Copper Nanoparticles/Poly Acrylic Acid/Reduced Graphene Oxide Nanocomposite Modified Glassy Carbon Electrode for Determination of 4-Nitrophenol in Water

被引:3
|
作者
Zhang Cui-Zhong [1 ,2 ]
Zhang Zhen-Fa [1 ,2 ]
Lian Huan [1 ,2 ]
Liang Cai-Yun [1 ,2 ]
Li Kai [1 ]
Peng Jin-Yun [1 ,2 ]
机构
[1] Guangxi Normal Univ Nationalities, Chongzuo 532200, Peoples R China
[2] Guangxi Coll & Univ Key Lab Breeding Base Chem Gu, Chongzuo 532200, Peoples R China
基金
中国国家自然科学基金;
关键词
Graphene; 4-Nitrophenol; Copper nanoparticles; Chronoamperometry; Chronocoulometry; Differential pulse voltammetry; ELECTROCHEMICAL SENSOR; HIGH-PERFORMANCE; REDUCTION; HYDROQUINONE; COMPOSITE; DOPAMINE; NITROPHENOL; ADSORPTION; CATALYSTS; CATECHOL;
D O I
10.11895/j.issn.0253-3820.160606
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A moderate and simple in situ growth approach was employed to load copper nanoparticles (CuNPs) noncovalently on graphene for preparation of CuNPs/poly acrylic acid/reduced graphene oxide (CuNPs/PAA/GR) nanocomposites for electro-catalysis of 4-nitrophenol (4-NP). The morphology of the material was observed by scanning electron microscopy (SEM). Tests with various scan rates and pH conditions indicated an adsorption-controlled electrode process occurred. The mechanism of the electrode reaction of 4-NP involved a two-electron process accompanied by a deprotonation step. Electrochemical parameters were calculated with the electron transfer number (n) as 2. 3, the effective area (0. 6275 cm(2)) of CuNPs/PAA/GR/GCE electrode was 2. 22 times as large as that of bare electrode, the adsorption capacity. Gamma(s) value was 1. 6x10(-11) mol/cm(2), and the average value of the calculated k(cat) value was 1. 15x10(4) L/(mol.s). Under the optimal conditions, the differential pulse voltammetric response of the electrode showed a linear relationship with 4-NP concentration in the range of 1-150 mmol/L. The regression equation was I-pa(mu A)= -0. 015C (mu mol/L)-0. 98 (R-2 = 0. 9951), and the detection limit was 0. 23 mu mol/L (S/N = 3). The fabricated sensor exhibited high sensitivity, good stability and high reproducibility. This sensor was applied for detection of 4-NP in water samples with favorable recoveries of 88. 6% - 100. 7% and relative standard deviation (RSD) of 2. 6% -5. 9%.
引用
收藏
页码:28 / 34
页数:7
相关论文
共 37 条
  • [1] ANDRIEUX CP, 1978, J ELECTROANAL CHEM, V93, P163, DOI 10.1016/S0022-0728(78)80230-7
  • [2] [Anonymous], ELECTROCHIM ACTA
  • [3] [Anonymous], ENV MONITORING CHINA
  • [4] [Anonymous], J FUNCTIONAL MAT
  • [5] [Anonymous], ENV MONITORING CHINA
  • [6] [Anonymous], J FUNCTIONAL MAT
  • [7] [Anonymous], J NW NORMAL U NATURA
  • [9] PHENOLICS IN AQUATIC ECOSYSTEMS - SELECTED REVIEW OF RECENT LITERATURE
    BUIKEMA, AL
    MCGINNISS, MJ
    CAIRNS, J
    [J]. MARINE ENVIRONMENTAL RESEARCH, 1979, 2 (02) : 87 - 181
  • [10] Self-Assembled Free-Standing Graphite Oxide Membrane
    Chen, Chengmeng
    Yang, Quan-Hong
    Yang, Yonggang
    Lv, Wei
    Wen, Yuefang
    Hou, Peng-Xiang
    Wang, Maozhang
    Cheng, Hui-Ming
    [J]. ADVANCED MATERIALS, 2009, 21 (29) : 3007 - 3011