
    Liu, Sirun
    Du, Jiang
    MAGNETIC RESONANCE IMAGING, 2018, 49 : 4 - 9
  • [9] Study of bubble dynamics in gas-solid fluidized beds using ultrashort echo time (UTE) magnetic resonance imaging (MRI)
    Fabich, Hilary T.
    Sederman, Andrew J.
    Holland, Daniel J.
    CHEMICAL ENGINEERING SCIENCE, 2017, 172 : 476 - 486
  • [10] Robust Assessment of Macromolecular Fraction (MMF) in Muscle with Differing Fat Fraction Using Ultrashort Echo Time (UTE) Magnetization Transfer Modeling with Measured T1
    Jerban, Saeed
    Ma, Yajun
    Tang, Qingbo
    Fu, Eddie
    Szeverenyi, Nikolaus
    Jang, Hyungseok
    Chung, Christine B. B.
    Du, Jiang
    Chang, Eric Y. Y.
    DIAGNOSTICS, 2023, 13 (05)