Time-lapse lab-based x-ray nano-CT study of corrosion damage

被引:21
|
作者
Bradley, R. S. [1 ,5 ]
Liu, Y. [2 ]
Burnett, T. L. [1 ,2 ]
Zhou, X. [2 ]
Lyon, S. B. [2 ]
Withers, P. J. [1 ,2 ]
Gholinia, A. [2 ]
Hashimoto, T. [2 ]
Graham, D. [3 ]
Gibbon, S. R. [3 ]
Hornberger, B. [4 ]
机构
[1] Univ Manchester, Henry Moseley Xray Imaging Facil, Manchester M13 9PL, Lancs, England
[2] Univ Manchester, Sch Mat, Manchester M13 9PL, Lancs, England
[3] AkzoNobel, Stoneygate Lane, Felling NE10 0JY, Gateshead, England
[4] Carl Zeiss Xray Microscopy, 4385 Hopyard Rd, Pleasanton, CA USA
[5] Geotek Ltd, Daventry NN11 8PB, Northants, England
基金
英国工程与自然科学研究理事会;
关键词
Computed tomography; paint; plasma focused ion beam (PFIB); primer coating; Zernike phase contrast; AA2024-T3; ALUMINUM-ALLOY; LOCALIZED CORROSION; TOMOGRAPHY; PROTECTION; MICROSCOPY; BEHAVIOR;
D O I
10.1111/jmi.12551
中图分类号
TH742 [显微镜];
学科分类号
摘要
An experimental protocol (workflow) has been developed for time-lapse x-ray nanotomography (nano-CT) imaging of environmentally driven morphological changes to materials. Two case studies are presented. First, the leaching of nanoparticle corrosion inhibitor pigment from a polymer coating was followed over 14 days, while in the second case the corrosion damage to an AA2099 aluminium alloy was imaged over 12 hours. The protocol includes several novel aspects relevant to nano-CT with the use of a combination of x-ray absorption and phase contrast data to provide enhanced morphological and composition information, and hence reveal the best information to provide new insights into the changes of different phases over time. For the pigmented polymer coating containing nominally strontium aluminium polyphosphate, the strontium-rich components within the materials are observed to leach extensively whereas the aluminium-rich components are more resistant to dissolution. In the case of AA2099 it is found that the initial grain boundary corrosion is driven by the presence of copper-rich phases and is then followed by the corrosion of grains of specific orientation. Lay Description Time lapse x-ray computed tomography enables the collection of sequences of 3-D images. Few experiments have been carried out to date at submicrometre resolutions. Here we use an in situ cell to study the environmentally induced changes of two materials exposed to saline conditions. The first is a primer coating used to protect metal materials and the other is an aluminium alloy used in airplane (AA2099 aluminium alloy). For the primer coating, we followed the release of corrosion inhibitor (strontium aluminium polyphosphate) nanoparticles for 14 days. Using phase contrast imaging we were able to discern the inhibitor particle morphologies whereas attenuation contrast distinguished strontium- and aluminium-rich particles. We found that the strontium-rich particles dissolved rapidly whereas the aluminium-rich components were more resistant to dissolution. In the case of aluminium aerospace alloy, we tracked the progress of intergranular corrosion being driven by the presence of copper-rich phases at the grain boundaries of the alloy. This was then followed by the rapid corrosion of particular grains.
引用
收藏
页码:98 / 106
页数:9
相关论文
共 50 条
  • [1] Time-lapse lab-based x-ray nano-CT study of corrosion damage
    Bradley, R.S.
    Liu, Y.
    Burnett, T.L.
    Zhou, X.
    Lyon, S.B.
    Withers, P.J.
    Gholinia, A.
    Hashimoto, T.
    Graham, D.
    Gibbon, S.R.
    Hornberger, B.
    Journal of Microscopy, 2017, 267 (01): : 98 - 106
  • [2] Complete Ring Artifacts Reduction Procedure for Lab-Based X-ray Nano CT Systems
    Salplachta, Jakub
    Zikmund, Tomas
    Zemek, Marek
    Brinek, Adam
    Takeda, Yoshihiro
    Omote, Kazuhiko
    Kaiser, Jozef
    SENSORS, 2021, 21 (01) : 1 - 20
  • [3] MICROMECHANICAL TIME-LAPSE X-RAY CT STUDY OF FATIGUE DAMAGE IN UNI-DIRECTIONAL FIBRE COMPOSITES
    Jespersen, Kristine M.
    Lowe, Tristan
    Withers, Philip J.
    Zangenberg, Jens
    Mikkelsen, Lars P.
    20TH INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS, 2015,
  • [4] In situ time-lapse synchrotron radiation X-ray diffraction of silver corrosion
    Wiesinger, Rita
    Grayburn, Rosie
    Dowsett, Mark
    Sabbe, Pieter-Jan
    Thompson, Paul
    Adriaens, Annemie
    Schreiner, Manfred
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (03) : 694 - 701
  • [5] Lab-based X-ray nanoCT imaging
    Muller, Mark
    Allner, Sebastian
    Ferstl, Simone
    Dierolf, Martin
    Tuohimaa, Tomi
    Pfeiffer, Franz
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [6] Image alignment for synchrotron radiation based X-ray nano-CT
    Su Bo
    Tao Fen
    Li Ke
    Du Guo-Hao
    Zhang Ling
    Li Zhong-Liang
    Deng Biao
    Xie Hong-Lan
    Xiao Ti-Qiao
    ACTA PHYSICA SINICA, 2021, 70 (16)
  • [7] TIME-LAPSE PHOTOGRAPHY OF X-RAY INHIBITION OF GROWTH
    LOWRY, WS
    LANCET, 1959, 1 (MAY23): : 1098 - 1098
  • [8] Time-Lapse Helical X-ray Computed Tomography (CT) Study of Tensile Fatigue Damage Formation in Composites for Wind Turbine Blades
    Wang, Ying
    Mikkelsen, Lars P.
    Pyka, Grzegorz
    Withers, Philip J.
    MATERIALS, 2018, 11 (11):
  • [9] Application of X-ray nano-CT fluoroscopy and fluorescence spectroscopy in the study of ancient bronzes
    Tan X.
    Nanotechnology for Environmental Engineering, 2022, 7 (04) : 965 - 972
  • [10] Positron annihilation and X-ray nano-CT to investigate nuclear materials
    Weber, Marc H.
    Karcher, Sam
    Bussey, John
    McCloy, John
    MRS ADVANCES, 2024, 9 (07) : 467 - 472