Comparison of vessel diameters in electron beam tomography and quantitative coronary angiography

被引:26
作者
Achenbach, S [1 ]
Moshage, W [1 ]
Ropers, D [1 ]
Bachmann, K [1 ]
机构
[1] Univ Erlangen Nurnberg, Med Klin 2, D-91054 Erlangen, Germany
来源
INTERNATIONAL JOURNAL OF CARDIAC IMAGING | 1998年 / 14卷 / 01期
关键词
electron beam tomography; cine CT; coronary angiography; coronary artery diameter;
D O I
10.1023/A:1005814117755
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Electron beam tomography (EBT) has been shown to permit non-invasive imaging of the coronary arteries after intravenous injection of contrast agent and 3-dimensional reconstruction. We compared the vessel diameters in EBT reconstructions to quantitative coronary angiography(QCA). 10 patients were investigated by EBT and QCA. 3-dimensional EBT reconstructions (shaded surface display) were performed after acquisition of 40 axial cross-sections of the heart with 3 mm slice thickness (1 mm overlap) which were obtained triggered to the ECG in breathhold following intravenous injection of 120-160 mi of contrast agent. A fixed lower reconstruction threshold of 80 HU was used to selectively visualize the contrast-enhanced coronary artery lumen. At 60 sites in the coronary artery system, the vessel diameters measured in the EBT reconstructions were compared to the diameters found in quantitative analysis of the patients' coronary angiograms. The correlation coefficient of the vessel diameters in EBT and QCA was 0.83. Mean vessel diameters were not significantly different in EBT and QCA (3.06+/-0.93 vs. 2.97+/-0.94 mm). However, very small vessel diameters tended to be underestimated in the EBT reconstructions, which was due to the partial volume effect. If only vessel diameters measured in the left main or left anterior descending coronary artery were compared to QCA, the correlation increased to 0.87, since these vessel segments are less prone to artifacts in the EBT investigation. Vessel diameters in EBT and QCA correlate reasonably well. Due to partial volume effects, the diameter of very small vessels and stenotic segments tends to be underestimated by EBT.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 9 条
[1]  
Achenbach S, 1996, HERZ, V21, P106
[2]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[3]   PROPOSED DYNAMIC CARDIAC 3-D DENSITOMETER FOR EARLY DETECTION AND EVALUATION OF HEART-DISEASE [J].
BOYD, DP ;
GOULD, RG ;
QUINN, JR ;
SPARKS, R ;
STANLEY, JH ;
HERRMANNSFELDT, WB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) :2724-2726
[4]   CORONARY-ARTERY CALCIFICATION DETECTED WITH ULTRAFAST CT AS AN INDICATION OF CORONARY-ARTERY DISEASE - WORK IN PROGRESS [J].
BREEN, JF ;
SHEEDY, PF ;
SCHWARTZ, RS ;
STANSON, AW ;
KAUFMANN, RB ;
MOLL, PP ;
RUMBERGER, JA .
RADIOLOGY, 1992, 185 (02) :435-439
[5]  
GOULD RG, 1992, ULTRAFAST COMPUTED T, P1
[6]   THRESHOLD SELECTION FOR CT ANGIOGRAPHY SHADED SURFACE DISPLAY OF THE RENAL-ARTERIES [J].
HALPERN, EJ ;
WECHSLER, RJ ;
DICAMPLI, D .
JOURNAL OF DIGITAL IMAGING, 1995, 8 (03) :142-147
[7]  
JUDKINS MP, 1962, MED CONCEPTS CARDIOV, V31, P735
[8]   CORONARY-ARTERY STENOSES - 3-DIMENSIONAL IMAGING WITH ELECTROCARDIOGRAPHICALLY TRIGGERED, CONTRAST AGENT-ENHANCED, ELECTRON-BEAM CT [J].
MOSHAGE, WEL ;
ACHENBACH, S ;
SEESE, B ;
BACHMANN, K ;
KIRCHGEORG, M .
RADIOLOGY, 1995, 196 (03) :707-714
[9]  
STANFORD W, 1991, American Journal of Cardiac Imaging, V5, P21