摘要
Recent events highlight the increased risk of a terrorist attack using either a nuclear or a radiological weapon. One of the key needs to counter such a threat is long-range detection of nuclear material. Theoretically, gamma-ray emissions from such material should allow passive detection to distances greater than 100 m. However, detection at this range has long been thought impractical due to spatially fluctuating levels of natural background radiation. These fluctuations are the major source of uncertainty in detection and mean that sensitivity cannot be increased simply by increasing detector size. Recent work has shown that this problem can be overcome through the use of imaging techniques. In this paper we describe the background problems, the advantages of imaging and the construction of a prototype, large-area (0.57 m(2)) gamma-ray imager to detect nuclear materials at distances of similar to100 m.
引用
收藏
页码:2238 / 2244
页数:7
相关论文
共 50 条
  • [1] Large area Imaging detector for long-range, passive detection of fissile material
    Ziock, KP
    Craig, WW
    Fabris, L
    Lanza, RC
    Gallagher, S
    Horn, BKP
    Madden, NW
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1001 - 1005
  • [2] Unobtrusive long-range detection of passive RFID tag motion
    Jiang, B
    Fishkin, KP
    Roy, S
    Philipose, M
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2006, 55 (01) : 187 - 196
  • [3] Long-Range Imaging
    LeMaster, Daniel
    Hart, Michael
    Lambert, Andrew
    Gladysz, Szymon
    OPTICAL ENGINEERING, 2017, 56 (07)
  • [4] LONG-RANGE ALPHA-DETECTOR
    MACARTHUR, DW
    ALLANDER, KS
    BOUNDS, JA
    BUTTERFIELD, KB
    MCATEE, JL
    HEALTH PHYSICS, 1992, 63 (03): : 324 - 330
  • [5] Autonomous long-range open area fire detection and reporting
    Engelhaupt, D
    Reardon, P
    Blackwell, L
    Warden, L
    Ramsey, B
    Thermosense XXVII, 2005, 5782 : 164 - 175
  • [6] Single-photon detection for long-range imaging and sensing
    Hadfield, Robert H.
    Leach, Jonathan
    Fleming, Fiona
    Paul, Douglas J.
    Tan, Chee Hing
    Ng, Jo Shien
    Henderson, Robert K.
    Buller, Gerald S.
    OPTICA, 2023, 10 (09) : 1124 - 1141
  • [7] Ultra Long-Range Interactions between Large Area Graphene and Silicon
    Na, Seung Ryul
    Suk, Ji Won
    Ruoff, Rodney S.
    Huang, Rui
    Liechti, Kenneth M.
    ACS NANO, 2014, 8 (11) : 11234 - 11242
  • [8] LONG-RANGE ALPHA-PARTICLE DETECTION IN A CELLULOSE NITRATE TRACK DETECTOR
    SHARMA, SCL
    MEHTA, GK
    NUCLEAR INSTRUMENTS & METHODS, 1980, 178 (01): : 217 - 219
  • [9] A Long-Range Mutual Gaze Detector for HRI
    Arreghini, Simone
    Abbate, Gabriele
    Giusti, Alessandro
    Paolillo, Antonio
    PROCEEDINGS OF THE 2024 ACM/IEEE INTERNATIONAL CONFERENCE ON HUMAN-ROBOT INTERACTION, HRI 2024, 2024, : 870 - 874
  • [10] Long-range alpha detection
    Kasper, K
    HEALTH PHYSICS, 1998, 75 (06): : 572 - 573