Comparison of test performance of biochemical parameters in semiautomatic method and fully automatic analyzer method

被引:4
|
作者
Kumari, Suchitra [1 ]
Bahinipati, Jyotirmayee [2 ]
Pradhan, Tapaswini [2 ]
Sahoo, Durgesh P. [3 ]
机构
[1] All India Inst Med Sci AIIMS, Dept Biochem, Bhubaneswar, Odisha, India
[2] Kalinga Inst Med Sci KIMS, Dept Biochem, Bhubaneswar 751024, Odisha, India
[3] All India Inst Med Sci AIIMS, Dept CMFM, Bhubaneswar, Odisha, India
关键词
Auto analyzer; biochemical parameters; performance standard; semiauto analyzer; QUALITY;
D O I
10.4103/jfmpc.jfmpc_94_20
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The primary health-care center (PHC) and community health center (CHC) are not well equipped with laboratory services. Semiauto analyzer-based reporting could be an effective modality, provided that the performance standard is comparable to that of the fully automatic analyzer. So, the objective of this study was to analyze the test results of biochemical parameters in semiauto and fully automatic analyzer and to compare the quality performance. Materials and Methods: One hundred forty-nine patients undergoing routine biochemical investigations in the department laboratory were enrolled in this study. Two millimeter of venous blood was collected from all the participants and processed for urea, cholesterol, triglyceride (TG), serum glutamate-oxaloacetate transaminase (SGOT) (aspartate aminotransferase), and serum glutamate-pyruvate transaminase (SGPT) (alanine aminotransferase) by using standard kits (ERBA) in semiauto analyzer (Transasia Erba Chem5X by Calbiotech Inc. USA, semiautomated clinical chemistry analyzer) and the fully automatic analyzer (Cobas Integra 400 Roche, Germany) method. Results: There was high variability in the distribution of urea, TG, SGOT, and SGPT values in both measurement methods, whereas cholesterol data followed a normal distribution (skewness: 1.522, 1.037; kurtosis: 2.373, 0.693 in semiauto and automated methods, respectively). A significant positive correlation between both the methods of assessment was observed in urea, cholesterol, TGs, SGOT, and SGPT. The mean difference for urea was -9.85 +/- 23.997 (LOA: 37.189, -56.88), whereas it was highest for TG -24.34 +/- 38.513 (LOA: 51.144, -99.829), suggesting that both methods can measure urea with less difference in absolute values, whereas for TG the measurement values are highly variable. Conclusion: The test performance of biochemical parameters such as urea, total cholesterol, TGs, SGOT, and SGPT taken by semiauto analyzer and fully automatic analyzer method of assessment were highly related and comparable.
引用
收藏
页码:3994 / 4000
页数:7
相关论文
共 50 条
  • [1] A Fully Automatic Geometric Parameters Determining Method for Electron Tomography
    Chen, Yu
    Wang, Zihao
    Li, Lun
    Wan, Xiaohua
    Sun, Fei
    Zhang, Fa
    BIOINFORMATICS RESEARCH AND APPLICATIONS (ISBRA 2017), 2017, 10330 : 385 - 389
  • [2] SEMIAUTOMATIC METHOD OF DETERMINING CALCIUM IN A TEST HYDROLYSATE
    ARNETH, W
    FLEISCHWIRTSCHAFT, 1977, 57 (01): : 100 - 102
  • [3] VALIDATION STUDY OF SOME BIOCHEMICAL PARAMETERS USING AN AUTOMATIC ANALYZER
    Popescu, Anisoara
    Orasanu, Adriana
    REVISTA ROMANA DE MEDICINA VETERINARA, 2012, 22 (01): : 48 - 56
  • [4] A new method for automatic performance comparison of search engines
    Li L.
    Shang Y.
    World Wide Web, 2000, 3 (04) : 241 - 247
  • [5] Comparison of bilinear process method and group test method for performance degradation
    Wang, Zhi-Hua
    Fu, Hui-Min
    Huang, Rong
    Zhang, Yong-Bo
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2014, 29 (07): : 1562 - 1566
  • [6] Albuminuria Is Affected by Urinary Tract Infection: A Comparison between Biochemical Quantitative Method and Automatic Urine Chemistry Analyzer UC-3500
    Chou, Yi-Ju
    Yang, Chun-Chun
    Chang, Shang-Jen
    Yang, Stephen Shei-Dei
    DIAGNOSTICS, 2023, 13 (21)
  • [7] Comparison of LSRB in children measured by the Westergren method and by the Test-1 analyzer
    Papakonstantinou, E.
    Yfantis, E.
    Georgoutsou, P.
    Lavda, A.
    Skourbouti, A.
    Chaniotaki, S.
    Chontrothanasi, A.
    Koutoulas, G.
    Manti, Ch.
    ARCHIVES OF HELLENIC MEDICINE, 2010, 27 (01): : 72 - 77
  • [8] SEMIAUTOMATIC METHOD FOR BIOCHEMICAL SPECTROPHOTOMETRIC ANALYSIS DATA-PROCESSING AND PRINTING
    FESLER, R
    CLERBAUX, T
    MEDICAL LABORATORY TECHNOLOGY, 1973, 30 (04): : 341 - 345
  • [9] Research on fully automatic camera calibration method
    Xu, Yong
    Guo, Pengyu
    Long, Gucan
    Zhang, Xiaohu
    Yu, Qifeng
    Guangxue Xuebao/Acta Optica Sinica, 2013, 33 (06):
  • [10] AN AUTOMATIC METHOD FOR THROMBOTEST ON THE COBAS BIO CENTRIFUGAL ANALYZER
    KARLSEN, RL
    VISDAL, A
    STENSBERG, A
    THROMBOSIS AND HAEMOSTASIS, 1983, 50 (01) : 472 - 472