Calibration and evaluation of optical systems for full-field strain measurement

被引:58
|
作者
Patterson, Eann A.
Hack, Erwin
Brailly, Philippe
Burguete, Richard L.
Saleem, Qasim
Siebert, Thorsten
Tomlinson, Rachel A.
Whelan, Maurice P.
机构
[1] Michigan State Univ, Dept Mech Engn, E Lansing, MI 48824 USA
[2] EMPA Lab Elect Metrol, Dubendorf, Switzerland
[3] Univ Sheffield, Dept Mech Engn, Sheffield, S Yorkshire, England
[4] Commiss European Communities, Inst Hlth & Consumer Protect, DG Joint Res Ctr, Ispra, Italy
关键词
optical measurement; strain; reference material; standardized test material;
D O I
10.1016/j.optlaseng.2006.08.012
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The design and testing of a reference material for the calibration of optical systems for strain measurement is described, together with the design and testing of a standardized test material that allows the evaluation and assessment of fitness for purpose of the most sophisticated optical system for strain measurement. A classification system for the steps in the measurement process is also proposed and allows the development of a unified approach to diagnostic testing of components or sub-systems in an optical system for strain measurement based on any optical technique. The results described arise from a European study known as SPOTS whose objectives were to begin to fill the gap caused by a lack of standards. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:550 / 564
页数:15
相关论文
共 50 条
  • [1] On the calibration of optical full-field strain measurement systems
    Whelan, M.
    Hack, E.
    Siebert, T.
    Burguete, R.
    Patterson, E. A.
    Saleem, Q.
    Advances in Experimental Mechanics IV, 2005, 3-4 : 397 - 402
  • [2] Calibration and assessment of full-field optical strain measurement procedures and instrumentation
    Kujawinska, Malgorzata
    Patterson, E. A.
    Burguete, R.
    Hack, E.
    Mendels, D.
    Siebert, T.
    Whelan, Maurice
    SPECKLE06: SPECKLES, FROM GRAINS TO FLOWERS, 2006, 6341
  • [3] Calibration of a speckle interferometry full-field strain measurement system
    Whelan, M. P.
    Albrecht, D.
    Hack, E.
    Patterson, E. A.
    STRAIN, 2008, 44 (02) : 180 - 190
  • [4] Load and Boundary Condition Calibration Using Full-field Strain Measurement
    S. Padmanabhan
    J. P. Hubner
    A. V. Kumar
    P. G. Ifju
    Experimental Mechanics, 2006, 46 : 569 - 578
  • [5] Load and boundary condition calibration using full-field strain measurement
    Padmanabhan, S.
    Hubner, J. P.
    Kumar, A. V.
    Ifju, P. G.
    EXPERIMENTAL MECHANICS, 2006, 46 (05) : 569 - 578
  • [6] The development of a reference material for calibration of full-field optical measurement systems for dynamic deformation measurements
    Davighi, Andrea
    Burquete, Richard
    Feligiotti, Mara
    Hack, Erwin
    James, Simon
    Patterson, Eann
    Siebert, Thorsten
    Whelan, Maurice
    ADVANCES IN EXPERIMENTAL MECHANICS VIII, 2011, 70 : 33 - +
  • [7] Development of standard measurement chain for full-field optical strain measurement methods
    Salbut, L
    Kujawinska, M
    Patterson, E
    Hack, E
    Burguete, R
    Whelan, M
    Mendels, DA
    INTERFEROMETRY XII: APPLICATIONS, 2004, 5532 : 268 - 277
  • [8] Assessment of a dynamic reference material for calibration of full-field measurement systems
    Hack, Erwin
    Feligiotti, Mara
    Davighi, Andrea
    Whelan, Maurice
    Wang, Weizhuo Victor
    Patterson, Eann A.
    SPECKLE 2012: V INTERNATIONAL CONFERENCE ON SPECKLE METROLOGY, 2012, 8413
  • [9] Optical full-field strain measurement within a diamond anvil cell
    Freville, Robin
    Bruzy, Nicolas
    Dewaele, Agnes
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (12):
  • [10] Optical full-field measurement of strain at a microscopic scale with the grid method
    Moulart, Raphael
    Rotinat, Rene
    Pierron, Fabrice
    Lerondel, Gilles
    Royer, Pascal
    SPECKLE06: SPECKLES, FROM GRAINS TO FLOWERS, 2006, 6341