Birefringence characterization of biological tissue by use of optical coherence tomography

被引:247
|
作者
Everett, MJ [1 ]
Schoenenberger, K [1 ]
Colston, BW [1 ]
Da Silva, LB [1 ]
机构
[1] Univ Calif Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
关键词
D O I
10.1364/OL.23.000228
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An improved polarization-sensitive optical coherence tomography (OCT) system is developed and used to measure birefringence in porcine myocardium tissue and produce two-dimensional birefringence mapping of the tissue. Signal-to-noise issues that cause systematic measurement errors are analyzed to determine the regime in which such measurements are accurate. The advantage of polarization-sensitive OCT systems over standard OCT systems in avoiding image artifacts caused by birefringence is also demonstrated. (C) 1998 Optical Society of America.
引用
收藏
页码:228 / 230
页数:3
相关论文
共 50 条
  • [1] Birefringence characterization of biological tissue using optical coherence tomography
    Everett, MJ
    Schoenenberger, K
    Colston, BW
    Da Silva, LB
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS II, PROCEEDINGS OF, 1998, 3251 : 184 - 191
  • [2] Tissue birefringence characterization by use of fiber-based polarization-sensitive optical coherence tomography
    Ding, ZH
    Wu, L
    Huang, LN
    Chen, YH
    Chen, ZP
    BIOMOLECULAR PHOTONICS AND MULTIDIMENSIONAL MICROSCOPY, 2003, 5255 : 60 - 63
  • [3] Birefringence imaging of biological tissue by spectral domain polarization sensitive optical coherence tomography
    Jing, Zhijun
    Fan, Chuanmao
    Jiang, Jingying
    Gong, Qiang
    Ma, Zhenhe
    Zhang, Fan
    Yao, Jianquan
    Wang, R. K.
    OPTICS IN TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2007, 6439
  • [4] Mapping of birefringence and thermal damage in tissue by use of polarization-sensitive optical coherence tomography
    Schoenenberger, K
    Colston, BW
    Maitland, DJ
    Da Silva, LB
    Everett, MJ
    APPLIED OPTICS, 1998, 37 (25) : 6026 - 6036
  • [5] Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography
    deBoer, JF
    Milner, TE
    vanGemert, MJC
    Nelson, JS
    OPTICS LETTERS, 1997, 22 (12) : 934 - 936
  • [6] Two-dimensional birefringence imaging in biological tissue using polarization sensitive optical coherence tomography
    de Boer, JF
    Milner, TE
    van Gemert, MJC
    Nelson, JS
    OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING III, PROCEEDINGS OF, 1998, 3196 : 32 - 37
  • [7] Use of optical coherence tomography to monitor biological tissue freezing during cryosurgery
    Choi, B
    Milner, TE
    Kim, JH
    Goodman, JN
    Vargas, G
    Aguilar, G
    Nelson, JS
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (02) : 282 - 286
  • [8] Tissue characterization, with optical coherence tomography (OCT)
    Knuttel, A
    Koch, S
    Schork, R
    Bocker, D
    BIOMEDICAL SENSING, IMAGING, AND TRACKING TECHNOLOGIES I, 1996, 2676 : 54 - 64
  • [9] Tissue characterization with optical coherence tomography (OCT)
    Knuttel, A
    Breit, M
    Bocker, D
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS, PROCEEDINGS OF, 1997, 2981 : 7 - 18
  • [10] Quantification of polarization in biological tissue by optical coherence tomography
    Jiao, SL
    Wang, LV
    LASER TISSUE INTERACTION XIII: PHOTOCHEMICAL, PHOTOTHERMAL, AND PHOTOMECHANICAL, 2002, 4617 : 200 - 203