IR and UV gas absorption measurements during NOx reduction on an industrial natural gas fired power plant

被引:30
|
作者
Stamate, E. [1 ]
Chen, W. [1 ]
Jorgensen, L. [2 ]
Jensen, T. K. [2 ]
Fateev, A. [1 ]
Michelsen, P. K. [1 ]
机构
[1] Tech Univ Denmark, Plasma Phys & Technol Programme, Riso Natl Lab Sustainable Energy, DK-4000 Roskilde, Denmark
[2] Danish Gas Technol Ctr, DK-2970 Horsholm, Denmark
关键词
NOx removal; Ozone oxidation; FTIR; UV absorption spectroscopy; Chemical kinetics; OZONE INJECTION; SIMULTANEOUS REMOVAL; PULSED-CORONA; SO2; N2O5;
D O I
10.1016/j.fuel.2009.11.044
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
NOx reduction of flue gas by plasma-generated ozone was investigated in pilot test experiments on an industrial power plant running on natural gas. Reduction rates higher than 95% have been achieved for a molar ratio O-3:NOx slightly below two. Fourier transform infrared and ultraviolet absorption spectroscopy were used for spatial measurements of stable molecules and radicals along the reduction reactor. Reactions of O3 injected in the flue gas in the reduction reactor were also modeled. Experiments are in good agreement with numerical simulations. The operation costs for NOx reduction were estimated based on field tests measurements. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:978 / 985
页数:8
相关论文
共 50 条
  • [1] The natural hedge of a gas-fired power plant
    Guo X.
    Beskos A.
    Siddiqui A.
    Computational Management Science, 2016, 13 (1) : 63 - 86
  • [2] ADDING A BIOMASS-FIRED COGENERATION POWER PLANT TO A NATURAL GAS PROCESSING PLANT
    McCann, Derek
    J-FOR-JOURNAL OF SCIENCE & TECHNOLOGY FOR FOREST PRODUCTS AND PROCESSES, 2012, 2 (02): : 40 - 43
  • [3] ADDING A BIOMASS-FIRED COGENERATION POWER PLANT TO A NATURAL GAS PROCESSING PLANT
    McCann, Derek
    PULP & PAPER-CANADA, 2013, 114 (05) : 28 - 31
  • [4] Adding a biomass-fired cogeneration power plant to a natural gas processing plant
    McCann, Derek
    Pulp and Paper Canada, 2013, 114 (05): : 28 - 31
  • [5] NOX REDUCTION IN A GAS FIRED UTILITY BOILER BY COMBUSTION MODIFICATIONS
    BULLIN, JA
    WILKERSON, D
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1982, 32 (06): : 669 - 672
  • [6] Indirect NOx emission monitoring in natural gas fired boilers
    Korpela, Timo
    Kumpulainen, Pekka
    Majanne, Yrjo
    Hayrinen, Anna
    Lautala, Pentti
    CONTROL ENGINEERING PRACTICE, 2017, 65 : 11 - 25
  • [7] COMBUSTION OF NATURAL-GAS IN A POWER-PLANT PREVIOUSLY FIRED BY COAL
    WAGNER, F
    BRENNSTOFF-WARME-KRAFT, 1972, 24 (05): : 205 - &
  • [8] Experiences with a new burner type for NOx reduction in the Block One gas-fired steam generator at the Moorburg Power Plant
    Zimmermann, B
    Schreier, W
    COMBUSTION AND INCINERATION - EIGHTEENTH DUTCH-GERMAN CONFERENCE ON FLAMES, 1997, 1313 : 27 - 32
  • [9] NATURAL GAS AS FUEL IN INDUSTRIAL PLANT
    UPMALIS, A
    BRENNSTOFF-WARME-KRAFT, 1969, 21 (11): : 568 - &
  • [10] NOX REDUCTION WITH RESPECT TO INDUSTRIAL GAS-BURNERS
    FLAMME, M
    KREMER, H
    BECKERVORDERSANDFORTH, CP
    ERDOL & KOHLE ERDGAS PETROCHEMIE, 1989, 42 (09): : 353 - 360