Open-source, vendor-independent, automated multi-beat tissue Doppler echocardiography analysis

被引:11
|
作者
Dhutia, Niti M. [1 ]
Zolgharni, Massoud [1 ]
Mielewczik, Michael [1 ]
Negoita, Madalina [1 ]
Sacchi, Stefania [1 ]
Manoharan, Karikaran [1 ]
Francis, Darrel P. [1 ]
Cole, Graham D. [1 ]
机构
[1] Imperial Coll London, Natl Heart & Lung Inst, Hammersmith Hosp Campus,Du Cane Rd, London W12 0NN, England
来源
基金
欧洲研究理事会;
关键词
Tissue Doppler; Echocardiography; Automated; Vendor-independent measurements; Myocardial velocities; VENTRICULAR DIASTOLIC FUNCTION; EUROPEAN ASSOCIATION; AMERICAN-SOCIETY; PROGNOSTIC VALUE; RECOMMENDATIONS;
D O I
10.1007/s10554-017-1092-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Current guidelines for measuring cardiac function by tissue Doppler recommend using multiple beats, but this has a time cost for human operators. We present an open-source, vendor-independent, drag-and-drop software capable of automating the measurement process. A database of similar to 8000 tissue Doppler beats (48 patients) from the septal and lateral annuli were analyzed by three expert echocardiographers. We developed an intensity- and gradient-based automated algorithm to measure tissue Doppler velocities. We tested its performance against manual measurements from the expert human operators. Our algorithm showed strong agreement with expert human operators. Performance was indistinguishable from a human operator: for algorithm, mean difference and SDD from the mean of human operators' estimates 0.48 +/- 1.12 cm/s (R-2 = 0.82); for the humans individually this was 0.43 +/- 1.11 cm/s (R-2 = 0.84), -0.88 +/- 1.12 cm/s (R-2 = 0.84) and 0.41 +/- 1.30 cm/s (R-2 = 0.78). Agreement between operators and the automated algorithm was preserved when measuring at either the edge or middle of the trace. The algorithm was 10-fold quicker than manual measurements (p < 0.001). This open-source, vendor-independent, drag-and-drop software can make peak velocity measurements from pulsed wave tissue Doppler traces as accurately as human experts. This automation permits rapid, bias-resistant multi-beat analysis from spectral tissue Doppler images.
引用
收藏
页码:1135 / 1148
页数:14
相关论文
共 50 条
  • [1] Open-source, vendor-independent, automated multi-beat tissue Doppler echocardiography analysis
    Niti M. Dhutia
    Massoud Zolgharni
    Michael Mielewczik
    Madalina Negoita
    Stefania Sacchi
    Karikaran Manoharan
    Darrel P. Francis
    Graham D. Cole
    The International Journal of Cardiovascular Imaging, 2017, 33 : 1135 - 1148
  • [2] Automated multi-beat tissue Doppler echocardiography analysis using deep neural networks
    Elisabeth S. Lane
    Jevgeni Jevsikov
    Matthew J. Shun-shin
    Niti Dhutia
    Nasser Matoorian
    Graham D. Cole
    Darrel P. Francis
    Massoud Zolgharni
    Medical & Biological Engineering & Computing, 2023, 61 : 911 - 926
  • [3] Automated multi-beat tissue Doppler echocardiography analysis using deep neural networks
    Lane, Elisabeth S.
    Jevsikov, Jevgeni
    Shun-shin, Matthew J.
    Dhutia, Niti
    Matoorian, Nasser
    Cole, Graham D.
    Francis, Darrel P.
    Zolgharni, Massoud
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2023, 61 (05) : 911 - 926
  • [4] Frame rate required for speckle tracking echocardiography: A quantitative clinical study with open-source, vendor-independent software
    Negoita, Madalina
    Zolgharni, Massoud
    Dadkho, Elham
    Pernigo, Matteo
    Mielewczik, Michael
    Cole, Graham D.
    Dhutia, Niti M.
    Francis, Darrel P.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 218 : 31 - 36
  • [5] Open-source software for automated rodent behavioral analysis
    Isik, Sena
    Unal, Gunes
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [6] MOST: An open-source, vendor and technology independent toolkit for building monitoring, data preprocessing, and visualization
    Zach, R.
    Glawischnig, S.
    Hoenisch, M.
    Appel, R.
    Mahdavi, A.
    EWORK AND EBUSINESS IN ARCHITECTURE, ENGINEERING AND CONSTRUCTION, 2012, : 97 - 103
  • [7] Guidance for accurate and consistent tissue Doppler velocity measurement: comparison of echocardiographic methods using a simple vendor-independent method for local validation
    Dhutia, Niti M.
    Zolgharni, Massoud
    Willson, Keith
    Cole, Graham
    Nowbar, Alexandra N.
    Dawson, David
    Zielke, Sayeh
    Whelan, Carol
    Newton, Jim
    Mayet, Jamil
    Manisty, Charlotte H.
    Francis, Darrel P.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (07) : 817 - 827
  • [8] VISION - an open-source software for automated multi-dimensional image analysis of cellular biophysics
    Weber, Florian
    Iskrak, Sofiia
    Ragaller, Franziska
    Schlegel, Jan
    Plochberger, Birgit
    Sezgin, Erdinc
    Andronico, Luca A.
    JOURNAL OF CELL SCIENCE, 2024, 137 (20)
  • [9] EyeNED workstation: Development of a multi-modal vendor-independent application for annotation, spatial alignment and analysis of retinal images
    van Zeeland, Harm
    Meakin, James
    Liefers, Bart
    Gonzalez-Gonzalo, Cristina
    Vaidyanathan, Akshayaa
    van Ginneken, Bram
    Klaver, Caroline C. W.
    Sanchez, Clara I.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [10] An Automated Aerodynamic Analysis System in Missile Based on Open-Source Software
    Kang Kuk You
    Jung Hyun Ha
    Sang Chul Lee
    International Journal of Aeronautical and Space Sciences, 2023, 24 : 592 - 605