Dimensional Accuracy of Dental Models for Three-Unit Prostheses Fabricated by Various 3D Printing Technologies

被引:48
|
作者
Yoo, Soo-Yeon [1 ,2 ]
Kim, Seong-Kyun [1 ,2 ]
Heo, Seong-Joo [1 ,2 ]
Koak, Jai-Young [1 ,2 ]
Kim, Joung-Gyu [3 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dent Hosp, Dept Prosthodont, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Sch Dent, Dent Hosp, Dent Res Inst, 101 Daehak Ro, Seoul 03080, South Korea
[3] Sense Dent Lab, 1104 Seoul Soop IT Valley,77 Seongsuil Ro, Seoul 04790, South Korea
基金
新加坡国家研究基金会;
关键词
3D printing; digital light processing (DLP); multi-jet printing (MJP); stereo-lithography apparatus (SLA); dimensional accuracy; PRECISION; SHRINKAGE; PLASTER; ERROR;
D O I
10.3390/ma14061550
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Previous studies on accuracy of three-dimensional (3D) printed model focused on full arch measurements at few points. The aim of this study was to examine the dimensional accuracy of 3D-printed models which were teeth-prepped for three-unit fixed prostheses, especially at margin and proximal contact areas. The prepped dental model was scanned with a desktop scanner. Using this reference file, test models were fabricated by digital light processing (DLP), Multi-Jet printing (MJP), and stereo-lithography apparatus (SLA) techniques. We calculated the accuracy (trueness and precision) of 3D-printed models on 3D planes, and deviations of each measured points at buccolingual and mesiodistal planes. We also analyzed the surface roughness of resin printed models. For overall 3D analysis, MJP showed significantly higher accuracy (trueness) than DLP and SLA techniques; however, there was not any statistically significant difference on precision. For deviations on margins of molar tooth and distance to proximal contact, MJP showed significantly accurate results; however, for a premolar tooth, there was no significant difference between the groups. 3D color maps of printed models showed contraction buccolingually, and surface roughness of the models fabricated by MJP technique was observed as the lowest. The accuracy of the 3D-printed resin models by DLP, MJP, and SLA techniques showed a clinically acceptable range to use as a working model for manufacturing dental prostheses
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Comparison of Accuracy of Fit of Three-Unit Fixed Ceramic Cobalt-Chromium Dental Prostheses Fabricated by Three Different Techniques
    Daou, Elie E.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (05) : 642 - 649
  • [2] Accuracy of 3-unit fixed dental prostheses fabricated on 3D-printed casts
    Jang, Yeon
    Sim, Ji-Young
    Park, Jong-Kyoung
    Kim, Woong-Chul
    Kim, Hae-Young
    Kim, Ji-Hwan
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 135 - 142
  • [3] Accuracy evaluation of complete-arch models manufactured by three different 3D printing technologies: a three-dimensional analysis
    Emir, Faruk
    Ayyildiz, Simel
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (03) : 365 - 370
  • [4] Fracture Load of 3D-Printed Interim Three-Unit Fixed Dental Prostheses: Impact of Printing Orientation and Post-Curing Time
    Alkhateeb, Reem I. I.
    Algaoud, Hadeel S. S.
    Aldamanhori, Rand B. B.
    Alshubaili, Rand R. R.
    Alalawi, Haidar
    Gad, Mohammed M. M.
    POLYMERS, 2023, 15 (07)
  • [5] Influence of Sequential CAD/CAM Milling on the Fitting Accuracy of Titanium Three-Unit Fixed Dental Prostheses
    Song, Doo-Bin
    Han, Man-So
    Kim, Si-Chul
    Ahn, Junyong
    Im, Yong-Woon
    Lee, Hae-Hyoung
    MATERIALS, 2021, 14 (06)
  • [6] Digital measurement method for comparing the absolute marginal discrepancy of three-unit ceramic fixed dental prostheses fabricated using conventional and digital technologies
    Liang, Shanshan
    Yuan, Fusong
    Li, Deli
    Jia, Lu
    Sun, Yuchun
    BMC ORAL HEALTH, 2023, 23 (01)
  • [7] Digital measurement method for comparing the absolute marginal discrepancy of three-unit ceramic fixed dental prostheses fabricated using conventional and digital technologies
    Shanshan Liang
    Fusong Yuan
    Deli Li
    Lu Jia
    Yuchun Sun
    BMC Oral Health, 23
  • [8] An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system
    Kim, Ki-Baek
    Kim, Woong-Chul
    Kim, Hae-Young
    Kim, Ji-Hwan
    DENTAL MATERIALS, 2013, 29 (07) : E91 - E96
  • [9] Three-dimensional comparative study on the accuracy and reproducibility of dental casts fabricated by 3D printers
    Park, Mid-Eum
    Shin, Soo-Yeon
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (05): : 861.e1 - 861.e7
  • [10] Accuracy Comparison among 3D-Printing Technologies to Produce Dental Models
    Kim, Jun Ho
    Pinhata-Baptista, Otavio Henrique
    Ayres, Ana Paula
    Berbel da Silva, Renan Lucio
    Lima, Jacqueline Ferreira
    Urbano, Gabriel Sardinha
    No-Cortes, Juliana
    Vasques, Mayra Torres
    Gonzalez Cortes, Arthur Rodriguez
    APPLIED SCIENCES-BASEL, 2022, 12 (17):