Least-squares fitting algorithm for peak pile-up correction in gamma-ray spectroscopy

被引:4
|
作者
Adrich, P. [1 ]
Zychor, I. [1 ]
机构
[1] Narodowe Ctr Badan Jadrowych, Ul Andrzeja Soltana 7, PL-05400 Otwock, Swierk, Poland
关键词
Pulse pile-up; Least-squares fitting algorithm; Gamma-ray spectroscopy; PULSE PILE; EVENT;
D O I
10.1016/j.nima.2020.164962
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In gamma-ray spectroscopy, a pulse pile-up occurs when a gamma-ray hits the detector within a time period shorter than the duration of the pulse induced by a preceding gamma-ray. The resulting pulse is the sum of two overlapping pulses. At a high counting rate, the pulse pile-up can lead to significant loss of data and/or deterioration of the measured gamma-ray energy spectrum. If the temporal separation of consecutive gamma-ray events is small enough, the resulting pile-up pulse exhibits only a single peak. Such events are described as peak pile-ups. It is not trivial to detect and correct peak pile-ups. Consequently, such events are typically wrongly reconstructed as a single pulse or rejected by the pile-up correction algorithms developed to date. We study a least-squares fitting algorithm modified to include detection and correction of peak pileups. Performance of the proposed algorithm is studied using data measured with LaBr3:Ce scintillator and a 400 MBq 137Cs source as well as with artificially synthesized pile-up data. The pile-up correction success rate grows rapidly with the temporal separation of piled-up pulses and reaches 50% as soon as the pulses are separated by a time at least of the order of the single pulse rise time. A success rate exceeding 90% is reached for the temporal separation equal to about twice the rise time. The reconstruction efficiency measured as the overall rate of the successful reconstruction of the double-pulse pile-up is about 92%.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Pile-up correction algorithm for high count rate gamma ray spectroscopy
    Hammad, M. E.
    Kasban, H.
    Fikry, R. M.
    Dessoky, Moawad, I
    Zahran, O.
    Elaraby, Sayed M. S.
    Abd El-Samie, Fathi E.
    APPLIED RADIATION AND ISOTOPES, 2019, 151 : 196 - 206
  • [2] LEAST-SQUARES SPECTRUM FITTING METHOD FOR THE MEASUREMENT OF GE(LI) GAMMA-RAY PEAK AREAS
    GILMORE, GR
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1979, 48 (1-2): : 91 - 104
  • [3] Pile-up Recovery in Gamma-ray Detection
    Vencelj, Matjaz
    Likar, Andrej
    Loeher, Bastian
    Miklavec, Mojca
    Novak, Roman
    Pietralla, Norbert
    Savran, Deniz
    LIGHT AT EXTREME INTENSITIES 2011, 2012, 1462 : 218 - 221
  • [4] A library least-squares approach for scatter correction in gamma-ray tomography
    Meric, Ilker
    Johansen, Geir Anton
    Malta Moreira, Icaro Valgueiro
    RADIATION PHYSICS AND CHEMISTRY, 2015, 108 : 39 - 47
  • [5] TIME-DEPENDENT DEADTIME AND PILE-UP CORRECTIONS FOR GAMMA-RAY SPECTROSCOPY
    ROSCOE, BA
    FURR, AK
    NUCLEAR INSTRUMENTS & METHODS, 1977, 140 (02): : 401 - 404
  • [6] Least-squares fitting of gamma-ray spectra with B-spline basis functions
    Zhu, M. H.
    Liu, L. G.
    You, Z.
    Xu, A. A.
    CISP 2008: FIRST INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, VOL 1, PROCEEDINGS, 2008, : 691 - +
  • [7] Pile-up Reconstruction Algorithm for High Count Rate Gamma-Ray Spectrometry
    Petrovic, T.
    Vencelj, M.
    Lipoglavsek, M.
    Novak, R.
    Savran, D.
    INTERNATIONAL CONFERENCE ON RECENT TRENDS IN NUCLEAR PHYSICS-2012 (ICRTNP-2012), 2013, 1524 : 279 - 282
  • [8] Degenerate Pile-up Correction in Pulse Height Spectra from Gamma-ray Spectrometers
    Marcer, Giulia
    Dal Molin, Andrea
    Rebai, Marica
    Rigamonti, Davide
    Tardocchi, Marco
    JOURNAL OF FUSION ENERGY, 2024, 43 (01)
  • [9] Pile-Up Correction for Inelastic Gamma-Ray Detection in Pulsed Fast Neutron Analysis
    Bae, Junwoo
    Graham, Colton
    Clarke, Shaun
    Pozzi, Sara
    Jovanovic, Igor
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2024, 71 (07) : 1420 - 1428
  • [10] PILE-UP REJECTION LIVE-TIME CORRECTION UNIT FOR PRECISION GAMMA-RAY SPECTROMETRY
    ANDAI, A