Acute effects of combined high-frequency oscillation and tracheal gas insufflation in severe acute respiratory distress syndrome

被引:29
|
作者
Mentzelopoulos, Spyros D. [1 ]
Roussos, Charis [1 ]
Koutsoukou, Antonia [1 ]
Sourlas, Sotiris [1 ]
Malachias, Sotiris [1 ]
Lachana, Alexandra [1 ]
Zakynthinos, Spyros G. [1 ]
机构
[1] Univ Athens, Sch Med, Dept Crit Care 1, Athens, Greece
关键词
respiratory distress syndrome; adult; high-frequency ventilation;
D O I
10.1097/01.CCM.0000265738.80832.BE
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. In acute respiratory distress syndrome (ARDS), high-frequency oscillation (HFO) improves oxygenation relative to conventional mechanical ventilation (CMV). Alveolar ventilation is improved by adding tracheal gas insufflation (TGI) to CMV. We hypothesized that combined HFO and TGI (HFO-TGI) might result in improved gas exchange relative to both standard HFO and CMV according to the ARDS Network protocol. Design: Prospective, randomized, crossover study, Setting. A 30-bed university intensive care unit. Patients: A total of 14 patients with early (< 72 hrs in duration), severe (PaO2/FIO2 of < 150 mm Hg and prerecruitment oxygenation index of 22.8 +/- 1.9 [mean +/- SEM]), primary ARDS. Interventions. Patients were ventilated with HFO without (60 mins) and combined with TGI (6.1 +/- 0.1 L/min, 60 mins) in random order. HFO sessions were repeated in inverse order within 24 hrs. HFO sessions were preceded and followed by ARDS Network CMV. Four recruitment maneuvers were performed during the study period. During HFO sessions, mean airway pressure was set at 1 cm H2O above the point of maximal curvature of the respiratory system expiratory pressure-volume curve. Measurements and Main Results: Gas exchange and hemodynamics were determined before, during, and after HFO sessions. HFO-TGI improved PaO2/FIO2 relative to HFO and CMV (174.5 +/- 10.4 vs. 136.0 +/- 10.0 and 105.0 +/- 3.7 mm Hg, respectively, p < .05 for both) and oxygenation index relative to HFO (17.1 +/- 1.3 vs. 22.3 +/- 1.7, respectively p < .05). PaO2/FIO2 returned to baseline within 3 hrs after HFO. During HFO-TGI, shunt fraction and mixed venous oxygen saturation improved relative to CMV (0.36 +/- 0.01 vs. 0.45 +/- 0.01 and 77.8% +/- 1.2% vs. 71.8% +/- 1.30/6, respectively, p < .05 for both). PaCO2 and hemodynamics were unaffected by HFO sessions. Respiratory mechanics remained unchanged throughout the study period. Conclusions. In early onset, primary, severe ARDS, short-term HFO-TGI improves oxygenation relative to standard HFO and ARDS Network CMV.
引用
收藏
页码:1500 / 1508
页数:9
相关论文
共 50 条
  • [1] Intermittent recruitment with high-frequency oscillation/tracheal gas insufflation in acute respiratory distress syndrome
    Mentzelopoulos, S. D.
    Malachias, S.
    Zintzaras, E.
    Kokkoris, S.
    Zakynthinos, E.
    Makris, D.
    Magira, E.
    Markaki, V.
    Roussos, C.
    Zakynthinos, S. G.
    EUROPEAN RESPIRATORY JOURNAL, 2012, 39 (03) : 635 - 647
  • [2] High-frequency oscillation and tracheal gas insufflation in patients with severe acute respiratory distress syndrome and traumatic brain injury: an interventional physiological study
    Charikleia S Vrettou
    Spyros G Zakynthinos
    Sotirios Malachias
    Spyros D Mentzelopoulos
    Critical Care, 17
  • [3] High-frequency oscillation and tracheal gas insufflation in patients with severe acute respiratory distress syndrome and traumatic brain injury: an interventional physiological study
    Vrettou, Charikleia S.
    Zakynthinos, Spyros G.
    Malachias, Sotirios
    Mentzelopoulos, Spyros D.
    CRITICAL CARE, 2013, 17 (04):
  • [4] Scanographic comparison of high frequency oscillation with versus without tracheal gas insufflation in acute respiratory distress syndrome
    Spyros D. Mentzelopoulos
    Maria Theodoridou
    Sotirios Malachias
    Sotiris Sourlas
    Demetrios N. Exarchos
    Demetrios Chondros
    Charis Roussos
    Spyros G. Zakynthinos
    Intensive Care Medicine, 2011, 37 : 990 - 999
  • [5] Scanographic comparison of high frequency oscillation with versus without tracheal gas insufflation in acute respiratory distress syndrome
    Mentzelopoulos, Spyros D.
    Theodoridou, Maria
    Malachias, Sotirios
    Sourlas, Sotiris
    Exarchos, Demetrios N.
    Chondros, Demetrios
    Roussos, Charis
    Zakynthinos, Spyros G.
    INTENSIVE CARE MEDICINE, 2011, 37 (06) : 990 - 999
  • [6] High-Frequency Oscillation for Acute Respiratory Distress Syndrome
    Young, Duncan
    Lamb, Sarah E.
    Shah, Sanjoy
    MacKenzie, Iain
    Tunnicliffe, William
    Lall, Ranjit
    Rowan, Kathy
    Cuthbertson, Brian H.
    NEW ENGLAND JOURNAL OF MEDICINE, 2013, 368 (09): : 806 - 813
  • [7] High-Frequency Oscillation in Early Acute Respiratory Distress Syndrome
    Ferguson, Niall D.
    Cook, Deborah J.
    Guyatt, Gordon H.
    Mehta, Sangeeta
    Hand, Lori
    Austin, Peggy
    Zhou, Qi
    Matte, Andrea
    Walter, Stephen D.
    Lamontagne, Francois
    Granton, John T.
    Arabi, Yaseen M.
    Arroliga, Alejandro C.
    Stewart, Thomas E.
    Slutsky, Arthur S.
    Meade, Maureen O.
    NEW ENGLAND JOURNAL OF MEDICINE, 2013, 368 (09): : 795 - 805
  • [8] High-frequency oscillation in acute respiratory distress syndrome (ARDS)
    McLuckie, A
    BRITISH JOURNAL OF ANAESTHESIA, 2004, 93 (03) : 322 - 324
  • [9] High-Frequency Oscillation in Acute Respiratory Distress Syndrome The End of the Story?
    Vincent, Jean-Louis
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 196 (06) : 670 - 671
  • [10] Efficacy of tracheal gas insufflation in acute respiratory distress syndrome with permissive hypercapnia
    Kuo, PH
    Wu, HD
    Yu, CJ
    Yang, SC
    Lai, YL
    Yang, PC
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (03) : 612 - 616