Film dosimetry studies for patient specific quality assurance in microbeam radiation therapy

被引:17
|
作者
Ocadiz, Alexandre [1 ]
Livingstone, Jayde [2 ]
Donzelli, Mattia [3 ,4 ]
Bartzsch, Stefan [5 ]
Nemoz, Christian [3 ]
Kefs, Samy [7 ]
Pellicioli, Paolo [1 ,3 ,6 ]
Giraud, Jean-Yves [1 ,7 ]
Balosso, Jacques [1 ,7 ]
Krisch, Michael [3 ]
Brauer-Krisch, Elke [3 ]
Serduc, Raphael [1 ]
Adam, Jean-Francois [1 ,7 ]
机构
[1] Univ Grenoble Alpes, INSERM STROBE UA7, Grenoble, France
[2] Australian Synchrotron, Imaging & Med Beamline, Melbourne, Vic, Australia
[3] European Synchrotron Radiat Facil, ID17, Grenoble, France
[4] Inst Canc Res, London, England
[5] Tech Univ Munich, Klinikum Rechts Isar, Dept Radiat Oncol, Munich, Germany
[6] Swansea Univ, Swansea, W Glam, Wales
[7] Grenoble Alper Univ Hosp CHU GA, Grenoble, France
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 65卷
关键词
Film dosimetry; Microbeam radiation therapy; Quality assurance; FORTHCOMING CLINICAL-TRIALS; STEREOTACTIC RADIOTHERAPY; MICROPLANAR BEAM; PROTOCOL; MRT;
D O I
10.1016/j.ejmp.2019.09.071
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Microbeam radiation therapy (MRT) uses synchrotron arrays of X-ray microbeams to take advantage of the spatial fractionation effect for normal tissue sparing. In this study, radiochromic film dosimetry was performed for a treatment where MRT is introduced as a dose boost in a hypofractionated stereotactic radiotherapy (SRT) scheme. The isocenter dose was measured using an ionization chamber and two dimensional dose distributions were determined using radiochromic films. To compare the measured dose distribution to the MRT treatment plan, peak and valley were displayed in separate dosemaps. The measured and computed isocenter doses were compared and a two-dimensional 2%/2 mm normalized gamma-index analysis with a 90% passing rate criterion was computed. For SRT, a difference of 2.6% was observed in the dose at the isocenter from the treatment plan and film measurement, with a passing rate of 96% for the gamma-index analysis. For MRT, peak and valley doses differences of 25.6% and 8.2% were observed, respectively but passing rates of 96% and 90% respectively were obtained from the normalized gamma-index maps. The differences in isocenter doses measured in MRT should be further investigated. We present the methodology of patient specific quality assurance (QA) for studying MRT dose distributions and discuss ideas to improve absolute dosimetry. This patient specific QA will be used for large animal trials quality assurance where MRT will be administered as a dose boost in conventional SRT. The observed remaining discrepancies should be studied against approximations in the TPS phantom materials, beams characteristics or film read-out procedures.
引用
收藏
页码:227 / 237
页数:11
相关论文
共 50 条
  • [1] Thermoluminescence dosimetry for quality assurance in radiation therapy
    Kalef-Ezra, JA
    Boziari, A
    Litsas, J
    Tsekeris, P
    Koligliatis, T
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A403 - A405
  • [2] Thermoluminescence dosimetry for quality assurance in radiation therapy
    Kalef-Ezra, JA
    Boziari, A
    Litsas, J
    Tsekeris, P
    Koligliatis, T
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 403 - 405
  • [3] Patient Specific Quality Assurance of IMRT: Quantitative Approach Using Film Dosimetry and Optimization
    Shin, Kyung Hwan
    Park, Sung-Yong
    Park, Dong Hyun
    Shin, Dongho
    Park, Dahl
    Kim, Tae Hyun
    Pyo, Hongryull
    Kim, Joo-Young
    Kim, Dae Yong
    Cho, Kwan Ho
    Huh, Sun Nyung
    Kim, Il Han
    Park, Charn Il
    RADIATION ONCOLOGY JOURNAL, 2005, 23 (03): : 176 - 185
  • [4] Challenges in Radiochromic Film Dosimetry Applied to Microbeam Radiation Therapy (MRT)
    Anderson, D.
    Warkentin, B.
    Siegbahn, E. A.
    Fallone, B. G.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [5] Comparison of film dosimetry techniques used for quality assurance of intensity modulated radiation therapy
    Ju, Sang Gyu
    Han, Youngyih
    Kum, Oyeon
    Cheong, Kwang-Ho
    Shin, Eun Hyuk
    Shin, Jung Suk
    Kim, Jin Sung
    Ahn, Yong Chan
    MEDICAL PHYSICS, 2010, 37 (06) : 2925 - 2933
  • [6] Comparison of phantom materials for use in quality assurance of microbeam radiation therapy
    Cameron, Matthew
    Cornelius, Iwan
    Cutajar, Dean
    Davis, Jeremy
    Rosenfeld, Anatoly
    Lerch, Michael
    Guatelli, Susanna
    JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 : 866 - 876
  • [7] Micrometer-resolved film dosimetry using a microscope in microbeam radiation therapy
    Bartzsch, Stefan
    Lott, Johanna
    Welsch, Katrin
    Braeuer-Krisch, Elke
    Oelfke, Uwe
    MEDICAL PHYSICS, 2015, 42 (07) : 4069 - 4079
  • [8] Quality assurance of patient dosimetry in boron neutron capture therapy
    af Rosenschöld, PMM
    Capala, J
    Ceberg, CP
    Giusti, V
    Salford, LG
    Persson, BRR
    ACTA ONCOLOGICA, 2004, 43 (04) : 404 - 411
  • [9] Implementation of An In-House Radiochromic Film Dosimetry Software for Patient Specific Treatment Plan Quality Assurance
    Schurr, R.
    Park, J.
    Kim, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2954 - 2955
  • [10] Patient specific quality assurance in proton therapy
    Amos, R.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S3 - S3